{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATV9B0M12T6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATV9B0M12T6","canonicalUrl":"https://aoctrl.com/schneider/ATV9B0M12T6","factsUrl":"https://aoctrl.com/api/mcp/products/ATV9B0M12T6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Altivar Process ATV900, modular VFD, ATV9B0M12T6, 1200 hp at 600 V normal duty, 1000 hp heavy duty, STO SIL 3, integrated EMC filter C3.","salesMarkdown":"The Schneider ATV9B0M12T6 is an active-production Altivar Process ATV900 modular drive sized for a 1200 hp motor at 600 V normal duty, or 1000 hp heavy duty. It ships as a kit: control unit, power module (200 kW), mechanical mounting kit, power connection set with fuses, and front cover. The lifecycle stage is current — no end-of-life notice on record, so this is the line item to spec into a BOM without worrying about a last-time-buy window. Line current at 600 V normal duty is 937 A; heavy duty pulls 785 A. That puts it squarely in the 1000–1200 hp induction or synchronous motor class. The apparent power numbers — 973 kVA normal, 815 kVA heavy — confirm the transformer and cable sizing a site engineer needs to coordinate. Switching frequency is adjustable 2–4.9 kHz with derating; no one is running this at 4.9 kHz on a 1000 hp load without watching the thermal curve. ## Safety and compliance stack The integrated EMC filter meets IEC 61800-3 category C3 for 300 m of motor cable, which covers most industrial panel-to-motor runs without an external filter. Standards list includes UL 61800-5-1, so the UL Type 1 or Type 12 cabinet integration is straightforward for North American panels. ## Fieldbus and I/O flexibility The drive comes with dual RJ45 ports for Ethernet IP / Modbus TCP (10/100 Mbit/s) and one RJ45 for Modbus serial (RTU at 4.8–38.4 kbit/s). Slot A accepts optional Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT communication modules. Slots A/B/C also take digital/analog I/O or output relay extensions. That means the same drive can slot into a PROFINET line today and migrate to EtherCAT next year by swapping one card.","metaTitle":"Schneider ATV9B0M12T6 Altivar Process ATV900, 1200 HP","metaDescription":"Active ATV9B0M12T6 VFD from Schneider Altivar Process ATV900 series. Rated 1200 HP at 600 V normal duty, STO SIL 3, integrated EMC filter. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Frequency":"50...60 Hz +/- 5 %","Product Status":"Active","Pollution Degree":"Pollution degree 2","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"1.2 °C","Temperature Storage":"-40...158 °F (-40...70 °C)","Main Product Or Component Type":"Variable speed drive"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/ATV9B0M12T6/variable-speed-drive-altivar-process-atv900-apm-low-harmonic-regen-600-v-1200-hp/","alternativesUrl":"https://aoctrl.com/api/mcp/products/ATV9B0M12T6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATV9B0M12T6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATV9B0M12T6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}