{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"BMXPRA0100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"BMXPRA0100","canonicalUrl":"https://aoctrl.com/schneider/BMXPRA0100","factsUrl":"https://aoctrl.com/api/mcp/products/BMXPRA0100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Modicon X80 peripheral remote I/O adaptor, BMXPRA0100, 1 Ethernet/IP port, Modbus TCP, real-time clock, 448 kB memory, 95 mA at 3.3 V DC, -25…70°C, IP20.","salesMarkdown":"The BMXPRA0100 is a peripheral remote I/O adaptor in the Modicon X80 range – it connects a remote drop of X80 I/O modules to a controller via a single Ethernet/IP port carrying Modbus TCP. The module draws 95 mA from the rack backplane and dissipates 2.3 W, leaving headroom for additional I/O slices in the same rack. It carries a real-time clock and dual memory: 448 kB internal, plus a removable 96 kB card for program retention or data logging. The clock stays alive with the rack supply – no separate battery to schedule. Operating temperature spans -25…70°C, which covers most untreated cabinets and outdoor installations within 2000 m altitude. Storage range is -40…85°C. Hazardous location approval (Class I Div 2) and ATEX Directive 2014/34/EU compliance let you install the adaptor in Zone 2 or Division 2 environments without an additional purge or enclosure. The BMXCRA31210 is the nearest alternative: both are X80 remote I/O adaptors. BMXPRA0100 has one Ethernet/IP port with Modbus TCP; BMXCRA31210 has three ports and supports ring topology (RSTP).","metaTitle":"Schneider BMXPRA0100 Modicon X80 Remote I/O Adaptor, 1 Port","metaDescription":"Schneider BMXPRA0100 active peripheral remote I/O adaptor for Modicon X80. 1 Ethernet/IP port, Modbus TCP, 95 mA, -25…70°C, ATEX, 448 kB memory. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Marking":"CE","Standards":"IEC 61131-2 IEC 61010-2-201 UL 61010-2-201 CSA C22.2 No 61010-2-201 IACS E10 IEC 61000-6-5, interface type 1 and type 2 IEC 61850-3, location G IEC 60079-0","Directives":"2014/35/EU - low voltage directive 2014/30/EU - electromagnetic compatibility 2014/34/EU - ATEX directive","Module format":"Standard","Number of port":"1","Realtime clock":"With","Memory capacity":"448 kB internal 96 kB removable","lifecycle_stage":"current","Local signalling":"1 LED (green) for module active (RUN) 1 LED (red) for module error (ERR) 1 LED (red) for external fault (I/O) 1 LED (green) for activity on Ethernet network (ETH ACT) 1 LED (red) for memory card fault (CARD ERR) 1 LED (green) for Ethernet link diagnostics (STS) 1 LED (green) for Ethernet network status (link)","Range of product":"Modicon X80","Relative humidity":"95 % without condensation","Operating altitude":"<= 2000 m","Application structure":"1 master task","Power dissipation in W":"2.3 W","IP degree of protection":"IP20","Average consumption in mA":"95 mA","Product or component type":"Peripheral remote I/O adaptor","Integrated connection type":"Ethernet/IP for device network","Maximum altitude transport":"3000 m","Communication port protocol":"Modbus TCP","Environmental characteristic":"Hazardous location class I division 2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$428.97 – $1,248.75","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6de155fe3b3f3d67bcaa0926e34fef84.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/BMXPRA0100/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source — BMXCRA31210?","answer":"The BMXCRA31210 is the most comparable Modicon X80 remote I/O adaptor, but it differs in port count (3 vs 1), power consumption (1200 mA vs 95 mA), and operating temperature range (0…60°C vs -25…70°C). It adds ring topology support. It is not a pin‑compatible drop‑in without reviewing the network architecture and rack power budget."},{"question":"What compliance marks does BMXPRA0100 carry?","answer":"CE marking, plus full compliance with low‑voltage (2014/35/EU), EMC (2014/30/EU), and ATEX (2014/34/EU) directives. Standards include IEC 61131‑2, IEC 61010‑2‑201, UL 61010‑2‑201, CSA C22.2 No 61010‑2‑201, IACS, IEC 61000‑6‑5, IEC 61850‑3, and IEC 60079‑0. The module is suitable for Class I Division 2 hazardous locations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/BMXPRA0100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/BMXPRA0100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}