{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9B0C13Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9B0C13Q6","canonicalUrl":"https://aoctrl.com/schneider/ATV9B0C13Q6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9B0C13Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, modular VFD, ATV9B0C13Q6, 132 kW at 690 V normal duty, STO SIL 3, integrated C3 EMC filter.","salesMarkdown":"The Schneider Electric ATV9B0C13Q6 is a modular Altivar Process ATV900 variable frequency drive sized for 132 kW at 690 V normal duty (110 kW heavy duty), with a line current of 122 A normal duty and 102 A heavy duty at 690 V. It drives both synchronous and asynchronous motors, and its integrated EMC filter meets IEC 61800-3 category C3 for conducted emissions up to 300 m of motor cable. The 132 kW normal-duty rating at 690 V is the headline motor power for continuous variable-torque loads like pumps and fans. The heavy-duty 110 kW rating applies for constant-torque or high-starting-torque applications such as conveyors or extruders, where the drive must deliver rated current for longer acceleration periods. The corresponding line currents — 122 A normal duty, 102 A heavy duty — govern input-side conductor and fuse sizing. This is a hard requirement for any safety-related drive application — it removes the need for an external safety contactor in many machine-safety architectures. The integrated EMC filter is category C3, which is standard for industrial environments with a dedicated transformer or separate supply. It limits conducted emissions so the drive can be installed without an external filter in most industrial panels, but note that C3 is not suitable for residential or public low-voltage networks without additional attenuation. ## Control supply and fieldbus architecture The control section needs an external 24 V DC supply (19...30 V) for the digital inputs, plus a separate internal 24 V DC supply (21...27 V) for the digital inputs and STO logic. There is also a 10.5 V DC ±5 % reference output for a 1 to 10 kΩ potentiometer. This means the drive requires a clean 24 V control supply — do not share it with solenoid or contactor coils without isolation. Communication is handled via two RJ45 ports for Ethernet IP / Modbus TCP (10/100 Mbit/s) and one RJ45 for Modbus serial (RTU, 4.8 to 38.4 kbit/s). The Modbus serial uses 2-wire RS-485 with no impedance polarization, so you will need external bias resistors if the bus has more than a few nodes. Slot A accepts option cards for Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT — choose the card that matches your PLC network.","metaTitle":"Schneider ATV9B0C13Q6 Altivar Process ATV900, 132 kW at 690","metaDescription":"Active-production ATV9B0C13Q6 from Schneider Altivar Process ATV900 series. 132 kW at 690 V normal duty, STO SIL 3, integrated C3 EMC filter. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV9B0C13Q6","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"70 dB 86/188/EEC","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A communication module EtherCAT Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module","description":"Variable speed drive, Altivar Process ATV900, APM, Low Harmonic/Regen 690 V, 132 kW","Line current":"122.0 A 690 V normal duty) 102.0 A 690 V heavy duty) 99.0 A 690 V regenerative mode normal duty) 82.0 A 690 V regenerative mode heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Mounting mode":"Cabinet mount","Apparent power":"146.0 kVA at 690 V normal duty 122.0 kVA at 690 V heavy duty 119.0 kVA at 690 V normal duty regenerative mode 98.0 kVA at 690 V heavy duty regenerative mode","Connector type":"2 RJ45 Ethernet IP/Modbus TCP on terminal 1 RJ45 Modbus serial on terminal","Motor power kW":"132.0 kW at 690 V normal duty 110.0 kW at 690 V heavy duty 132.0 kW at 690 V normal duty regenerative mode 110.0 kW at 690 V heavy duty regenerative mode","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 1.0 power module 200 kW","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"145.0 A at 2.5 kHz normal duty 125.0 A at 2.5 kHz heavy duty 145.0 A at 2.5 kHz normal duty regenerative mode 125.0 A at 2.5 kHz heavy duty regenerative mode","Maximum transient current":"174.0 A 60 s normal duty) 187.5 A 60 s heavy duty) 174.0 A 60 s regenerative mode normal duty) 187.5 A 60 s regenerative mode heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"690 V - 10...15 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/th/en/product/ATV9B0C13Q6/variable-speed-drive-altivar-process-atv900-apm-low-harmonic-regen-690-v-132-kw/"},"ai":{"faq":[{"question":"What are the motor power ratings for this drive?","answer":"At 690 V, it delivers 132 kW normal duty and 110 kW heavy duty. In regenerative mode, the ratings are 132 kW normal duty and 110 kW heavy duty."},{"question":"What safety function does the ATV9B0C13Q6 support?","answer":"It supports Safe Torque Off (STO) rated SIL 3 per IEC 61508 and IEC 13849-1."},{"question":"What fieldbus options are available for this drive?","answer":"The drive has two RJ45 ports for Ethernet IP / Modbus TCP and one RJ45 for Modbus serial (RTU). Slot A accepts option cards for Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT."},{"question":"What is the integrated EMC filter category?","answer":"The integrated EMC filter meets IEC 61800-3 category C3, suitable for industrial environments with a dedicated supply."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9B0C13Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9B0C13Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}