{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C20T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C20T6","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C20T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C20T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, ATV9A0C20T6, modular variable speed drive, 200 hp at 600 V normal duty, 175 hp heavy duty, integrated EMC filter C3, STO SIL3.","salesMarkdown":"## Drive specs that matter for the BOM line The ATV9A0C20T6: It handles both synchronous and asynchronous motors and ships with an integrated EMC filter rated for 300 m cable runs to IEC 61800-3 category C3 – that means you can skip an external filter for most installations. STO (safe torque off) SIL3 is built in. ## Cabinet integration and wiring Cabinet-mount only, forced convection cooling – keep ventilation clear. Control connections use removable screw terminals (0.5…1.5 mm² / AWG 20…16). Line side uses screw terminals, motor bars are M10. Slot A accepts communication modules: Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen daisy chain or SUB-D. Slots A/B/C also accept digital/analog I/O extension and output relay modules. Slot B offers encoder interfaces (digital 5/12 V, analog, resolver). No fieldbus card is pre-installed – factor that into your order if you need Profinet or Ethernet/IP. Supply for digital inputs is external 24 V DC (19…30 V). A separate 10.5 V DC supply (±5%) for a reference pot (1…10 kΩ) and another 24 V DC supply (21…27 V) for digital inputs and STO are generated internally. Watch the 24 V rail for STO – it's isolated and voltage specific. IP00 from the factory – intended for IP21 or IP54 cabinet integration. Degree of protection UL type 1 and type 12 when properly housed. Current-production drive (lifecycle stage: current). Send an RFQ with quantity and target lead time for a competitive quote. Marked CE, meets IEC 61800-3, 61800-5-1, 61000-3-12, 60721-3, 61508, 13849-1, and UL 61800-5-1. Pollution degree 2 per IEC 61800-5-1. Noise level 69 dB (86/188/EEC). Vibration tested: 1.5 mm pk-pk at 2…13 Hz, 0.5 gn at 13…200 Hz; shock 4 gn, 11 ms.","metaTitle":"Schneider ATV9A0C20T6 200HP VFD, 600V","metaDescription":"Current-production Altivar Process ATV900 VFD: 200 hp at 600 V normal duty, 175 hp heavy duty. Integrated EMC filter C3, STO SIL3, cabinet mount. CE, UL 61800-5-1. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV9A0C20T6","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"69 dB 86/188/EEC","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module","description":"Variable speed drive, Altivar Process ATV900, APM, single 600 V, 200 hp","Line current":"172.0 A 600 V normal duty) 152.0 A 600 V heavy duty)","Maximum THDI":"<48 % from 80...100 % of load","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"179.0 kVA at 600 V normal duty 158.0 kVA at 600 V heavy duty","Motor power hp":"200.0 hp at 600 V normal duty 175.0 hp at 600 V heavy duty","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"215.0 A at 2.5 kHz normal duty 175.0 A at 2.5 kHz heavy duty","Maximum transient current":"258.0 A 60 s normal duty) 262.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"600 V - 10...15 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV9A0C20T6/variable-speed-drive-altivar-process-atv900-apm-single-600-v-200-hp/"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"Motor power: 200 hp at 600 V normal duty, 175 hp heavy duty. Apparent power: 179 kVA normal, 158 kVA heavy. Line current: 172 A normal, 152 A heavy. Switching frequency adjustable 2…4.9 kHz."},{"question":"What communication options does it support?","answer":"The drive has a Slot A for optional communication modules: Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen (daisy chain or SUB-D). Built-in serial is Modbus RTU (RS-485, 2-wire, 4.8…38.4 kbit/s) and Ethernet IP/Modbus TCP (10/100 Mbit/s)."},{"question":"What are the supply voltage requirements for control?","answer":"Digital inputs require an external 24 V DC supply (19…30 V). The drive provides an internal 10.5 V DC ±5 % for a reference potentiometer and an internal 24 V DC (21…27 V) for digital inputs and STO."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C20T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C20T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}