{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"BMXEIA0100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"BMXEIA0100","canonicalUrl":"https://aoctrl.com/schneider/BMXEIA0100","factsUrl":"https://aoctrl.com/api/mcp/products/BMXEIA0100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon X80 BMXEIA0100, AS-Interface master module, M4 master profile, SUB-D 3-pin connector, standard module format, 0.34 kg.","salesMarkdown":"## What lands in the rack The Schneider Electric BMXEIA0100 is an AS-Interface master module in the Modicon X80 family, addressed to the rack over a single male SUB-D, 3-pin connector on the front face. Module format is Standard, drawing 160 mA at 3.3 V DC from the backplane — count it against the rack power budget the same way you would any other X80 drop. It carries the M4 master profile and addresses S7.3, S7.A.7, S7.A.A, S7.A.8, S7.A.9, and S6.0.X slave profiles on the AS-i segment. The front face exposes the diagnostics the field tech needs without a laptop: RUN (green), ERR (red), A/B group (green), I/O fault (red), 32 channel diagnostics LEDs, ASI power (green), and fault (red). ## Bus sizing and cycle time Cycle time is 5 ms for 31 slaves and 10 ms for 62 slaves — the headline 5 ms figure is the small-segment case, and the bus doubles its scan period once you cross 31 devices. Up to 124 server devices fit on a standard-addressing segment for discrete or analog I/O; extended addressing lifts the discrete ceiling to 496 server devices, while analog stays at 124 in extended mode. Maximum cable distance between devices is 100 m on the trunk, 200 m with a line extension, 300 m with 2 repeaters, and 500 m with 2 repeaters placed with the master at the middle of the run. ## Where it sits in the panel IP20 rating and 0...60 °C operating envelope with -40...70 °C storage, qualified for hazardous location class I division 2 — mount inside the cabinet, not in the field. Compliance pack drops straight into the decl file: IEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201, IACS, IEC 61000-6-5 interface types 1 and 2, IEC 61850-3 location G, and IEC 60079-0, under EU directives 2014/35/EU (LV), 2014/30/EU (EMC), and 2014/34/EU (ATEX).","metaTitle":"BMXEIA0100 Modicon X80 AS-i master, M4 profile","metaDescription":"Schneider BMXEIA0100 Modicon X80 AS-Interface master module, M4 profile, 124/496 slaves, 5 ms cycle. Active, sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Standards":"IEC 61131-2 IEC 61010-2-201 UL 61010-2-201 CSA C22.2 No 61010-2-201 IACS E10 IEC 61000-6-5, interface type 1 and type 2 IEC 61850-3, location G IEC 60079-0","Addressing":"Standard and extended","Cycle time":"5 ms for 31 10 ms for 62","Directives":"2014/35/EU - low voltage directive 2014/30/EU - electromagnetic compatibility 2014/34/EU - ATEX directive","Module format":"Standard","Product weight":"0.34 kg","lifecycle_stage":"current","Local signalling":"1 LED (green) for module active (RUN) 1 LED (red) for module error (ERR) 1 LED (green) for displays the group of 31 slaves (A/B) 1 LED (red) for I/O module fault (I/O) 32 LEDs for diagnostics of the AS-Interface and each slave 1 LED (green) for ASI power 1 LED (red) for fault","Range of product":"Modicon X80","Current consumption":"160 mA at 3.3 V DC","Electrical connection":"1 male connector SUB-D, 3 pins","IP degree of protection":"IP20","Product or component type":"Master module","Number of server device(s)":"124 server device(s) for discrete inputs and outputs - standard 124 server device(s) for analog inputs and outputs - standard 496 server device(s) for discrete inputs and outputs - extended 124 server device(s) for analog inputs and outputs - extended","Environmental characteristic":"Hazardous location class I division 2","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"0...60 °C","Maximum cable distance between devices":"100 m 200 m line extension 300 m 2 repeaters 500 m 2 repeaters and the master at the middle","Actuator sensor interface profile [AS-i]":"M4 master profile S7.3 slave profile S7.A.7 slave profile S7.A.A slave profile S7.A.8 slave profile S7.A.9 slave profile S6.0.X slave profile"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$323.85 – $737.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f78c28767ea6ca23a3990d1fe5ef80bc.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/BMXEIA0100/alternatives.json"},"ai":{"faq":[{"question":"What standards does BMXEIA0100 carry?","answer":"IEC 61131-2, IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201, IACS, IEC 61000-6-5 interface types 1 and 2, IEC 61850-3 location G, and IEC 60079-0, under EU directives 2014/35/EU (LV), 2014/30/EU (EMC), and 2014/34/EU (ATEX)."},{"question":"What addressing modes does BMXEIA0100 support?","answer":"Standard and extended — extended mode is what unlocks the higher slave count on the AS-i segment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/BMXEIA0100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/BMXEIA0100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}