{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"BMXERT1604H","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"BMXERT1604H","canonicalUrl":"https://aoctrl.com/schneider/BMXERT1604H","factsUrl":"https://aoctrl.com/api/mcp/products/BMXERT1604H","rawCanonicalId":null},"summary":{"shortDescription":"Schneider BMXERT1604H Electric. Full specifications and sourcing options are below.","salesMarkdown":"## Overview The BMXERT1604H is a Schneider Modicon X80 multifunction input module, order code BMXERT1604H, providing 4 channels for time-synchronized digital/analog acquisition at 24 V DC or 125 V DC. It is designed for severe environments with conformal coating and resistance to gas, dust, salt, and mold. This module synchronizes plant-wide events via DCF77 or IRIG-B time-code input, stamping acquired data with 1 ms resolution. Acquisition runs at 1 ms per channel with a 0.5 ms sampling duration, and the anti-bounce filter is configurable from 0 to 255 ms to suppress contact chatter on dry contacts or proximity sensors. Hot-swap capability allows module replacement without powering down the rack — critical for line-up maintenance. Sixteen input-status LEDs plus RUN, ERR, T, and I/O LEDs give immediate visual feedback on module health and signal state. ## Applications The BMXERT1604H is specified for process and utility automation in harsh environments — offshore platforms, chemical plants, water treatment, and power substations — where gas (class Gx, class 3C4), dust (class 3S4), salt (level 2), and mold (class 3B2) resistance is required. It fits Modicon X80 racks in Schneider Electric Programmable Logic Controller systems. The BMXERT1604H carries an active lifecycle status — currently in production with no end-of-life announcement from Schneider Electric. Standard lead times apply; confirm current availability and minimum order quantities via RFQ.","metaTitle":"Schneider BMXERT1604H Modicon X80 Multifunction Input Module","metaDescription":"Schneider BMXERT1604H Modicon X80 multifunction input module, 4 channels, 24/125 V DC, DCF77/IRIG-B time sync, 1 ms acquisition, severe environment rated.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"32 mm","Height":"100 mm","Standards":"IEC 61131-2 IEC 61010-2-201 UL 61010-2-201 CSA C22.2 No 61010-2-201 IACS E10 EN/IEC 61000-6-5, interface type 1 and type 2 EN/IEC 61850-3, location G","Directives":"2014/35/EU - low voltage directive 2014/30/EU - electromagnetic compatibility","Data recording":"1 ms time stamps","lifecycle_stage":"current","Acquisition time":"1 ms","Local signalling":"1 LED (green) for firmware and module run (RUN) 1 LED (green) for status of time code input (T) 1 LED (red) for module fault (ERR) 1 LED (red) for power supply interruption (I/O) 16 LEDs for input status (0...15)","Range of product":"Modicon X80","Group of channels":"4 groups of 4 inputs for process input","Isolation voltage":"2500 V DC for 60 s bus to discrete input 1400 V DC for 60 s bus to IRIG/DCF 2500 V DC for 60 s discrete input to IRIG/DCF","Relative humidity":"95 % without condensation","Sampling duration":"0.5 ms","Switching voltage":"125 V at 1.3 mA for process input 110 V at 1.3 mA for process input 60 V at 2.5 mA for process input 48 V at 2.5 mA for process input 24 V at 6.7 mA for process input","Function available":"Hot swap","Operating altitude":"0...2000 m 2000...5000 m","Current consumption":"30 mA at 24 V DC 130 mA at 3.3 V DC","Protective treatment":"Conformal coating","Anti bounce filtering":"Configurable from 0 to 255 ms","Product or component type":"Multifunction input module","[Us] rated supply voltage":"24 V DC (voltage range: 19...30 V) 48...60 V DC (voltage range: 38...75 V) 110...125 V DC (voltage range: 88...156 V)","Environmental characteristic":"Gas resistant class Gx conforming to ISA S71.04 Gas resistant class 3C4 conforming to IEC 60721-3-3 Dust resistant class 3S4 conforming to IEC 60721-3-3 Sand resistant class 3S4 conforming to IEC 60721-3-3 Salt resistant level 2 conforming to IEC 68252 Mold growth resistant class 3B2 conforming to IEC 60721-3-3 Fungal spore resistant class 3B2 conforming to IEC 60721-3-3 Hazardous location class I division 2","Time synchronisation protocol":"DCF77 IRIG-B","Maximum power consumption in W":"4 W for process input","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,973.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c247c1ae3db2f7ee6aeaaecfbcba9ca6.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/BMXERT1604H/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/BMXERT1604H","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/BMXERT1604H when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}