{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9B0C25T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9B0C25T6","canonicalUrl":"https://aoctrl.com/schneider/ATV9B0C25T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9B0C25T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, modular VFD, ATV9B0C25T6, 250 hp at 600 V normal duty, 200 hp heavy duty, STO SIL 3.","salesMarkdown":"## Drive ratings and duty selection The ATV9B0C25T6 is a modular Altivar Process ATV900 drive sized for 250 hp at 600 V normal duty and 200 hp at 600 V heavy duty. Line current at 600 V runs 199 A normal duty, 160 A heavy duty, with regenerative-mode ratings of 162 A and 129 A respectively. Apparent power follows: 207 kVA normal, 166 kVA heavy. ## Control supply and safety Digital inputs and STO take a 24 V DC supply (21...27 V). There is a separate 10.5 V DC reference output for a 1 to 10 kOhm potentiometer, and the external digital input supply is 24 V DC (19...30 V). The STO function is rated SIL 3 — that is a certified safe torque off, not just a software inhibit. If you are wiring a safety relay or PLC safety output, the 24 V DC STO supply must be kept separate from the control logic supply to maintain isolation. ## Fieldbus and I/O options Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT. Slots A, B, and C also take digital/analog I/O extension modules and output relay extension modules. Slot B handles encoder interfaces (5/12 V digital, analog, or resolver). The drive ships with dual RJ45 Ethernet IP/Modbus TCP ports and one RJ45 Modbus serial port; Modbus serial runs RTU at 4.8 to 38.4 kbit/s, 8-bit configurable parity. For a new line, pick the fieldbus card early — the slot assignment determines which options coexist. ## EMC and environment Integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs. The drive is cabinet-mount only, rated IP00 for integration into IP21 or IP54 enclosures. Operating altitude is 0 to 2000 m with derating above 1000 m; ambient humidity 5 to 95% non-condensing. Switching frequency is adjustable 2 to 4.9 kHz with derating — lower switching frequency reduces heat and extends cable length, higher reduces motor noise.","metaTitle":"Schneider ATV9B0C25T6 Altivar Process ATV900 Drive, 250 HP a","metaDescription":"Schneider Altivar Process ATV900 drive ATV9B0C25T6, 250 hp at 600 V normal duty, 200 hp heavy duty. STO SIL 3, integrated EMC filter C3. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"title":"ATV9B0C25T6","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"73 dB 86/188/EEC","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A communication module EtherCAT Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module","description":"Variable speed drive, Altivar Process ATV900, APM, Low Harmonic/Regen 600 V, 250 hp","Line current":"199.0 A 600 V normal duty) 160.0 A 600 V heavy duty) 162.0 A 600 V regenerative mode normal duty) 129.0 A 600 V regenerative mode heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Mounting mode":"Cabinet mount","Apparent power":"207.0 kVA at 600 V normal duty 166.0 kVA at 600 V heavy duty 169.0 kVA at 600 V normal duty regenerative mode 134.0 kVA at 600 V heavy duty regenerative mode","Connector type":"2 RJ45 Ethernet IP/Modbus TCP on terminal 1 RJ45 Modbus serial on terminal","Motor power hp":"250.0 hp at 600 V normal duty 200.0 hp at 600 V heavy duty 250.0 hp at 600 V normal duty regenerative mode 200.0 hp at 600 V heavy duty regenerative mode","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 2.0 power module 200 kW 1 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...2000 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2...4.9 kHz adjustable with derating factor","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Prospective line Isc":"50 kA","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"275.0 A at 2.5 kHz normal duty 215.0 A at 2.5 kHz heavy duty 275.0 A at 2.5 kHz normal duty regenerative mode 215.0 A at 2.5 kHz heavy duty regenerative mode","Maximum transient current":"330.0 A 60 s normal duty) 322.5 A 60 s heavy duty) 330.0 A 60 s regenerative mode normal duty) 322.5 A 60 s regenerative mode heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"600 V - 10...15 %","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ca/en/product/ATV9B0C25T6/variable-speed-drive-altivar-process-atv900-apm-low-harmonic-regen-600-v-250-hp/"},"ai":{"faq":[{"question":"What are the key ratings for the ATV9B0C25T6?","answer":"It is rated 250 hp at 600 V normal duty, 200 hp at 600 V heavy duty, with line currents of 199 A and 160 A respectively. Apparent power is 207 kVA normal duty, 166 kVA heavy duty."},{"question":"What safety functions does the ATV9B0C25T6 support?","answer":"It includes STO (safe torque off) rated SIL 3."},{"question":"What fieldbus options are available for the ATV9B0C25T6?","answer":"Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT communication modules."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9B0C25T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9B0C25T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}