{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9B0C11N6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9B0C11N6","canonicalUrl":"https://aoctrl.com/schneider/ATV9B0C11N6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9B0C11N6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, modular drive, ATV9B0C11N6, 75 kW at 500 V normal duty, 55 kW heavy duty, integrated EMC filter C3, STO SIL 3.","salesMarkdown":"The Schneider ATV9B0C11N6 is an Altivar Process ATV900 modular drive rated for 75 kW at 500 V normal duty and 55 kW at 500 V heavy duty. It draws 98 A line current in normal duty and 72 A in heavy duty at 500 V. The drive supports both synchronous and asynchronous motors and includes an integrated EMC filter compliant with IEC 61800-3 category C3 for installations up to 300 m cable length. ## Control supply and safety Control power comes from an external 24 V DC supply (19...30 V) for digital inputs, plus an internal 24 V DC (21...27 V) supply for digital inputs and STO. A separate 10.5 V DC reference supply is available for a 1 to 10 kOhm potentiometer. ## Communication and expansion The drive comes with dual RJ45 Ethernet IP/Modbus TCP ports and one RJ45 Modbus serial port (2-wire RS-485, RTU, 4.8 to 38.4 kbit/s). Slot A accepts fieldbus option cards for Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT. Slots A, B, and C accept digital/analog I/O extension modules and output relay modules. Slot B also accepts encoder interface modules (5/12 V digital, analog, or resolver). ## Ratings and environment Switching frequency is adjustable from 2 to 4.9 kHz with derating. Apparent power is 85 kVA at 500 V normal duty and 62 kVA at 500 V heavy duty. The drive is cabinet mount with IP00 protection (IP21 or IP54 in cabinet), pollution degree 2, and operates at 50/60 Hz ±5 %. It is rated for altitudes up to 2000 m with derating above 1000 m, and vibration resistance per IEC 60068-2-6.","metaTitle":"Schneider ATV9B0C11N6 Altivar Process ATV900 Drive, 75 kW","metaDescription":"Schneider ATV9B0C11N6 Altivar Process ATV900 drive, 75 kW at 500 V normal duty, 55 kW heavy duty. Active production, sourced to order. Integrated EMC filter C3, STO SIL 3, modular","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drives (VFD)"],"specifications":{"title":"ATV9B0C11N6","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"70 dB 86/188/EEC","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A communication module EtherCAT Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module","description":"Variable speed drive, Altivar Process ATV900, APM, Low Harmonic/Regen 500 V, 75 kW","Line current":"98.0 A 500 V normal duty) 72.0 A 500 V heavy duty) 76.0 A 500 V regenerative mode normal duty) 56.0 A 500 V regenerative mode heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Mounting mode":"Cabinet mount","Apparent power":"85.0 kVA at 500 V normal duty 62.0 kVA at 500 V heavy duty 66.0 kVA at 500 V normal duty regenerative mode 48.0 kVA at 500 V heavy duty regenerative mode","Connector type":"2 RJ45 Ethernet IP/Modbus TCP on terminal 1 RJ45 Modbus serial on terminal","Motor power kW":"75.0 kW at 500 V normal duty 55.0 kW at 500 V heavy duty 75.0 kW at 500 V normal duty regenerative mode 55.0 kW at 500 V heavy duty regenerative mode","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"125.0 A at 2.5 kHz normal duty 105.0 A at 2.5 kHz heavy duty 125.0 A at 2.5 kHz normal duty regenerative mode 105.0 A at 2.5 kHz heavy duty regenerative mode","Maximum transient current":"150.0 A 60 s normal duty) 157.5 A 60 s heavy duty) 150.0 A 60 s regenerative mode normal duty) 157.5 A 60 s regenerative mode heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"500 V - 10...15 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/ATV9B0C11N6/variable-speed-drive-altivar-process-atv900-apm-low-harmonic-regen-500-v-75-kw/"},"ai":{"faq":[{"question":"What are the key ratings for the ATV9B0C11N6?","answer":"It is rated 75 kW at 500 V normal duty and 55 kW at 500 V heavy duty, with line currents of 98 A and 72 A respectively. Apparent power is 85 kVA normal duty and 62 kVA heavy duty. Switching frequency is adjustable 2 to 4.9 kHz."},{"question":"What safety functions does the ATV9B0C11N6 include?","answer":"It includes Safe Torque Off (STO) rated SIL 3 per IEC 61508 and IEC 13849-1."},{"question":"What communication protocols does the ATV9B0C11N6 support?","answer":"It has dual Ethernet IP/Modbus TCP ports and one Modbus serial port (RS-485, RTU). Option cards for Slot A add Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9B0C11N6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9B0C11N6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}