{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9B0C40T4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9B0C40T4","canonicalUrl":"https://aoctrl.com/schneider/ATV9B0C40T4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9B0C40T4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900 series, ATV9B0C40T4 modular AC drive, 600 hp normal duty / 500 hp heavy duty at 480 V, cabinet mount, IP00 for cabinet integration.","salesMarkdown":"## 600 hp at 480 V — normal and heavy duty profiles The ATV9B0C40T4 is a modular Altivar Process ATV900 drive rated 600 hp at 480 V in normal duty and 500 hp at 480 V in heavy duty, with corresponding line currents of 578 A and 484 A. The heavy-duty profile gives you headroom for constant-torque loads like conveyors or extruders where the motor draws full current across the speed range. ## Built-in safety and EMC compliance The drive also carries an integrated EMC filter rated for 300 m cable runs to IEC 61800-3 category C3, which covers most industrial installations without an add-on filter. Total harmonic current distortion (THDI) is below 5 % at full load per IEEE 519, so it won't cause nuisance tripping on shared distribution transformers. ## Fieldbus and I/O expansion The drive ships with dual RJ45 Ethernet IP/Modbus TCP ports and one RJ45 Modbus serial port. For Profibus DP, PROFINET, EtherCAT, DeviceNet, or CANopen, the three option-card slots (A, B, C) accept the corresponding communication modules. Slot B also accepts encoder interface modules (digital 5/12 V, analog, or resolver). ## Switching frequency and derating Switching frequency is adjustable from 2 to 8 kHz, with a derating factor applied above 2.5 kHz. Running at 8 kHz quiets motor whine but reduces continuous output current — budget the derating into the drive sizing if the application is noise-sensitive.","metaTitle":"Schneider ATV9B0C40T4 Altivar Process VFD, 600 HP, 480 V","metaDescription":"Schneider Electric ATV9B0C40T4 Altivar Process ATV900 AC drive, 600 HP normal duty at 480 V. Active production, sourced to order. CE, UL, IEC 61800-5-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"ATV9B0C40T4","Supply":"External supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min, earth","Marking":"CE","Variant":"Modular version","Standards":"IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1","EMC filter":"Integrated 984.3 ft (300 m) IEC 61800-3 category C3","Data format":"8 bits, configurable odd, even or no parity Modbus serial","Noise level":"75 dB 86/188/EEC","Option card":"Slot A communication module Profibus DP V1 Slot A communication module PROFINET Slot A communication module DeviceNet Slot A communication module CANopen daisy chain RJ45 Slot A communication module CANopen SUB-D 9 Slot A communication module CANopen screw terminals Slot A communication module EtherCAT Slot A/slot B/slot C digital and analog I/O extension module Slot A/slot B/slot C output relay extension module Slot B 5/12 V digital encoder interface module Slot B analog encoder interface module Slot B resolver encoder interface module","description":"variable speed drive APM, ATV900, Low Harmonic/Regen drive, 480 V, 600 hp","Line current":"578.0 A 480 V normal duty) 484.0 A 480 V heavy duty) 501.6 A 480 V regenerative mode normal duty) 415.8 A 480 V regenerative mode heavy duty)","Maximum THDI":"<5 % full load IEEE 519","Mounting mode":"Cabinet mount","Apparent power":"480.0 kVA at 480 V normal duty 402.0 kVA at 480 V heavy duty 417.0 kVA at 480 V normal duty regenerative mode 345.7 kVA at 480 V heavy duty regenerative mode","Connector type":"2 RJ45 Ethernet IP/Modbus TCP on terminal 1 RJ45 Modbus serial on terminal","Motor power hp":"600.0 hp at 480 V normal duty 500.0 hp at 480 V heavy duty 600.0 hp at 480 V normal duty regenerative mode 500.0 hp at 480 V heavy duty regenerative mode","Kit composition":"1 control unit mechanical mounting kits power connection set of fuses 3.0 power module 160 kW 2.0 front cover","Protection type":"Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive","Safety function":"STO (safe torque off) SIL 3","Type of cooling":"Forced convection","lifecycle_stage":"current","Method of access":"Slave Modbus TCP","Pollution degree":"2 IEC 61800-5-1","Range of product":"Altivar Process ATV900","Shock resistance":"4 gn 11 ms IEC 60068-2-27","Supply frequency":"50...60 Hz +/- 5 %","Device short name":"ATV9B0","Relative humidity":"5...95 % without condensation IEC 60068-2-3","Transmission rate":"10/100 Mbit/s Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial","Operating altitude":"0...4800 m with current derating above 1000m","Physical interface":"2-wire RS 485 Modbus serial","Transmission frame":"RTU Modbus serial","Number of addresses":"1...247 Modbus serial","Product destination":"Synchronous motors Asynchronous motors","Switching frequency":"2.5...8 kHz with derating factor 2...8 kHz adjustable","Degree of protection":"UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)","Frequency resolution":"Display unit 0.1 Hz Analog input 0.012/50 Hz","Type of polarization":"No impedance Modbus serial","Vibration resistance":"1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars","IP degree of protection":"IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529","Motor slip compensation":"Adjustable Automatic whatever the load Not available in permanent magnet motor law Can be suppressed","Network number of phases":"3 phases","Continuous output current":"730.0 A at 2.5 kHz normal duty 590.0 A at 2.5 kHz heavy duty 730.0 A at 2.5 kHz normal duty regenerative mode 590.0 A at 2.5 kHz heavy duty regenerative mode","Maximum transient current":"876.0 A 60 s normal duty) 885.0 A 60 s heavy duty) 876.0 A 60 s regenerative mode normal duty) 885.0 A 60 s regenerative mode heavy duty)","Product or component type":"Variable speed drive","[Us] rated supply voltage":"480 V","Communication port protocol":"EtherNet/IP Modbus serial Modbus TCP","Nominal switching frequency":"2.5 kHz","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3","Product specific application":"Process and utilities","Speed drive output frequency":"0.1...599 Hz","Electromagnetic compatibility":"Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6","Synchronous motor control profile":"Permanent magnet motor Synchronous reluctance motor","Asynchronous motor control profile":"Optimized torque mode Variable torque standard Constant torque standard","Acceleration and deceleration ramps":"Linear adjustable separately from 0.01...9999 s S, U or customized","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Permissible temporary current boost":"1.2 x In 60 s normal duty) 1.5 x In 60 s heavy duty)","Ambient air temperature for operation":"23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/th/en/product/download-pdf/ATV9B0C40T4?filename=Schneider+Electric_Altivar-Process-ATV900_ATV9B0C40T4.pdf', 'path_name': '289f85c6671f6e061799556c8e5d41d6.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/289f85c6671f6e061799556c8e5d41d6.pdf', 'status': 1}","sourceUrl":"https://www.se.com/in/en/product/ATV9B0C40T4/variable-speed-drive-apm-atv900-low-harmonic-regen-drive-480-v-600-hp/"},"ai":{"faq":[{"question":"What is ATV9B0C40T4's listed supply for digital inputs and STO?","answer":"The drive provides an external supply for digital inputs at 24 V DC (19...30 V), an internal supply for a reference potentiometer at 10.5 V DC ±5 %, and an internal supply for digital inputs and STO at 24 V DC (21...27 V). Insulation resistance is 1 MOhm at 500 V DC for 1 minute to earth."},{"question":"What compliance documentation does Schneider Electric provide for ATV9B0C40T4?","answer":"The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1. The integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9B0C40T4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9B0C40T4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}