{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C40Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C40Q6","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C40Q6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C40Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Altivar Process ATV900, ATV9A0C40Q6, modular drive 400 kW at 690 V normal duty, 315 kW heavy duty, integrated EMC C3, STO SIL3.","salesMarkdown":"## Altivar Process ATV900 drive for 690 V heavy-duty applications The ATV9A0C40Q6 is a modular Altivar Process ATV900 drive from Schneider, rated 400 kW at 690 V for normal duty and 315 kW for heavy duty, with an integrated EMC filter meeting IEC 61800-3 category C3 and safe torque off (STO) to SIL3. It handles synchronous and asynchronous motors, with a switching frequency adjustable from 2 to 4.9 kHz and a line current of 394 A normal duty or 316 A heavy duty at 690 V. The heavy duty motor power (315 kW at 690 V) defines continuous capability for constant-torque loads like conveyors or extruders; the normal duty rating (400 kW) applies to variable-torque loads such as pumps and fans. Line current at heavy duty (316 A) dictates the upstream breaker and cable cross-section; the prospective line Isc of 50 kA means the drive can be installed on supply networks with high fault current capacity. The integrated EMC filter is rated for 300 m cable at C3 (second environment, industrial), so no external filter is needed for most industrial installations—saves panel space and wiring. STO SIL3 is built in, eliminating the need for a separate safety relay for torque-off functions. It is paired with thermal protection for both motor and drive, plus phase-loss and overcurrent detection. ## Supply and control wiring The drive expects an external 24 V DC supply for digital inputs (19 to 30 V), and generates internal 10.5 V for a reference potentiometer (1 to 10 kOhm) and 24 V for digital inputs and STO logic. Control connections are via removable screw terminals (0.5 to 1.5 mm², AWG 20 to 16), with line and motor connections on M10 bars. Built-in Modbus serial (RS-485, RTU) and Ethernet IP/Modbus TCP (10/100 Mbit/s) provide fieldbus connectivity; option slots accept Profibus DP, PROFINET, EtherCAT, DeviceNet, CANopen, and I/O extension modules. The drive carries CE marking and complies with IEC 61800-3, 61800-5-1, 61000-3-12, 60721-3, 61508, and 13849-1. The variant is modular, supplied as a kit including control unit, mounting hardware, fuses, and a 200 kW power module.","metaTitle":"Schneider ATV9A0C40Q6 Altivar Process ATV900, 400 kW at 690","metaDescription":"Active production Altivar Process ATV900 drive, 400 kW normal / 315 kW heavy duty at 690 V, integrated EMC C3, STO SIL3. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV9A0C40Q6","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"70 dB 86/188/EEC","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module","description":"Variable speed drive, Altivar Process ATV900, APM, single 690 V, 400 kW","Line current":"394.0 A 690 V normal duty) 316.0 A 690 V heavy duty)","Maximum THDI":"<48 % from 80...100 % of load","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"471.0 kVA at 690 V normal duty 378.0 kVA at 690 V heavy duty","Motor power kW":"400.0 kW at 690 V normal duty 315.0 kW at 690 V heavy duty","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 2.0 power module 200 kW 1 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"425.0 A at 2.5 kHz normal duty 340.0 A at 2.5 kHz heavy duty","Maximum transient current":"510.0 A 60 s normal duty) 510.0 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"690 V - 10...15 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV9A0C40Q6/variable-speed-drive-altivar-process-atv900-apm-single-690-v-400-kw/"},"ai":{"faq":[{"question":"What are the supply voltage requirements for the control circuitry?","answer":"Digital inputs use an external 24 V DC supply (19 to 30 V). Internal supplies provide 10.5 V DC for a reference potentiometer and 24 V DC for digital inputs and STO logic."},{"question":"What safety function does this drive support?","answer":"It includes safe torque off (STO) rated to SIL3, eliminating the need for an external safety relay for torque-off applications."},{"question":"What EMC compliance does the integrated filter provide?","answer":"The integrated EMC filter meets IEC 61800-3 category C3 for second environment (industrial), supporting cable lengths up to 300 m without an external filter."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C40Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C40Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}