{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C40T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C40T6","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C40T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C40T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, ATV9A0C40T6, modular drive, 450 hp at 600 V normal duty, 394 kVA, STO SIL 3, integrated EMC filter C3, cabinet mount.","salesMarkdown":"The ATV9A0C40T6 is a modular Altivar Process ATV900 drive from Schneider Electric, rated 450 hp at 600 V normal duty (379 A line current) and 350 hp at heavy duty (298 A), with Safe Torque Off SIL 3 as a built-in safety function. It runs both synchronous and asynchronous motors, and the integrated EMC filter meets Category C3 for 300 m cable runs, reducing external filtering needs in industrial installations. Power is supplied at 50/60 Hz, and the drive includes a full set of protective functions: motor thermal, drive thermal, STO, overcurrent, overvoltage, undervoltage, phase loss, and overspeed. ## Specifications at a glance Normal duty delivers 394 kVA apparent power at 600 V; heavy duty delivers 310 kVA. Prospective line short-circuit current rating is 50 kA. Switching frequency is adjustable from 2 to 4.9 kHz with derating; forced convection cooling handles the thermal load inside an IP00 chassis intended for IP21 or IP54 cabinet integration. The drive accepts line-side screw terminals and motor-side M10 bars. Control connections use removable screw terminals, 0.5–1.5 mm². Ambient conditions: pollution degree 2 per IEC 61800-5-1, operating altitude up to 2000 m with derating above 1000 m, shock 4 gn for 11 ms, vibration 1.5 mm at 2–13 Hz and 0.5 gn at 13–200 Hz. ## Fieldbus and I/O flexibility The modular design provides three option slots (A, B, C). Slot A accepts Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen (RJ45, SUB-D 9, or screw terminals). Slots B and C support digital and analog I/O extension modules and a relay output module. Built-in communication includes Modbus serial (RS-485 2-wire, 4.8–38.4 kbps, RTU, 1–247 addresses) and Ethernet IP/Modbus TCP (10/100 Mbps, half/full duplex, auto-negotiation). Digital inputs can be supplied externally at 24 V DC (19–30 V); internal supply for reference potentiometer (1–10 kΩ) is 10.5 V DC ±5%; internal supply for digital inputs and STO is 24 V DC (21–27 V). Insulation resistance is 1 MΩ at 500 V DC for 1 min. Encoder feedback options include a 5/12 V digital encoder interface, analog encoder interface, and resolver interface — all via Slot B. As part of the Altivar Process ATV900 family, it shares common accessories, software, and documentation with other drives in the series — good for spares continuity and design-in confidence. For firm lead times and pricing specific to your order quantity, submit an RFQ through this listing. The modular slot architecture means option cards (Profibus, PROFINET, EtherCAT, etc.) must be ordered separately for fieldbus integration. The drive complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental), IEC 61508 & ISO 13849-1 (functional safety), and UL 61800-5-1. Markings include CE; the STO function is rated SIL 3. UL type 1 and type 12 are conformant for cabinet integration. Total harmonic current distortion (THDI) is less than 48% from 80–100% load. Noise level is 70 dB per 86/188/EEC.","metaTitle":"ATV9A0C40T6 Altivar Process Drive 450 hp STO SIL3","metaDescription":"Active production ATV9A0C40T6 modular drive rated 450 hp at 600 V normal duty, 394 kVA, STO SIL 3, integrated EMC filter C3. Supports synchronous/asynchronous motors, multiple fiel","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV9A0C40T6","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"70 dB 86/188/EEC","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module","description":"Variable speed drive, Altivar Process ATV900, APM, single 600 V, 450 hp","Line current":"379.0 A 600 V normal duty) 298.0 A 600 V heavy duty)","Maximum THDI":"<48 % from 80...100 % of load","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"394.0 kVA at 600 V normal duty 310.0 kVA at 600 V heavy duty","Motor power hp":"450.0 hp at 600 V normal duty 350.0 hp at 600 V heavy duty","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 2.0 power module 200 kW 1 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"425.0 A at 2.5 kHz normal duty 340.0 A at 2.5 kHz heavy duty","Maximum transient current":"510.0 A 60 s normal duty) 510.0 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"600 V - 10...15 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ca/en/product/ATV9A0C40T6/variable-speed-drive-altivar-process-atv900-apm-single-600-v-450-hp/"},"ai":{"faq":[{"question":"What is the supply configuration for digital inputs and STO?","answer":"Digital inputs accept an external 24 V DC supply (19–30 V). There is also an internal 24 V DC supply for digital inputs and STO operating at 21–27 V, and a 10.5 V DC ±5% supply for a reference potentiometer (1–10 kΩ)."},{"question":"What markings and certifications does ATV9A0C40T6 carry?","answer":"It carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, ISO 13849-1, and UL 61800-5-1. STO is rated SIL 3."},{"question":"What compliance documentation is available for this drive?","answer":"The drive is designed to meet the listed IEC and UL standards. Typical documentation includes a CE declaration of conformity, UL listing information, and functional safety manual for STO. For specific compliance certificates, consult the product documentation or submit an RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C40T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C40T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}