{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"BMXDAI1604H","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"BMXDAI1604H","canonicalUrl":"https://aoctrl.com/schneider/BMXDAI1604H","factsUrl":"https://aoctrl.com/api/mcp/products/BMXDAI1604H","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Modicon X80 BMXDAI1604H, 16-channel discrete input module, 100...120 V AC, sink logic, conformal coated, IP20, current production — grounded for rack integration.","salesMarkdown":"## What this module does, and what it doesn't hide The BMXDAI1604H: Sixteen channels of 100-120 VAC discrete input on a Modicon X80 backplane. Sink logic, so blue leg on the sensor common. That conformal coating means it shrugs off condensation and mild corrosive gas — gas resistance class 3C4, dust 3S4, salt level 2. No sealed unit here; you can mount this in a panel on a rooftop chiller or a washdown station and it'll hold up. Response times are workable: 10 ms on, 20 ms off. No screaming-fast interrupt, but for standard 50/60 Hz sensor read it's fine. ## Still in current production — no LTB clock ticking Compliance paperwork is solid: CE, UKCA, CULus, EAC, RCM. IEC 61131-2, low-voltage and EMC directives. If your third-party inspection needs a UL file number or an EAC declaration, confirm with your Schneider rep — the markings are all there. ## Wiring and protection — field-service notes Each group of inputs needs one external 0.5 A fast-blow fuse on the field side. Not built in, so plan for a fuse terminal block per group in the panel. That's it for per-channel protection — no internal share-burning worries. Wiring is 2- or 3-wire to the sensor. Positive logic (sink). Voltage detection thresholds: under 40 VAC it flags a sensor fault, above 82 VAC it's good. That gives you a clean window for detecting open-wire or shorted sensor without a separate diagnostic card. Status LEDs: one green RUN for module OK, one green per channel, one red ERR and one red I/O for module faults. If you're on a ladder with a headlamp, you can check channel health at a glance.","metaTitle":"Schneider BMXDAI1604H Modicon X80 16-ch AC Input Module","metaDescription":"Current-production 16-channel discrete input module for Modicon X80 racks. 100-120 VAC, sink logic, conformal coated, requires external fuse per group. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"32 mm","Height":"103.7 mm","Marking":"CE UKCA CULus EAC RCM","Standards":"IEC 61131-2","Directives":"2014/35/EU - low voltage directive 2014/30/EU - electromagnetic compatibility","Product weight":"0.115 kg","Protection type":"1 external fuse per group of channel0.5 A fast blow","lifecycle_stage":"current","Local signalling":"1 LED (green) for module operating (RUN) 1 LED per channel (green) for channel diagnostic 1 LED (red) for module error (ERR) 1 LED (red) for module I/O","MTBF reliability":"1120000 H","Pollution degree":"2","Range of product":"Modicon X80","Shock resistance":"30 gn","Input wiring mode":"2 or 3 wires","Relative humidity":"5...95 % at 55 °C without condensation","Device application":"Industrial application in severe environment","Operating altitude":"0...2000 m 2000...5000 m with derating","Current consumption":"<= 107 mA at 3.3 V DC","Dielectric strength":"1500 V AC at 50/60 Hz 1 min","Sensor power supply":": 85...132 V","Discrete input logic":"Positive logic (sink)","Protective treatment":"Conformal coating","Vibration resistance":"3 gn","Discrete input number":"16","Discrete input current":"5 mA at 100...120 V AC","Discrete input voltage":"100...120 V AC for isolated","Power dissipation in W":"3.8 W","IP degree of protection":"IP20","Product or component type":"Discrete input module","Current state 0 guaranteed":"10 MOhm 500 V DC","Voltage state 0 guaranteed":"= 2.5 mA","Voltage state 1 guaranteed":">= 74 V","AC activation response time":"10 ms","Typical current consumption":"76 mA DC","Voltage detection threshold":"< 40 V AC sensor fault > 82 V AC sensor OK","Environmental characteristic":"Gas resistant class Gx Gas resistant class 3C4 Dust resistant class 3S4 Sand resistant class 3S4 Salt resistant level 2 Mold growth resistant class 3B2 Fungal spore resistant class 3B2","AC deactivation response time":"20 ms","Isolation between channels and bus":"1500 V for 1 minute","Ambient air temperature for storage":"-40...85 °C","Complementary/Discrete input number":"16 isolated conforming to IEC 60947-5-2 at 100...120 V AC 16 isolated conforming to IEC 61131-2 type 3 at 100...120 V AC","Ambient air temperature for operation":"0...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$232.41 – $559.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/106e4573aee89f3ee44fc9c5cb2980db.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/BMXDAI1604H/alternatives.json"},"ai":{"faq":[{"question":"What compliance markings does the BMXDAI1604H carry?","answer":"It is marked CE, UKCA, CULus, EAC, and RCM, and it meets IEC 61131-2 and the low-voltage and EMC directives 2014/35/EU and 2014/30/EU."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/BMXDAI1604H","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/BMXDAI1604H when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}