{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"BMXAMM0600H","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"BMXAMM0600H","canonicalUrl":"https://aoctrl.com/schneider/BMXAMM0600H","factsUrl":"https://aoctrl.com/api/mcp/products/BMXAMM0600H","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric, Modicon X80 series, mixed analog I/O module, order code BMXAMM0600H. Four analog inputs and two analog outputs, conformal-coated for severe environments, with voltage and current ranges covering 0-20 mA, 4-20 mA, ±10 V, 0-10 V, 0-5 V and 1-5 V.","salesMarkdown":"## What the module is, and what it actually scans The Schneider Electric BMXAMM0600H is a mixed analog I/O module in the Modicon X80 range, carrying 4 analog inputs and 2 analog outputs on a single 20-way connector with an IP20 rating, and is qualified for severe environments via conformal coating. The input stage accepts current 0-20 mA, current 4-20 mA, voltage ±10 V, voltage 0-10 V, voltage 0-5 V and voltage 1-5 V; the output stage drives current 0-20 mA, current 4-20 mA and voltage ±10 V. Temperature drift sits at 100 ppm/°C on every output range, 30 ppm/°C on the voltage inputs (±10 V, 0-10 V, 0-5 V, 1-5 V) and 50 ppm/°C on the 0-20 mA and 4-20 mA inputs — a useful spec to keep on hand when justifying a calibration interval to an auditor. Conversion time is ≤2 ms, the nominal read cycle is 5 ms for 4 channels, and the fast read cycle runs 1 ms + 1 ms per channel used, which is what the application logic actually sees when it polls the module. ## Resolution, isolation, and the wiring story Input resolution is 12 bits on 0-20 mA, 4-20 mA, 0-5 V and 1-5 V, 13 bits on 0-10 V and 14 bits on ±10 V; output resolution is 11 bits on 0-20 mA and 4-20 mA and 12 bits on ±10 V. Common-mode rejection is 80 dB, and the channel-to-channel path is non-isolated — the 1400 V DC barrier sits between channels and ground and between channels and the backplane, with 750 V DC between grouped I/O channels. Permitted input overload is ±30 mA on the current ranges and ±30 V on every voltage range, and the maximum conversion envelope tops out at ±11.25 V on the ±10 V ranges, 0-30 mA on the current inputs and 0-24 mA on the current outputs — useful to confirm before pointing the module at a misconfigured transmitter. ## Power, backplane, and cabinet footprint The module draws 240 mA at 3.3 V DC from the backplane and dissipates 2.6 W typical / 3.2 W maximum at 24 V DC (0.35 W typical / 0.48 W maximum at 3.3 V DC) — a sensible line item for a rack power budget. Front-face wiring lands on a single 20-way connector and the module slots into the standard X80 rack as an IP20 build, so panel layout and cable routing follow the usual Modicon X80 conventions. Operating altitude is 0-2000 m unrestricted and 2000-5000 m with a derating factor; relative humidity tolerance is 5-95% at 55 °C without condensation. ## Diagnostics, filtering, and recovery behaviour Front-panel indication is one green RUN LED, one green channel-diagnostic LED per channel, a red ERR LED and a red I/O LED — enough granularity to point a commissioning engineer at the offending channel without pulling out a terminal. Input recalibration is handled internally in firmware, outputs are factory calibrated, filtering is a first-order digital filter implemented in firmware, and the fallback mode is configurable between predefined and user-defined states, so a comms-loss event can be made to hold last value or drive to a safe output. ## Compliance, environment, and the 'H' suffix The part is held to IEC 61010-2-201, IEC 61131-2, UL 61010-2-201 and CSA C22.2 No 61010-2-201, and is declared against the 2014/35/EU low-voltage and 2014/30/EU electromagnetic-compatibility directives. The 'H' suffix denotes the severe-environments variant: conformal-coated, rated gas-resistant class Gx and class 3C4, dust/sand resistant class 3S4, salt resistant level 2, and mold growth / fungal spore resistant class 3B2 — which is the reason this code, not the standard BMXAMM0600, is on marine, offshore, wastewater and similar panels. Mechanical robustness is 30 gn shock resistance and 3 gn vibration resistance, with an MTBF figure of 1,400,000 hours.","metaTitle":"Schneider BMXAMM0600H Modicon X80 Analog I/O, 4AI/2AO, Harsh","metaDescription":"Schneider BMXAMM0600H Modicon X80 mixed analog I/O module, 4 inputs / 2 outputs, severe-environment coated, current production. 0.25% FS accuracy at 25 °C; RFQ to source.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Standards":"IEC 61010-2-201 IEC 61131-2 UL 61010-2-201 CSA C22.2 No 61010-2-201","Directives":"2014/35/EU - low voltage directive 2014/30/EU - electromagnetic compatibility","Status LED":"1 LED (green) RUN 1 LED per channel (green) channel diagnostic 1 LED (red) ERR 1 LED (red) I/O","Input level":"High level","Output level":"High level","Fallback mode":"Predefined Configurable","Recalibration":"Internal on inputs Factory calibrated on outputs","Type of filter":"First order digital filtering by firmware","Conversion time":"<= 2 ms","Input impedance":"250 Ohm","lifecycle_stage":"current","MTBF reliability":"1400000 H","Range of product":"Modicon X80","Shock resistance":"30 gn","Isolation voltage":"1400 V DC between channels and ground 1400 V DC between channels and bus 750 V DC between group of I/O channels","Measurement error":"0.25 % of full scale 0...20 mA 25 °C output 0.25 % of full scale 4...20 mA 25 °C output 0.25 % of full scale +/- 10 V 25 °C output 0.25 % of full scale +/- 10 V 25 °C input 0.25 % of full scale 0...10 V 25 °C input 0.25 % of full scale 0...5 V 25 °C input 0.25 % of full scale 1...5 V 25 °C input 0.35 % of full scale 0...20 mA 25 °C input 0.35 % of full scale 4...20 mA 25 °C input <= 0.8 % of full scale 4...20 mA - 25...70 °C output","Relative humidity":"5...95 % at 55 °C without condensation","Temperature drift":"100 ppm/°C +/- 10 V output 100 ppm/°C 0...20 mA output 100 ppm/°C 4...20 mA output 30 ppm/°C +/- 10 V input 30 ppm/°C 0...10 V input 30 ppm/°C 0...5 V input 30 ppm/°C 1...5 V input 50 ppm/°C 0...20 mA input 50 ppm/°C 4...20 mA input","Operating altitude":"0...2000 m 2000...5000 m with derating factor","Analogue input type":"Current 0...20 mA Current 4...20 mA Voltage +/- 10 V Voltage 0...10 V Voltage 0...5 V Voltage 1...5 V","Current consumption":"240 mA at 3.3 V DC","Analogue output type":"Current: 0...20 mA Current: 4...20 mA Voltage: +/- 10 V","Fast read cycle time":"1 ms + 1 ms x number of channels used","Protective treatment":"Conformal coating","Vibration resistance":"3 gn","Analogue input number":"4","Common mode rejection":"80 dB","Electrical connection":"20 ways 1 connector","Analogue output number":"2","Power consumption in W":"2.6 W 24 V DC typical 3.2 W 24 V DC maximum 0.35 W 3.3 V DC typical 0.48 W 3.3 V DC maximum","IP degree of protection":"IP20","Nominal read cycle time":"5 ms for 4 channels","Maximum conversion value":"+/- 11.25 V +/- 10 V output +/- 11.25 V +/- 10 V input 0...30 mA 0...20 mA input 0...30 mA 4...20 mA input +/- 11.25 V 0...10 V input +/- 11.25 V 0...5 V input +/- 11.25 V 1...5 V input 0...24 mA 0...20 mA output 0...24 mA 4...20 mA output","Analogue input resolution":"12 bits 0...20 mA 12 bits 0...5 V 12 bits 1...5 V 12 bits 4...20 mA 13 bits 0...10 V 14 bits +/- 10 V","Product or component type":"Mixed analog I/O module","Analogue output resolution":"11 bits, 0...20 mA 11 bits, 4...20 mA 12 bits, +/- 10 V","Isolation between channels":"Non isolated","Environmental characteristic":"Gas resistant class Gx Gas resistant class 3C4 Dust resistant class 3S4 Sand resistant class 3S4 Salt resistant level 2 Mold growth resistant class 3B2 Fungal spore resistant class 3B2 Hazardous location","Permitted overload on inputs":"+/- 30 mA 0...20 mA +/- 30 mA 4...20 mA +/- 30 V +/- 10 V +/- 30 V 0...10 V +/- 30 V 0...5 V +/- 30 V 1...5 V","Product specific application":"For severe environments","Minimum crosstalk attenuation":"70 dB","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","Precision of internal conversion resistor":"0.1 % - 15 ppm/°C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$373.38 – $853.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/176dca48b0fb65043eaf1eddc2347feb.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/BMXAMM0600H/alternatives.json"},"ai":{"faq":[{"question":"What standards and directives does the BMXAMM0600H carry?","answer":"The module is listed to IEC 61010-2-201, IEC 61131-2, UL 61010-2-201 and CSA C22.2 No 61010-2-201, and is declared against the 2014/35/EU low-voltage and 2014/30/EU electromagnetic-compatibility directives."},{"question":"What accuracy can I expect from the BMXAMM0600H on a 4-20 mA loop?","answer":"Per the data, the 4-20 mA output sits at 0.25% of full scale at 25 °C and ≤0.8% of full scale across the -25 to 70 °C operating span, with a temperature drift of 100 ppm/°C; the 4-20 mA input is 0.35% of full scale at 25 °C with 50 ppm/°C drift."},{"question":"What makes the BMXAMM0600H the 'H' or severe-environments variant?","answer":"The 'H' suffix denotes the conformal-coated severe-environments build, rated gas resistant class Gx and 3C4, dust/sand resistant 3S4, salt resistant level 2, and mold-growth / fungal-spore resistant 3B2 — the specifier's choice for marine, offshore, wastewater and similar installations."},{"question":"How many channels does the BMXAMM0600H provide and over which connector?","answer":"Four analog inputs and two analog outputs land on a single 20-way connector, with an IP20 rating, and the input stage accepts 0-20 mA, 4-20 mA, ±10 V, 0-10 V, 0-5 V and 1-5 V while the outputs drive 0-20 mA, 4-20 mA and ±10 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/BMXAMM0600H","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/BMXAMM0600H when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}