{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C56Q4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C56Q4","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C56Q4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C56Q4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 modular AC drive, ATV9A0C56Q4, 560 kW normal duty / 450 kW heavy duty at 400 V, 948 A line current, STO SIL 3, IP00 cabinet mount.","salesMarkdown":"## 560 kW at 400 V — the heavy-lift VFD for process lines The ATV9A0C56Q4 is a Schneider Electric Altivar Process ATV900 modular AC drive rated 560 kW at 400 V in normal duty and 450 kW at 400 V in heavy duty — the heavy-duty figure governs continuous motor overload margin on conveyors, pumps, and compressors that see sustained load. Line current at 400 V is 948 A normal duty / 767 A heavy duty, with a prospective line Isc of 50 kA — the input fusing and cable sizing need to handle that fault level upstream. ## Safety and standards — STO SIL 3, multi-standard compliance Safe torque off (STO) is integrated at SIL 3 per IEC 61508 and IEC 13849-1 — the drive can be wired into a safety circuit that removes torque without a separate safety relay, saving panel space on guarding applications. The integrated EMC filter meets IEC 61800-3 category C3 with 300 m of motor cable — suitable for industrial environments where conducted emissions are managed within a controlled installation. CE marked; pollution degree 2 per IEC 61800-5-1; vibration resistance per IEC 60068-2-6 (1.5 mm peak-to-peak at 2-13 Hz, 0.5 gn at 13-200 Hz).","metaTitle":"Schneider ATV9A0C56Q4 Altivar Process ATV900 VFD, 560 kW","metaDescription":"Schneider Electric ATV9A0C56Q4 Altivar Process ATV900 AC drive, 560 kW normal duty at 400 V, 948 A line current, STO SIL 3, integrated EMC filter C3.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV9A0C56Q4","Supply":"External supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), 1 MOhm at 500 V DC, 1 min, earth","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated with 300 m conforming to IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity for Modbus serial","Noise level":"73 dB conforming to 86/188/EEC","Option card":"Slot A: communication module for Profibus DP V1 Slot A: communication module for PROFINET Slot A: communication module for DeviceNet Slot A: communication module for EtherCAT Slot A: communication module for CANopen daisy chain RJ45 Slot A: communication module for CANopen SUB-D 9 Slot A: communication module for CANopen screw terminals Slot A/slot B/slot C: digital and analog I/O extension module Slot A/slot B/slot C: output relay extension module Slot B: 5/12 V digital encoder interface module Slot B: analog encoder interface module Slot B: resolver encoder interface module","description":"Variable speed drive, Altivar Process ATV900, APM, single 400 V, 560 kW","Line current":"948.0 A at 400 V (normal duty) 767.0 A at 400 V (heavy duty)","Maximum THDI":"<48 % from 80...100 % of load","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"657.0 kVA at 400 V normal duty 531.0 kVA at 400 V heavy duty","Connector type":"2 RJ45 for Ethernet IP/Modbus TCP on the control block 1 RJ45 for Modbus serial on the control block","Motor power kW":"560.0 kW at 400 V normal duty 450.0 kW at 400 V heavy duty","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 4.0 power module 160 kW 3 front cover","Protection type":"Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 conforming to IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"7 gn for 11 ms conforming to IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9A0","Relative humidity":"5...95 % without condensation conforming to IEC 60068-2-3","Transmission rate":"10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial","Operating altitude":"0...4800 m with current derating above 1000m","Physical interface":"2-wire RS 485 for Modbus serial","Transmission frame":"RTU for Modbus serial","Number of addresses":"1...247 for Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Frequency resolution":"Display unit: 0.1 Hz Analog input: 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance for Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16 Line side: screw terminal Motor: M10 x 2 bars","IP degree of protection":"IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"1020.0 A at 2.5 kHz normal duty 830.0 A at 2.5 kHz heavy duty","Maximum transient current":"1224.0 A during 60 s (normal duty) 1245.0 A during 60 s (heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"400 V - 15...10 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...70 °C","Permissible temporary current boost":"1.2 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty)","Ambient air temperature for operation":"-10...40 °C without derating 40...50 °C with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV9A0C56Q4?filename=Schneider+Electric_Altivar-Process-ATV900_ATV9A0C56Q4.pdf', 'path_name': 'e046d9d81f449deb8283c641176a663a.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/e046d9d81f449deb8283c641176a663a.pdf', 'status': 1}","sourceUrl":"https://www.se.com/th/en/product/ATV9A0C56Q4/variable-speed-drive-altivar-process-atv900-apm-single-400-v-560-kw/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for ATV9A0C56Q4?","answer":"The drive carries CE marking and complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental), IEC 61508 (functional safety), and IEC 13849-1 (safety-related parts)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C56Q4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C56Q4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}