{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9B0C13Q4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9B0C13Q4","canonicalUrl":"https://aoctrl.com/schneider/ATV9B0C13Q4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9B0C13Q4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, ATV9B0C13Q4, 132 kW at 400 V normal duty, 208 A line current, modular cabinet mount.","salesMarkdown":"The ATV9B0C13Q4: The drive carries separate normal-duty and heavy-duty curves. Normal duty delivers 132 kW / 208 A / 144 kVA; heavy duty delivers 110 kW / 174 A / 121 kVA. Regenerative-mode ratings are also specified: 132 kW / 173.8 A / 120.4 kVA normal duty, 110 kW / 144.1 A / 99.8 kVA heavy duty. The switching frequency is adjustable 2 to 8 kHz with derating above 2.5 kHz. ## Safety and compliance Safe Torque Off (STO) rated SIL 3 is integrated. The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The integrated EMC filter meets category C3 per IEC 61800-3 for cable runs up to 300 m. Pollution degree 2 per IEC 61800-5-1. ## Supply and control Digital inputs require an external 24 V DC supply (19...30 V). An internal 10.5 V DC supply powers a reference potentiometer (1 to 10 kOhm). The STO and digital input internal supply is 24 V DC (21...27 V). Insulation resistance is 1 MOhm at 500 V DC for 1 minute to earth. ## Fieldbus and option slots The drive includes 2 RJ45 ports for Ethernet IP/Modbus TCP and 1 RJ45 for Modbus serial (RS-485, 2-wire, RTU frame, 4.8 to 38.4 kbit/s). Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT communication modules. Slot B accepts digital/analog I/O extension, output relay, or encoder interface modules (digital 5/12 V, analog, or resolver). Slot C also accepts I/O or relay extensions.","metaTitle":"Schneider ATV9B0C13Q4 Altivar Process ATV900, 132 kW, 208 A","metaDescription":"Schneider ATV9B0C13Q4 Altivar Process ATV900 drive, 132 kW at 400 V normal duty, 208 A line current, STO SIL 3, integrated EMC filter. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"208.0 A at 400 V (normal duty) 174.0 A at 400 V (heavy duty) 173.8 A at 400 V regenerative mode (normal duty) 144.1 A at 400 V regenerative mode (heavy duty)","Frequency":"50...60 Hz +/- 5 %","Data Format":"8 bits, configurable odd, even or no parity for Modbus serial","Connector Type":"2 RJ45 for Ethernet IP/Modbus TCP on terminal 1 RJ45 for Modbus serial on terminal","Product Status":"Active","Pollution Degree":"2 conforming to IEC 61800-5-1","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.2 °C","Temperature Storage":"-40...70 °C","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV9B0C13Q4/variable-speed-drive-apm-atv900-low-harmonic-regen-drive-400-v-132-kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV9B0C13Q4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9B0C13Q4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9B0C13Q4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}