{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C11R4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C11R4","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C11R4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C11R4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, modular variable speed drive, ATV9A0C11R4, 110 kW at 440 V normal duty, 90 kW heavy duty, IP00.","salesMarkdown":"The ATV9A0C11R4: The normal-duty 110 kW rating is the headline number for centrifugal pumps and fans where overload is minimal. The heavy-duty 90 kW rating governs constant-torque loads like conveyors or extruders — that 183 A line current at 440 V normal duty drops to 155 A for heavy duty, so sizing the input wiring and fusing for the heavy-duty current ensures the drive can deliver its rated torque without nuisance tripping. The integrated EMC filter is rated for 300 m of motor cable per IEC 61800-3 category C3 — enough for most industrial installations without an external filter. The IP00 enclosure means the drive lives inside a cabinet rated IP21 or IP54. ## Integration Notes The modular version ships as a kit: power module, control unit, mechanical mounting kit, and power connection set of fuses. The control block carries two RJ45 for Ethernet IP/Modbus TCP and one RJ45 for Modbus serial (RS-485, 2-wire, RTU, 4.8 to 38.4 kbit/s). Supply voltages: 24 V DC (19...30 V) for digital inputs, a separate 24 V DC (21...27 V) for digital inputs and STO, and a 10.5 V DC reference for a 1 to 10 kOhm potentiometer. The line-side connection uses screw terminals; motor connection uses M10 bars.","metaTitle":"Schneider ATV9A0C11R4 Altivar Process Drive, 110 kW Normal D","metaDescription":"Schneider ATV9A0C11R4 Altivar Process ATV900 drive, 110 kW at 440 V normal duty, STO SIL 3, integrated EMC filter, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"183.0 A at 440 V (normal duty) 155.0 A at 440 V (heavy duty)","Frequency":"50...60 Hz +/- 5 %","Data Format":"8 bits, configurable odd, even or no parity for Modbus serial","Connector Type":"2 RJ45 for Ethernet IP/Modbus TCP on the control block 1 RJ45 for Modbus serial on the control block","Product Status":"Active","Pollution Degree":"2 conforming to IEC 61800-5-1","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.2 °C","Temperature Storage":"-40...70 °C","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV9A0C11R4/variable-speed-drive-altivar-process-atv900-apm-single-440-v-110-kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C11R4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C11R4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C11R4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}