{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"ATVRU75N4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"ATVRU75N4","canonicalUrl":"https://aoctrl.com/schneider/ATVRU75N4","factsUrl":"https://aoctrl.com/api/mcp/products/ATVRU75N4","rawCanonicalId":null},"summary":{"shortDescription":"SCHNEIDER ELECTRIC Variable Frequency Drive: 500V, 10 hp Max Output Power, 18.4 A Max Output Current","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"6.9 in (175 mm)","Phase":"3 phase","Width":"3.1 in (80 mm)","Height":"13.3 in (337 mm)","Category":"US1CP4B22184","Standards":"IEC 61800-5-1 IEC 61800-3","Fixing Mode":"By screws","Input power":"6.8 kW 380...500 V AC voltage inputs continuous) 10.2 kW 380...500 V AC voltage inputs transient for 60 s)","Input current":"16.5 A 380 V AC voltage inputs continuous) 14.5 A 500 V AC voltage inputs continuous) 22.9 A 380 V AC voltage inputs transient for 60 s) 19.1 A 500 V AC voltage inputs transient for 60 s)","Output Current":"13.4 A 380 V AC continuous) 11.9 A 500 V AC continuous) 18.4 A 380 V AC transient for 60 s) 15.4 A 500 V AC transient for 60 s)","Type of cooling":"Fan","lifecycle_stage":"unknown","Pollution degree":"2 IEC 61800-5-1","Range of Product":"Altivar","Rated power in W":"6.8 kW","Network Frequency":"45...65 Hz","Device Application":"Energy regeneration","Operating altitude":"3280.84...9842.52 ft (1000...3000 m) with power derating 1 % per 100 m","Operating position":"Vertical or horizontal position","Electrical connection":"Control removable screw terminal block 0.5...1.5 mm², AWG 20...AWG 16 bottom) Power supply removable screw terminal block 2.5...4 mm², AWG 12...AWG 10 top) DC bus removable screw terminal block 2.5...4 mm², AWG 12...AWG 10 bottom)","Nbr. of units in pkg.":"1","Maximum DC bus voltage":"300...880 V DC","Product or Component Type":"Power module","[Us] rated supply voltage":"380...500 V - 15...10 %","Environmental characteristic":"Chemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S2 IEC 60721-3-3","[Ue] rated operational voltage":"456...778 V DC","Maximum voltage drop at rated load":"3 %","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"14...122 °F (-10...50 °C) without derating 122...140 °F (50...60 °C) with derating factor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$665.48","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d19f6165a4c0947a6a952c77df097416.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/ATVRU75N4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/ATVRU75N4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/ATVRU75N4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}