{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9B0C80Q4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9B0C80Q4","canonicalUrl":"https://aoctrl.com/schneider/ATV9B0C80Q4","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9B0C80Q4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar Process ATV900, modular variable speed drive, ATV9B0C80Q4, 800 kW at 400 V normal duty, 630 kW heavy duty, IP00, forced convection cooling.","salesMarkdown":"The ATV9B0C80Q4 is a modular Altivar Process ATV900 drive sized for 800 kW at 400 V normal duty and 630 kW at 400 V heavy duty, with matching line currents of 1227 A and 971 A respectively. Regenerative-mode ratings are also specified: 800 kW / 1087 A normal duty, 630 kW / 851.6 A heavy duty. Apparent power runs 850 kVA at 400 V normal duty and 673 kVA heavy duty; regenerative modes deliver 753.1 kVA and 590 kVA respectively. The drive handles both synchronous and asynchronous motors. Switching frequency is adjustable from 2 to 8 kHz, with a derating factor applied above 2.5 kHz. The integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs. ## Integration notes Cabinet-mount design, IP00 rated (requires IP21 or IP54 cabinet integration per IEC 61800-5-1). Forced convection cooling; noise level 78 dB. Operating altitude up to 4800 m with current derating above 1000 m. Three option-card slots (A, B, C) accept communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherCAT, plus digital/analog I/O and relay extension modules. Slot B also supports encoder interfaces (digital 5/12 V, analog, resolver). Safety function: STO (safe torque off) rated SIL 3. Protection covers motor and drive thermal, phase break, short-circuit, overvoltage, undervoltage, overspeed, and control circuit break. ## Fieldbus & control Dual RJ45 ports for Ethernet IP/Modbus TCP (10/100 Mbit/s), plus one RJ45 for Modbus serial (4.8 to 38.4 kbit/s, RTU frame, 2-wire RS 485, 1 to 247 addresses). Supply for digital inputs and STO: 24 V DC (21...27 V). External supply for digital inputs: 24 V DC (19...30 V). Internal reference potentiometer supply: 10.5 V DC ±5 %.","metaTitle":"Schneider Electric ATV9B0C80Q4 Altivar Process ATV900, 800 k","metaDescription":"Schneider Electric ATV9B0C80Q4 Altivar Process ATV900 drive, 800 kW at 400 V normal duty, 630 kW heavy duty. Active lifecycle. Integrated EMC filter C3. STO SIL 3. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Current":"1227.0 A at 400 V (normal duty) 971.0 A at 400 V (heavy duty) 1087.0 A at 400 V regenerative mode (normal duty) 851.6 A at 400 V regenerative mode (heavy duty)","Frequency":"50...60 Hz +/- 5 %","Data Format":"8 bits, configurable odd, even or no parity for Modbus serial","Connector Type":"2 RJ45 for Ethernet IP/Modbus TCP on terminal 1 RJ45 for Modbus serial on terminal","Product Status":"Active","Pollution Degree":"2 conforming to IEC 61800-5-1","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.2 °C","Temperature Storage":"-40...70 °C","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/ATV9B0C80Q4/variable-speed-drive-apm-atv900-low-harmonic-regen-drive-400-v-800-kw/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV9B0C80Q4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9B0C80Q4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9B0C80Q4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}