{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C63Q4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C63Q4","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C63Q4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C63Q4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, ATV9A0C63Q4, modular AC drive, 630 kW at 400 V normal duty, 500 kW heavy duty, 1058 A line current, STO SIL 3, CE marked.","salesMarkdown":"## Drive rating and duty selection The ATV9A0C63Q4 is a modular Altivar Process ATV900 AC drive rated 630 kW at 400 V in normal duty and 500 kW at 400 V in heavy duty, with corresponding line currents of 1058 A and 849 A respectively. Heavy-duty rating governs continuous overload capability for high-torque loads such as conveyors or extruders; normal duty applies to variable-torque loads like centrifugal pumps and fans where peak demand is lower. ## Safety and control supply architecture Control supply is internally generated: 24 V DC for digital inputs and STO (21...27 V), plus a 10.5 V DC reference for an external 1 to 10 kOhm potentiometer. The digital input supply can also be fed externally at 19...30 V DC if isolation from the drive's internal rail is required. ## Fieldbus and option slot flexibility Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, EtherCAT, or CANopen (RJ45, SUB-D 9, or screw terminals). Slots A, B, and C also accept digital/analog I/O extension and output relay modules. Slot B supports encoder interface modules (5/12 V digital, analog, or resolver), making the drive suitable for closed-loop speed or position control on synchronous or asynchronous motors. Built-in dual RJ45 ports for Ethernet IP/Modbus TCP at 10/100 Mbit/s, plus a separate RJ45 for Modbus serial (RTU, 4.8 to 38.4 kbit/s) — the drive ships as a Modbus TCP slave with autonegotiation. ## Switching frequency and derating Adjustable switching frequency from 2 to 8 kHz (factory default 2.5 kHz). Raising the carrier above 2.5 kHz reduces audible motor noise but derates the continuous output current — the derating factor is applied above the base frequency and must be accounted for in the thermal budget at full load.","metaTitle":"Schneider Electric ATV9A0C63Q4 Altivar Process ATV900","metaDescription":"Schneider Electric ATV9A0C63Q4 Altivar Process ATV900 AC drive, 630 kW at 400 V normal duty, STO SIL 3, CE marked. Quoted to order against your BOM.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"1058.0 A at 400 V (normal duty) 849.0 A at 400 V (heavy duty)","Frequency":"50...60 Hz +/- 5 %","Data Format":"8 bits, configurable odd, even or no parity for Modbus serial","Connector Type":"2 RJ45 for Ethernet IP/Modbus TCP on the control block 1 RJ45 for Modbus serial on the control block","Product Status":"Active","Pollution Degree":"2 conforming to IEC 61800-5-1","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.2 °C","Temperature Storage":"-40...70 °C","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV9A0C63Q4/variable-speed-drive-altivar-process-atv900-apm-single-400-v-630-kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C63Q4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C63Q4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C63Q4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}