{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"BMXCPS4002S","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"BMXCPS4002S","canonicalUrl":"https://aoctrl.com/schneider/BMXCPS4002S","factsUrl":"https://aoctrl.com/api/mcp/products/BMXCPS4002S","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Modicon X80 BMXCPS4002S redundant power supply module, 240 V AC, 15 W, 0.55 A input, IP20, conformal coated, active.","salesMarkdown":"## Overview The BMXCPS4002S is a Schneider Modicon X80 redundant power supply module, order code BMXCPS4002S, rated for 240 V AC input at 60 Hz, delivering 15 W. It draws 0.55 A and carries IP20 protection with conformal coating. This module is in active production. Schneider lists the BMXCPS4002S as an active product with no announced end-of-life. For current lead time and pricing, submit an RFQ — the module is sourced through standard distribution channels.","metaTitle":"Schneider BMXCPS4002S Modicon X80 redundant power supply, 240 V AC, 15 W","metaDescription":"Schneider Modicon X80 BMXCPS4002S redundant power supply module, 240 V AC, 15 W, 0.55 A input, IP20, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Standards":"IEC 61131-2 IEC 61010-2-201 UL 61010-2-201 CSA C22.2 No 61010-2-201 IACS E10 EN/IEC 61000-6-5, interface type 1 and type 2 EN/IEC 61850-3, location G IEC 60079-0","Directives":"2014/30/EU - electromagnetic compatibility 2006/42/EC - machinery 2014/34/EU - ATEX directive","Status LED":"1 LED (green) presence of voltages (OK) 1 LED (green) redundancy OK 1 LED (green) power supply status","Control type":"RESET push-button cold restart","Input current":"0.55 A 230 V 1.1 A 115 V","Apparent power":"0.13 kVA","Inrush current":"30 A 115 V 60 A 230 V","Product weight":"0.51 kg","Primary voltage":"100...240 V","Protection type":"Internal fuse not accessible for primary circuit Overload protection for secondary circuit Overvoltage protection for secondary circuit Short-circuit protection for secondary circuit","Secondary power":"15 W 3.3 V DC at -25...60 °C I/O module logic power supply 40 W 24 V DC at -25...60 °C I/O module power supply and processor if 3.3 V not loaded","lifecycle_stage":"current","It on activation":"0.1 A.s 115 V 0.15 A.s 230 V","MTBF reliability":"792000 H","Range of product":"Modicon X80","Shock resistance":"15 gn","I2t on activation":"1 A².s 115 V 4 A².s 230 V","Network frequency":"50/60 Hz","Relative humidity":"5...95 % at 55 °C without condensation","Operating altitude":"0...2000 m 2000...5000 m with derating factor","Dielectric strength":"1500 V primary/secondary I/O module logic power supply 1500 V primary/secondary I/O module power supply and processor 2300 V primary/secondary sensor power supply 1500 V primary/ground 500 V 24 V sensor output/ground","Supply circuit type":"AC","Protective treatment":"Conformal coating","Vibration resistance":"3 gn","Electrical connection":"1 connector 2 pin(s)alarm relay 1 connector 5 pin(s)line supply, protective earth","Insulation resistance":">= 100 MOhm primary/ground >= 100 MOhm primary/secondary","Primary voltage limit":"85...264 V","Backplane Compatibility":"All backplane","IP degree of protection":"IP20","Immunity to microbreaks":"10 ms","Network frequency limits":"47...63 Hz","Product or component type":"Power supply module","Current at secondary voltage":"4.5 A 3.3 V DC I/O module logic power supply 1.67 A 24 V DC I/O module power supply and processor","Environmental characteristic":"Hazardous location class I division 2 Gas resistant class Gx conforming to ISA S71.04 Gas resistant class 3C4 conforming to IEC 60721-3-3 Dust resistant class 3S4 conforming to IEC 60721-3-3 Sand resistant class 3S4 conforming to IEC 60721-3-3 Salt resistant level 2 conforming to IEC 68252 Mold growth resistant class 3B2 conforming to IEC 60721-3-3 Fungal spore resistant class 3B2 conforming to IEC 60721-3-3","Maximum power dissipation in W":"8.5 W","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","Advanced Diagnostics Available Via Network":"Redundancy information Redundancy test Temperature sensing Remaining lifetime Uptime duration"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$596.90 – $1,343.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/de410ed5e4039455820c825016a9ab85.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/BMXCPS4002S/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/BMXCPS4002S","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/BMXCPS4002S when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}