{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9B0C50R4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9B0C50R4","canonicalUrl":"https://aoctrl.com/schneider/ATV9B0C50R4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9B0C50R4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, modular cabinet drive, ATV9B0C50R4, 500 kW normal duty / 400 kW heavy duty at 440 V, 704 A line current, STO SIL 3.","salesMarkdown":"The Schneider Electric ATV9B0C50R4 is a modular cabinet-mount drive from the Altivar Process ATV900 range, rated for 500 kW at 440 V normal duty and 400 kW heavy duty, with a line current of 704 A normal duty and 563 A heavy duty. It carries STO (safe torque off) SIL 3 as a standard safety function and includes an integrated EMC filter compliant with IEC 61800-3 category C3 for cable runs up to 300 m. ## Fieldbus and I/O flexibility Three option slots (A, B, C) accept communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), and EtherCAT. Slot A also handles digital/analog I/O extension or output relay modules; slot B accepts 5/12 V digital encoder or analog encoder or resolver interface modules. The base unit includes dual RJ45 for Ethernet IP/Modbus TCP at 10/100 Mbit/s and one RJ45 for Modbus serial at 4.8 to 38.4 kbit/s, 2-wire RS-485, RTU frame, 1 to 247 addresses. ## Power and motor control Switching frequency is adjustable from 2 to 8 kHz with derating. Motor slip compensation is automatic and adjustable, not available in permanent magnet motor law. The drive handles both synchronous and asynchronous motors. Apparent power at 440 V normal duty is 537 kVA; heavy duty 429 kVA. Total harmonic current distortion (THDI) is under 5% at full load per IEEE 519. Cabinet mount, IP00 (for IP21 or IP54 cabinet integration). Forced convection cooling. Operating altitude 0 to 4800 m with derating above 1000 m. Ambient relative humidity 5 to 95% non-condensing. Vibration resistance: 1.5 mm peak-to-peak at 2 to 13 Hz, 0.5 gn at 13 to 200 Hz. Shock resistance 4 gn for 11 ms. Pollution degree 2 per IEC 61800-5-1.","metaTitle":"Schneider ATV9B0C50R4 Altivar Process ATV900, 500 kW Normal","metaDescription":"Schneider Electric ATV9B0C50R4 Altivar Process ATV900 drive. 500 kW / 704 A at 440 V normal duty, 400 kW heavy duty. STO SIL 3, integrated EMC filter C3. Current lifecycle stage. S","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"704.0 A at 440 V (normal duty) 563.0 A at 440 V (heavy duty) 611.2 A at 440 V regenerative mode (normal duty) 489.0 A at 440 V regenerative mode (heavy duty)","Frequency":"50...60 Hz +/- 5 %","Data Format":"8 bits, configurable odd, even or no parity for Modbus serial","Connector Type":"2 RJ45 for Ethernet IP/Modbus TCP on terminal 1 RJ45 for Modbus serial on terminal","Product Status":"Active","Pollution Degree":"2 conforming to IEC 61800-5-1","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.2 °C","Temperature Storage":"-40...70 °C","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV9B0C50R4/variable-speed-drive-apm-atv900-low-harmonic-regen-drive-440-v-500-kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV9B0C50R4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9B0C50R4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9B0C50R4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}