{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9A0C80Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9A0C80Q6","canonicalUrl":"https://aoctrl.com/schneider/ATV9A0C80Q6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9A0C80Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 modular drive, ATV9A0C80Q6, 800 kW at 690 V normal duty, 630 kW heavy duty, integrated EMC filter C3, STO SIL 3.","salesMarkdown":"The Schneider ATV9A0C80Q6 is a modular Altivar Process ATV900 drive rated for 800 kW at 690 V normal duty and 630 kW at 690 V heavy duty. That places it on the high end of the ATV900 frame — meant for large induction or synchronous motors in pump, fan, compressor, or conveyor applications where you need the full 690 V line. It ships as a kit: control unit, mechanical mounting kit, power connection set, fuses, a 200 kW power module, and one front cover. Modular construction means you can swap power modules without pulling the whole cabinet, which is a relief if you're stocking spares for multiple frame sizes. Motor power is your first check: 800 kW normal duty (typically for variable torque loads like pumps and fans) and 630 kW heavy duty (constant torque like conveyors or extruders). The switching frequency is adjustable from 2 to 4.9 kHz — lower settings reduce losses and allow higher current; higher settings quiet the motor but require derating. Plan for the derating curve if you push past 4 kHz. The integrated EMC filter meets IEC 61800-3 category C3 with 300 m cable length. In a North American panel, this usually satisfies the conducted emissions requirement without an add-on filter — saves a DIN rail slot and a wiring step. Pollution degree 2 is standard for a protected cabinet environment. Safe torque off (STO) is built in at SIL 3. That means you can wire the safety circuit directly to the drive without a separate safety relay for the torque-off function — reduces component count and wiring when you're doing a PL e or SIL 3 safety system. Communication flexibility: Slot A accepts Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen (two variants), and more. Slot B and C handle I/O and encoder extension. The base unit includes one Modbus serial port (2-wire RS-485, RTU) and one Ethernet port for Modbus TCP — so you can talk to the PLC immediately while the fieldbus card is on order.","metaTitle":"Schneider ATV9A0C80Q6 Altivar Process Drive, 800 kW","metaDescription":"Modular Altivar Process ATV900 drive, 800 kW at 690V normal duty, 630 kW heavy duty. Integrated EMC filter C3, STO SIL 3, multi-protocol. Current production, sourced to order. RFQ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV9A0C80Q6","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"73 dB 86/188/EEC","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module EtherCAT Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module","description":"Variable speed drive, Altivar Process ATV900, APM, single 690 V, 800 kW","Line current":"776.0 A 690 V normal duty) 619.0 A 690 V heavy duty)","Maximum THDI":"<48 % from 80...100 % of load","Exchange mode":"Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP","Mounting mode":"Cabinet mount","Apparent power":"927.0 kVA at 690 V normal duty 740.0 kVA at 690 V heavy duty","Motor power kW":"800.0 kW at 690 V normal duty 630.0 kW at 690 V heavy duty","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 4.0 power module 200 kW 3 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9A0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"830.0 A at 2.5 kHz normal duty 650.0 A at 2.5 kHz heavy duty","Maximum transient current":"996.0 A 60 s normal duty) 975.0 A 60 s heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"690 V - 10...15 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/za/en/product/ATV9A0C80Q6/variable-speed-drive-altivar-process-atv900-apm-single-690-v-800-kw/"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"It delivers 800 kW at 690 V in normal duty (variable torque) and 630 kW in heavy duty (constant torque). The integrated EMC filter is category C3 for 300 m cable. STO is built in at SIL 3. Communication options include Modbus serial, Ethernet Modbus TCP, and a slot for Profibus, PROFINET, EtherCAT, DeviceNet, or CANopen."},{"question":"What compliance documentation is available for ATV9A0C80Q6?","answer":"The drive is CE marked and complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental), IEC 61508, and ISO 13849-1 for functional safety. Integrated EMC filter meets IEC 61800-3 category C3."},{"question":"What is the listed supply for this drive?","answer":"The control section requires an external 24 V DC supply for digital inputs (19...30 V), and provides an internal 10.5 V DC supply for a reference potentiometer (1 to 10 kOhm). The internal supply for digital inputs and STO is 24 V DC (21...27 V). Insulation resistance is 1 MOhm at 500 V DC for 1 minute."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9A0C80Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9A0C80Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}