{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"BMXART0814","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"BMXART0814","canonicalUrl":"https://aoctrl.com/schneider/BMXART0814","factsUrl":"https://aoctrl.com/api/mcp/products/BMXART0814","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon X80 analog input module, BMXART0814, 8 channels, RTD/thermocouple/mV/V, sigma-delta 16-bit, isolated channels.","salesMarkdown":"## Integration notes The BMXART0814 is an 8-channel analog input module that sits in a Modicon X80 (M340) rack. It accepts thermocouples (B, E, J, K, L, N, R, S, T, U), RTDs (Pt100, Pt1000, Ni100, Ni1000, Cu10), and voltage inputs from ±40 mV to ±1.28 V. Each channel is isolated from the others, which saves grounding gymnastics in multi-sensor panels. The sigma-delta converter gives 15 bits plus sign resolution. Read cycle is 400 ms for RTDs and 200 ms for thermocouples—fast enough for process loops, not for high-speed anvils. Current draw is 150 mA at 3.3 V and 50 mA at 24 V; budget accordingly in the rack power supply. Connection is via dual 40-pin connectors. The module carries IP20, operates from 0 to 60 °C, and survives 30 gn shock and 3 gn vibration—rated for industrial panel environments. ## Compliance summary The module holds IEC 61131-2 (PLC standard), IEC 61000-6-4 (emission), IEC 61000-6-2 (immunity), and EN 61010-2-201 (safety) compliance. It also meets the Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU. These are the documents typically asked for in panel certification audits.","metaTitle":"Schneider BMXART0814 Modicon X80 Analog Input Module, 8 chan","metaDescription":"Active 8-channel analog input module for Modicon X80 (M340). Supports RTD, thermocouple, mV, V. Sigma-delta 16-bit ADC, isolated channels. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Standards":"IEC 61131-2 IEC 61000-6-4 IEC 61000-6-2 EN 61010-2-201","Directives":"2014/35/EU - low voltage directive 2014/30/EU - electromagnetic compatibility","Status LED":"1 LED (green) RUN 1 LED per channel (green) channel diagnostic 1 LED (red) ERR 1 LED (red) I/O","Input level":"Low level","Recalibration":"Internal","Detection type":"Open circuit Cu 10 Open circuit Ni 100 Open circuit Ni 1000 Open circuit Pt 100 Open circuit Pt 1000 Open circuit thermocouple B Open circuit thermocouple E Open circuit thermocouple J Open circuit thermocouple K Open circuit thermocouple L Open circuit thermocouple N Open circuit thermocouple R Open circuit thermocouple S Open circuit thermocouple T Open circuit thermocouple U","Type of filter":"First order digital filtering","lifecycle_stage":"current","MTBF reliability":"900000 H","Range of product":"Modicon X80","Shock resistance":"30 gn","Measurement error":"+/- 0.7 °C Ni 1000 25 °C +/- 2 °C Pt 100 0...60 °C +/- 2 °C Pt 1000 0...60 °C +/- 2.1 °C Ni 100 25 °C +/- 2.1 °C Pt 100 25 °C +/- 2.1 °C Pt 1000 25 °C +/- 2.7 °C thermocouple U 25 °C +/- 2.8 °C thermocouple J 25 °C +/- 3 °C Ni 100 0...60 °C +/- 3 °C thermocouple L 25 °C +/- 3.2 °C thermocouple R 25 °C +/- 3.2 °C thermocouple S 25 °C +/- 3.5 °C thermocouple B 25 °C +/- 3.7 °C thermocouple E 25 °C +/- 3.7 °C thermocouple K 25 °C +/- 3.7 °C thermocouple N 25 °C +/- 3.7 °C thermocouple T 25 °C +/- 4 °C Cu 10 0...60 °C +/- 4 °C Cu 10 25 °C +/- 4.5 °C thermocouple J 0...60 °C +/- 4.5 °C thermocouple L 0...60 °C +/- 4.5 °C thermocouple R 0...60 °C +/- 4.5 °C thermocouple S 0...60 °C +/- 4.5 °C thermocouple U 0...60 °C +/- 5 °C thermocouple B 0...60 °C +/- 5 °C thermocouple E 0...60 °C +/- 5 °C thermocouple K 0...60 °C +/- 5 °C thermocouple N 0...60 °C +/- 5 °C thermocouple T 0...60 °C 0.05 % of full scale +/- 1.28 V 25 °C 0.05 % of full scale +/- 160 mV 25 °C 0.05 % of full scale +/- 320 mV 25 °C 0.05 % of full scale +/- 40 mV 25 °C 0.05 % of full scale +/- 640 mV 25 °C 0.05 % of full scale +/- 80 mV 25 °C 0.12 % of full scale 400 Ohm 25 °C 0.12 % of full scale 4000 Ohm 25 °C 1.3 °C Ni 1000 0...60 °C","Relative humidity":"5...95 % at 55 °C without condensation","Temperature drift":"25 ppm/°C 400 Ohm 25 ppm/°C 4000 Ohm 25 ppm/°C Ni 1000 25 ppm/°C thermocouple B 25 ppm/°C thermocouple E 25 ppm/°C thermocouple J 25 ppm/°C thermocouple K 25 ppm/°C thermocouple L 25 ppm/°C thermocouple N 25 ppm/°C thermocouple R 25 ppm/°C thermocouple S 25 ppm/°C thermocouple T 25 ppm/°C thermocouple U 30 ppm/°C +/- 1.28 V 30 ppm/°C +/- 160 mV 30 ppm/°C +/- 320 mV 30 ppm/°C +/- 40 mV 30 ppm/°C +/- 640 mV 30 ppm/°C +/- 80 mV 30 ppm/°C Cu 10 30 ppm/°C Ni 100 30 ppm/°C Pt 100 30 ppm/°C Pt 1000","Operating altitude":"0...2000 m 2000...5000 m with derating factor","Analogue input type":"Voltage +/- 1.28 V Voltage +/- 160 mV Voltage +/- 320 mV Voltage +/- 40 mV Voltage +/- 640 mV Voltage +/- 80 mV Resistor 400 Ohm 2 wires Resistor 400 Ohm 3 wires Resistor 400 Ohm 4 wires Resistor 4000 Ohm 2 wires Resistor 4000 Ohm 3 wires Resistor 4000 Ohm 4 wires Temperature probe -100...+260 °C Cu 10 Temperature probe -100...+450 °C Pt 100 conforming to UL/JIS Temperature probe -100...+450 °C Pt 1000 conforming to UL/JIS Temperature probe -200...+850 °C Pt 100 conforming to IEC Temperature probe -200...+850 °C Pt 1000 conforming to IEC Temperature probe -60...+180 °C Ni 100 Temperature probe -60...+180 °C Ni 1000 Thermocouple +130...+1820 °C thermocouple B Thermocouple +270...+1300 °C thermocouple N Thermocouple -200...+600 °C thermocouple U Thermocouple -200...+760 °C thermocouple J Thermocouple -200...+900 °C thermocouple L Thermocouple -270...+1000 °C thermocouple E Thermocouple -270...+1370 °C thermocouple K Thermocouple -270...+400 °C thermocouple T Thermocouple -50...+1769 °C thermocouple R Thermocouple -50...+1769 °C thermocouple S","Current consumption":"150 mA at 3.3 V DC 50 mA at 24 V DC","Protective treatment":"Standard version","Vibration resistance":"3 gn","Analogue input number":"8","Common mode rejection":"120 dB 50/60 Hz","Electrical connection":"40 ways 2 connectors","Measurement resolution":"0.1 °C Cu 10 0.1 °C Ni 100 0.1 °C Ni 1000 0.1 °C Pt 100 0.1 °C Pt 1000 0.1 °C thermocouple B 0.1 °C thermocouple E 0.1 °C thermocouple J 0.1 °C thermocouple K 0.1 °C thermocouple L 0.1 °C thermocouple N 0.1 °C thermocouple R 0.1 °C thermocouple S 0.1 °C thermocouple T 0.1 °C thermocouple U 1280/2exp14 mV +/- 1.28 V 160/2exp14 mV +/- 160 mV 320/2exp14 mV +/- 320 mV 40/2exp14 mV +/- 40 mV 12.5 mOhm 400 Ohm 125 mOhm 4000 Ohm 640/2exp14 mV +/- 640 mV 80/2exp14 mV +/- 80 mV","IP degree of protection":"IP20","Nominal read cycle time":"400 ms with temperature probe 200 ms with thermocouple","Maximum conversion value":"+/- 100 % 400 Ohm +/- 100 % 4000 Ohm +/- 102.5 % +/- 1.28 V +/- 102.5 % +/- 160 mV +/- 102.5 % +/- 320 mV +/- 102.5 % +/- 40 mV +/- 102.5 % +/- 640 mV +/- 102.5 % +/- 80 mV","Analog/digital conversion":"Sigma delta 16 bits","Analogue input resolution":"15 bits + sign","Maximum wiring resistance":"20 Ohm 2 wires Cu 10 20 Ohm 2 wires Ni 100 20 Ohm 2 wires Pt 100 20 Ohm 3 wires Cu 10 20 Ohm 3 wires Ni 100 20 Ohm 3 wires Pt 100 200 Ohm 2 wires Ni 1000 200 Ohm 2 wires Pt 1000 200 Ohm 3 wires Ni 1000 200 Ohm 3 wires Pt 1000 50 Ohm 4 wires Cu 10 50 Ohm 4 wires Ni 100 50 Ohm 4 wires Pt 100 500 Ohm 4 wires Ni 1000 500 Ohm 4 wires Pt 1000","Product or component type":"Analog input module","Cold junction compensation":"External by Pt100 probe","Isolation between channels":"Isolated","Differential mode rejection":"60 dB 50/60 Hz","Environmental characteristic":"3C3 conforming to IEC 60721-3-3 3C4 conforming to IEC 60721-3-3","Permitted overload on inputs":"+/- 7.5 V +/- 1.28 V +/- 7.5 V +/- 160 mV +/- 7.5 V +/- 320 mV +/- 7.5 V +/- 40 mV +/- 7.5 V +/- 640 mV +/- 7.5 V +/- 80 mV","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"0...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$560.00 – $577.85","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c03f76f097f0308b65dff5da1a7b22af.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/BMXART0814/alternatives.json"},"ai":{"faq":[{"question":"What standards does the BMXART0814 comply with?","answer":"It complies with IEC 61131-2, IEC 61000-6-4, IEC 61000-6-2, and EN 61010-2-201."},{"question":"What directives apply?","answer":"The module is designed to meet the Low Voltage Directive 2014/35/EU and the EMC Directive 2014/30/EU."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/BMXART0814","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/BMXART0814 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}