{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"BMXSAI0410","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"BMXSAI0410","canonicalUrl":"https://aoctrl.com/schneider/BMXSAI0410","factsUrl":"https://aoctrl.com/api/mcp/products/BMXSAI0410","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon X80 BMXSAI0410, Safety Analog Input Module, 4 channels 4-20 mA, Isolated, High Speed, IP20, 16-bit conversion.","salesMarkdown":"The BMXSAI0410 is a 4-channel analog input module in the Modicon X80 platform, built to take 4-20 mA current signals from field transmitters. It's a high-speed, isolated card — conversion runs at 6 ms for all four channels, and each input is isolated from the others and from ground at 1500 V DC. That isolation kills ground-loop noise that can wander into a non-isolated card when you've got pumps on different transformers. Accuracy is ≤0.3% of full scale from -25 to 60 °C. Temperature drift is 30 ppm/°C, and the module uses second-order digital filtering. Overload protection: inputs can survive a sustained 25 mA without damage. That matters when a loop gets mistakenly jumpered to a 24 V supply — this card won't blow its input resistor the way a cheaper one would. The 16-bit ADC gives you resolution down to 2 µA, which is plenty for picking up small process changes. Environmental rating is better than the typical PLC card: shock resistance 15 gn, vibration 3 gn, operating humidity up to 95% at 55 °C without condensation. It's rated for gas class 3C4, dust class 3S4, salt level 2, and mold/fungal spore resistance — handy if the cabinet is half a mile from a cooling tower or near a cement kiln. ## Power, connection, and diagnostics Power draw is modest — 200 mA at 3.3 V DC (from the backplane) plus 115 mA at 24 V DC for the loop side. Connector is a single 20-way plug, so pre-wiring the panel and swapping the card later is straightforward. Status LEDs: one green RUN, one red ERR, and one green per channel for diagnostics — you can see which loop is alive at a glance without opening the programming software. Input impedance is 286 Ohm, which means a standard 24 V loop can drive a 4-20 mA signal through a long cable drop without starving the card. Default digital scaling gives ±10000 counts over the range (user scale up to ±32000). No external recalibration needed — the module handles it internally.","metaTitle":"BMXSAI0410 Modicon X80 Analog Input Module, 4-Ch 4-20mA Isol","metaDescription":"Schneider BMXSAI0410 active-analog-input module: 4 channels, 4-20mA isolated, 16-bit, 6-ms scan, UL/CSA/IEC certified. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Standards":"CSA C22.2 No 61010-2-201 IEC 61131-2 IEC 61010-2-201 UL 61010-2-201","Status LED":"1 LED (green) RUN 1 LED per channel (green) channel diagnostic 1 LED (red) ERR 1 LED (red) I/O","Input level":"High level","Recalibration":"Internal","Type of filter":"Second order digital filtering","Input impedance":"286 Ohm","lifecycle_stage":"current","MTBF reliability":"463000 H","Range of product":"Modicon X80","Shock resistance":"15 gn","Isolation voltage":"500 V DC between channels 1500 V DC between channels and ground 1500 V DC between channels and bus","Measurement error":"<= 0.3 % of full scale 4...20 mA - 25...60 °C","Relative humidity":"5...95 % at 55 °C without condensation","Temperature drift":"30 ppm/°C 4...20 mA","Operating altitude":"0...2000 m 2000...5000 m with derating factor","Analogue input type":"Current 4...20 mA","Current consumption":"200 mA at 3.3 V DC 115 mA at 24 V DC","Digital value format":"+/- 32000 in user scale +/- 10000 by default","Vibration resistance":"3 gn","Analogue input number":"4","Electrical connection":"20 ways 1 connector","Measurement resolution":"2 µA 4...20 mA","IP degree of protection":"IP20","Nominal read cycle time":"6 ms for 4 channels","Maximum conversion value":"0...25 mA 4...20 mA","Analog/digital conversion":"16 bits","Analogue input resolution":"13 bits 0...12500 counts","Product or component type":"Analog input module","Isolation between channels":"Isolated","Environmental characteristic":"Gas resistant class Gx Gas resistant class 3C4 Dust resistant class 3S4 Sand resistant class 3S4 Salt resistant level 2 Mold growth resistant class 3B2 Fungal spore resistant class 3B2 Fungal spore resistant class 3B2 conforming to IEC 60721-3-3","Permitted overload on inputs":"25 mA 4...20 mA","Minimum crosstalk attenuation":"120 dB","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","Precision of internal conversion resistor":"0.1 % - 15 ppm/°C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$514.35 – $949.20","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/562223d1acdfa7e13b1439da8d6e5766.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/BMXSAI0410/alternatives.json"},"ai":{"faq":[{"question":"What standards does the BMXSAI0410 comply with?","answer":"It carries certifications under CSA C22.2 No 61010-2-201, IEC 61131-2, IEC 61010-2-201, and UL 61010-2-201."},{"question":"What are the key specifications of the BMXSAI0410?","answer":"Four isolated 4-20 mA inputs, 16-bit conversion, 6 ms scan time for all channels, accuracy ≤0.3% FS, drift 30 ppm/°C, 1500 V DC isolation between channels and to ground."},{"question":"What status LEDs are on the module?","answer":"One green RUN LED, one red ERR LED, and one green channel-diagnostic LED per input channel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/BMXSAI0410","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/BMXSAI0410 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}