{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C45T4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C45T4","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C45T4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C45T4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, modular variable speed drive, ATV9A0C45T4, 650 hp at 480 V normal duty, 550 hp heavy duty, 569 kVA, STO SIL 3, IP00.","salesMarkdown":"The Schneider ATV9A0C45T4 is a modular Altivar Process ATV900 drive sized for 650 hp at 480 V normal duty or 550 hp heavy duty, pulling 685 A or 586 A line current respectively. Apparent power comes to 569 kVA at normal duty, 487 kVA heavy duty. It handles synchronous and asynchronous motors, with a switching frequency adjustable from 2 to 8 kHz — derate above 2.5 kHz. The integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs. ## Supply and control architecture Digital inputs need an external 24 V DC supply (19...30 V). The drive also provides an internal 10.5 V DC supply for a 1 to 10 kOhm reference potentiometer, plus a separate 24 V DC (21...27 V) supply for digital inputs and STO. Control wiring lands on removable screw terminals accepting 0.5...1.5 mm² (AWG 20...16). Line-side connection uses screw terminals; motor connection uses M10 x 2 bars. ## Safety and standards STO (safe torque off) is rated SIL 3. The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Pollution degree 2 per IEC 61800-5-1. Prospective line Isc is 50 kA. IP00 rating — intended for IP21 or IP54 cabinet integration. Operating altitude up to 4800 m with current derating above 1000 m. ## Fieldbus and option slots Slot A accepts Profibus DP V1, PROFINET, DeviceNet, EtherCAT, or CANopen (daisy chain RJ45, SUB-D 9, or screw terminals). Slots A/B/C accept digital/analog I/O extension or output relay modules. Slot B also accepts 5/12 V digital encoder or analog encoder or resolver modules. Built-in Ethernet IP/Modbus TCP on 2 RJ45 ports (10/100 Mbit/s, half/full duplex, autonegotiation). Modbus serial on 1 RJ45, 2-wire RS-485, RTU frame, 4.8 to 38.4 kbit/s, addresses 1...247.","metaTitle":"Schneider ATV9A0C45T4 Altivar Process ATV900, 650 hp at 480","metaDescription":"Schneider ATV9A0C45T4 Altivar Process ATV900 drive. 650 hp normal duty / 550 hp heavy duty at 480 V. STO SIL 3. Active lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"685.0 A at 480 V (normal duty) 586.0 A at 480 V (heavy duty)","Frequency":"50...60 Hz +/- 5 %","Horsepower":"650.0 hp at 480 V normal duty 550.0 hp at 480 V heavy duty","Data Format":"8 bits, configurable odd, even or no parity for Modbus serial","Connector Type":"2 RJ45 for Ethernet IP/Modbus TCP on the control block 1 RJ45 for Modbus serial on the control block","Product Status":"Active","Pollution Degree":"2 conforming to IEC 61800-5-1","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.2 °C","Temperature Storage":"-40...70 °C","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV9A0C45T4/variable-speed-drive-altivar-process-atv900-apm-single-480-v-650-hp/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C45T4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C45T4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C45T4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}