{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C063H360FM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C063H360FM","canonicalUrl":"https://aoctrl.com/schneider/C063H360FM","factsUrl":"https://aoctrl.com/api/mcp/products/C063H360FM","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NS new generation, C063H360FM, 3P fixed MCCB, 630 A, MicroLogic 6.0 electronic trip unit, H breaking capacity (70 kA at 415 V AC), manually operated, IP40, IK07.","salesMarkdown":"The C063H360FM is a 3-pole fixed-mount ComPacT NS new generation MCCB rated 630 A at 50 °C with a MicroLogic 6.0 electronic trip unit. The trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground-fault) protection — the G function is built into the trip unit logic, though the breaker ships without earth-leakage relay hardware (without). Breaking capacity is the headline: 85 kA Icu at 240 V AC, 70 kA at 415 V, 65 kA at 440 V, 50 kA at 500/525 V, and 42 kA at 690 V. For a 630 A main breaker on a 2000 kVA transformer at 415 V, that 70 kA covers the prospective fault current without cascading upstream. The breaker is manually operated (no motor mechanism), fixed-mounted to a backplate, with front-front connection (line and load both front). Connection pitch is 70 mm. IP40 enclosure protection and IK07 impact resistance — suitable for indoor panel installation where occasional tool contact is expected, not washdown. Standards compliance: EN/IEC 60947-2 (Category B), suitability for isolation per the same standard. ## Durability and deployment context Mechanical durability is 10,000 cycles; electrical durability varies with load: 2000 cycles at 690 V at full In, 4000 cycles at 690 V at In/2, 5000 cycles at 440 V at In, 6000 cycles at 440 V at In/2. For a main breaker that operates infrequently (once per shift or less), that is ample. For a switching duty application (frequent load disconnect), the electrical endurance at 440 V In/2 (6000 cycles) is the limiting figure. Thermal memory is 20 minutes — after a trip, the MicroLogic 6.0 remembers the thermal state for 20 minutes, so a reclose before that window sees a shorter time-to-trip on the next overload. This matters for motor starting or inrush-heavy loads where successive starts could nuisance-trip without the memory reset. Operating altitude: 0–2000 m no derating; 2000–5000 m with derating. Relative humidity 0–95%. Power losses are 10 W at rated current — negligible for panel thermal budgeting.","metaTitle":"Schneider Electric C063H360FM ComPacT NS 630A 3P MCCB, 85 kA","metaDescription":"Schneider Electric C063H360FM ComPacT NS new generation MCCB, 630 A, MicroLogic 6.0 trip unit, 85 kA Icu at 240 V AC, EN/IEC 60947-2. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"147 mm","Poles":"3P","Width":"210 mm","Height":"327 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Manually operated","Product Status":"Active","Terminal Pitch":"70 mm","Trip Unit Type":"Electronic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Utilization Category":"Category B","Connection Surface Top":"Front","Electrical Life Cycles":"2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2","Mechanical Life Cycles":"10000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/741871c222e7d8ea76b0af511f9eab4d.pdf","sourceUrl":"https://www.se.com/ie/en/product/C063H360FM/circuit-breaker-compact-ns630bh-70ka-at-415vac-3p-fixed-manually-operated-micrologic-6-0-control-unit-630a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C063H360FM/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C063H360FM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C063H360FM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}