{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"BMEAHI0812H","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"BMEAHI0812H","canonicalUrl":"https://aoctrl.com/schneider/BMEAHI0812H","factsUrl":"https://aoctrl.com/api/mcp/products/BMEAHI0812H","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Modicon X80 analog input module, BMEAHI0812H, 8 channels 4–20 mA HART with broken wire detection and conformal coating.","salesMarkdown":"The Schneider Modicon X80 BMEAHI0812H is an 8-channel analog input module handling 4–20 mA current loops with built-in HART communication and per-channel broken wire detection. The point-to-point topology keeps each field device on its own dedicated return path, so a fault on one loop stays electrically isolated from the others. Broken wire detection flags an open circuit before the controller sees a saturated or erratic value — useful for catching a cut cable or a failed transmitter before it causes a process excursion. Channel-to-channel isolation is rated at 1000 V DC for 60 seconds; isolation to ground and the backplane bus is even higher at 1400 V DC. A transient on one input will not propagate to its neighbors. Compliance covers UL 61010-2-201, CSA C22.2 No 61010-2-201, IEC 61010-2-201, and ATEX directive 2014/34/EU. It also carries marine type approval per IACS and substation EMC per IEC 61850-3.","metaTitle":"Schneider BMEAHI0812H Modicon X80 8-Ch HART AI Module","metaDescription":"Active 8-channel 4–20 mA analog input module with HART and broken wire detection. Point-to-point topology, 1000 V channel isolation, conformal coating. IEC 61131-2, UL 61010-2-201,","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Checks":"Broken wire detection","Topology":"Point-to-point","Standards":"IEC 61131-2 IEC 61010-2-201 UL 61010-2-201 CSA C22.2 No 61010-2-201 IACS E10 IEC 61000-6-5, interface type 1 and type 2 IEC 61850-3, location G IEC 60079-0","Directives":"2014/35/EU - low voltage directive 2014/30/EU - electromagnetic compatibility 2014/34/EU - ATEX directive","Input impedance":"250 Ohm internally protective resistor (3.6 to 50 Ohm)","lifecycle_stage":"current","Range of product":"Modicon X80","Isolation voltage":"1000 V DC for 60 s between channels 1400 V DC for 60 s between channels and ground 1400 V DC for 60 s between channels and bus","Measurement error":"0.15 % of full scale 25 °C 0.55 % of full scale - 25...70 °C","Temperature drift":"50 ppm/°C","Function available":"I/O mapping","Operating altitude":"0...2000 m 2000...5000 m with derating factor","Analogue input type":"Current 4...20 mA","Protective treatment":"Conformal coating","Analogue input number":"8","Electrical connection":"20 ways terminal block Telefast","Application specific I/O":"HART","Analogue input resolution":"15 bits + sign","Product or component type":"Analog input module","Isolation between channels":"Isolated","Environmental characteristic":"Gas resistant class Gx conforming to ISA S71.04 Gas resistant class 3C4 conforming to IEC 60721-3-3 Dust resistant class 3S4 conforming to IEC 60721-3-3 Sand resistant class 3S4 conforming to IEC 60721-3-3 Salt resistant level 2 conforming to IEC 68252 Mold growth resistant class 3B2 conforming to IEC 60721-3-3 Fungal spore resistant class 3B2 conforming to IEC 60721-3-3 Hazardous location class I division 2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$957.58","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/725870b872af46a24ec7931e6cfe7c46.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/BMEAHI0812H/alternatives.json"},"ai":{"faq":[{"question":"Does this module support broken wire detection?","answer":"Yes, the module checks each analog input for an open circuit and flags it, enabling early detection of a failed transmitter or damaged cable."},{"question":"What is the topology of the BMEAHI0812H?","answer":"The module uses point-to-point topology, meaning each channel has its own dedicated return path."},{"question":"What compliance certifications does the BMEAHI0812H carry?","answer":"It complies with IEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201, IACS, IEC 61850-3, and ATEX (2014/34/EU)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/BMEAHI0812H","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/BMEAHI0812H when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}