{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C20Q4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C20Q4","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C20Q4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C20Q4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, modular drive, ATV9A0C20Q4, 200 kW normal duty / 160 kW heavy duty at 400 V, STO SIL 3, integrated EMC filter.","salesMarkdown":"## Drive ratings and duty selection The Schneider ATV9A0C20Q4 is a modular Altivar Process ATV900 drive rated 200 kW at 400 V normal duty and 160 kW at 400 V heavy duty. Line current draws 352 A under normal duty, 290 A under heavy duty. Apparent power is 244 kVA normal duty, 201 kVA heavy duty. The heavy-duty figure governs continuous motor overload capability — size the drive to the motor's full-load amps and the application's overload profile, not the ND number. ## Safety and EMC The integrated EMC filter is rated for 300 m of motor cable in C3 environments per IEC 61800-3. For longer cable runs or C2 compliance, an external output filter is needed. ## Switching frequency and derating Switching frequency adjustable from 2 to 8 kHz, with derating above 2.5 kHz. Higher switching reduces audible noise (rated 70 dB) but increases drive losses — the 2.5 kHz default is the thermal baseline; expect current derating if you push to 8 kHz. ## Option card slots and fieldbus Three slots (A, B, C) accept communication modules for Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen, plus digital/analog I/O and relay extensions. Slot A also takes encoder interface modules (digital 5/12 V, analog, resolver). The control block includes dual RJ45 for Ethernet IP/Modbus TCP and one RJ45 for Modbus serial (RS-485, 2-wire, RTU). Cabinet mount, IP00 (requires IP21 or IP54 enclosure). Operates at 0 to 4800 m with current derating above 1000 m. Ambient humidity 5 to 95% non-condensing. Shock rated 7 gn for 11 ms; vibration 1.5 mm peak-to-peak at 2–13 Hz, 0.5 gn at 13–200 Hz.","metaTitle":"Schneider ATV9A0C20Q4 Altivar Process ATV900 Drive, 200 kW N","metaDescription":"Schneider Electric ATV9A0C20Q4 Altivar Process ATV900 drive, 200 kW normal duty / 160 kW heavy duty at 400 V. Active lifecycle, STO SIL 3, integrated EMC filter. Sourced to order a","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"352.0 A at 400 V (normal duty) 290.0 A at 400 V (heavy duty)","Frequency":"50...60 Hz +/- 5 %","Data Format":"8 bits, configurable odd, even or no parity for Modbus serial","Connector Type":"2 RJ45 for Ethernet IP/Modbus TCP on the control block 1 RJ45 for Modbus serial on the control block","Product Status":"Active","Pollution Degree":"2 conforming to IEC 61800-5-1","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.2 °C","Temperature Storage":"-40...70 °C","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV9A0C20Q4/variable-speed-drive-altivar-process-atv900-apm-single-400-v-200-kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C20Q4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C20Q4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C20Q4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}