{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C50T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C50T6","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C50T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C50T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, Modular version, 550 hp at 600 V normal duty, integrated EMC filter category C3, Safe Torque Off SIL 3, dual protocol Ethernet and serial Modbus.","salesMarkdown":"The ATV9A0C50T6: Cabinet-mount Altivar Process ATV900 rated 550 hp at 600 V normal duty (464 A line current) and 450 hp heavy duty (383 A). Switching frequency adjustable 2–4.9 kHz with derating; suits standard induction and synchronous motors. Integrated EMC filter rated for 984.3 ft (300 m) cable at IEC 61800-3 category C3 level – no external filter needed for most industrial environments. Safe Torque Off SIL 3 included on the control board; break on the control circuit drive protection covers the loop. Current production – no end-of-life notice. Standard lead times apply; RFQ for firm pricing and availability. CE marked, complies with IEC 61800-5-1, UL 61800-5-1, IEC 61508, and IEC 13849-1 for functional safety. Pollution degree 2 per IEC 61800-5-1. Documentation pack includes declaration of conformity for CE/UKCA; RoHS/REACH declarations available on request. ## Control and supply wiring Digital inputs powered from an external 24 V DC supply (19–30 V); a separate 24 V feed (21–27 V) runs the STO logic. Internal 10.5 V DC ±5% reference for a 1–10 kΩ potentiometer. Control terminals are removable screw, 0.5–1.5 mm² (AWG 20–16). Motor connection via M10 bars. Forced convection cooling; cabinet must provide IP21 or IP54 via the enclosure. UL type 1/12 when integrated. ## Fieldbus and options Comes standard with dual Ethernet (Modbus TCP / EtherNet/IP) at 10/100 Mbit/s and a two-wire RS-485 Modbus serial link (RTU frame, 1–247 addresses). Slot A accepts Profibus DP V1, PROFINET, DeviceNet, EtherCAT, or CANopen (RJ45, SUB-D 9, or screw terminals). Slots B and C accept I/O or relay extensions. Line current at 600 V: 464 A normal duty, 383 A heavy duty. Prospective short-circuit current 50 kA.","metaTitle":"Schneider ATV9A0C50T6 ATV900 Drive, 550 hp, 600 V","metaDescription":"Schneider Altivar Process ATV9A0C50T6 VFD, 550 hp (600 V normal duty), integrated EMC C3, STO SIL 3. Active production. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV9A0C50T6","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"71 dB 86/188/EEC","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module","description":"Variable speed drive, Altivar Process ATV900, APM, single 600 V, 550 hp","Line current":"464.0 A 600 V normal duty) 383.0 A 600 V heavy duty)","Maximum THDI":"<48 % from 80...100 % of load","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"482.0 kVA at 600 V normal duty 398.0 kVA at 600 V heavy duty","Motor power hp":"550.0 hp at 600 V normal duty 450.0 hp at 600 V heavy duty","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 3.0 power module 200 kW 2 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"520.0 A at 2.5 kHz normal duty 425.0 A at 2.5 kHz heavy duty","Maximum transient current":"624.0 A 60 s normal duty) 637.5 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"600 V - 10...15 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ca/en/product/ATV9A0C50T6/variable-speed-drive-altivar-process-atv900-apm-single-600-v-550-hp/"},"ai":{"faq":[{"question":"What are the supply voltage requirements for the control circuits?","answer":"Digital inputs need an external 24 V DC (19–30 V). STO logic requires a separate 24 V DC (21–27 V). A 10.5 V DC ±5% reference is provided for a 1–10 kΩ potentiometer."},{"question":"What compliance markings and standards does this drive carry?","answer":"It carries CE marking and complies with IEC 61800-5-1, UL 61800-5-1, IEC 61508, IEC 13849-1, and pollution degree 2. Safety function STO SIL 3 is built in."},{"question":"What motor types can the ATV9A0C50T6 control?","answer":"It is rated for both synchronous and asynchronous motors, covering induction and permanent magnet machines."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C50T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C50T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}