{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C063N360FM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C063N360FM","canonicalUrl":"https://aoctrl.com/schneider/C063N360FM","factsUrl":"https://aoctrl.com/api/mcp/products/C063N360FM","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NS new generation, C063N360FM, 3P fixed circuit breaker, 630 A, MicroLogic 6.0 electronic trip unit, 50 kA Icu at 415 V AC, manually operated.","salesMarkdown":"The Schneider Electric C063N360FM is a ComPacT NS new generation fixed-mount circuit breaker, rated 630 A at 50 °C with a MicroLogic 6.0 electronic trip unit. It's a three-pole unit (3P) built to EN/IEC 60947-2, giving you LSI protection — overload (long time), short-time short-circuit, and instantaneous short-circuit — plus ground-fault (G) on the same trip unit. Breaking capacity lands at 85 kA Icu at 240 V AC and holds at 50 kA Icu at 415 V AC — that's the N breaking capacity code, meaning it's sized for most distribution panels where the fault current doesn't exceed 50 kA at 415 V. ## Ratings that matter for the install The 630 A frame is the same physical size as the rest of the ComPacT NS630b...1600 range — 210 mm wide, 327 mm tall, 147 mm deep — so if you're swapping out an older NS630b, the footprint and backplate mounting holes line up. The fixed-mount version bolts directly to a backplate; no DIN rail here, so plan for a drilled panel. Power losses are 10 W steady-state, which is low enough that you don't need forced ventilation in a standard IP40 enclosure. Thermal memory is 20 minutes — after a trip, the MicroLogic 6.0 remembers the thermal history for that window, so a hot restart won't nuisance-trip on a second start. Mounts on a backplate with a 70 mm connection pitch. Front connections both top and bottom — upside and downside — so straight-through busbar layouts work without flipping the breaker. IK07 impact rating means it survives a tool drop during commissioning. Four red LEDs for fault indication, one yellow for overload — you can read the trip cause at a glance without pulling the cover. Manually operated, no motor operator fitted as standard, but the range supports add-on rotary handles and shunt trips if you need remote trip.","metaTitle":"Schneider Electric C063N360FM ComPacT NS Circuit Breaker, 63","metaDescription":"Schneider Electric C063N360FM ComPacT NS new generation circuit breaker. 630 A rated current, MicroLogic 6.0 trip unit, 50 kA Icu at 415 V AC. Current production, available to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","Depth (D)":"147 mm","Standards":"EN/IEC 60947-2","Width (W)":"210 mm","Height (H)":"327 mm","Control type":"Manually operated","Network type":"AC","Power losses":"10 W","Product name":"ComPacT NS new generation","Mounting mode":"Fixed","Thermal memory":"20 mn","Trip unit name":"MicroLogic 6.0","Number of poles":"3P","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"current","Connection pitch":"70 mm","Local signalling":"4 LEDs (red) for fault indication 1 LED (yellow) for overload","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"ComPacT NS630b...1600 new generation","Trip unit rating":"630 A at 50 °C","Breaking capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Network frequency":"50/60 Hz","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"630 A at 50 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Electronic","Utilisation category":"Category B","Electrical durability":"2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2","Mechanical durability":"10000 cycles","Breaking capacity code":"N 50 kA 415 V AC","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Protected poles description":"3D","Auxiliary contact composition":"1 NO/NC","[Ui] rated insulation voltage":"800 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"12.5...600 s at 1.5 x Ir 0.5...24 s at 6 x Ir 0.7...16.6 s at 7.2 x Ir","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","[Tsd] Short-Time Delay Adjustment Range":"0.1...0.4 s I²t=on 0...0.4 s I²t=off","[Icw] rated short-time withstand current":"19.2 kA 1 s conforming to IEC 60947-2","[Ig] ground-fault pick-up adjustment range":"0.3...1 x In for In 0.2...1 x In for 400 A < In < 1250 A 500...1200 A for In >= 1250 A","Long-time protection delay adjustment type tr":"Adjustable 9 settings","[tg] Ground-fault time delay adjustment range":"0.1...0.4 s I²t=on 0...0.4 s I²t=off","Short-time protection delay adjustment type tsd":"Adjustable","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Ground-fault protection pick-up adjustment type Ig":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"0.4...1 x In","Instantaneous protection pick-up adjustment type Ii":"Adjustable","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ii] instantaneous protection pick-up adjustment range":"Off 2...15 x In","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/10395122f5de34ebc6c0cf660a0824d5.pdf","sourceUrl":"https://www.se.com/id/en/product/C063N360FM/circuit-breaker-compact-ns630bn-50ka-at-415vac-3p-fixed-manually-operated-micrologic-6-0-control-unit-630a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C063N360FM/alternatives.json"},"ai":{"faq":[{"question":"Who supplies C063N360FM and how is it quoted for volume purchases?","answer":"C063N360FM is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"What is C063N360FM's listed range (ComPacT) on this component line?","answer":"The C063N360FM belongs to the Schneider Electric ComPacT NS new generation range, specifically the ComPacT NS630b...1600 new generation family of fixed-mount, manually operated circuit breakers."},{"question":"What is C063N360FM's listed depth (d) (147 mm) on this component line?","answer":"The C063N360FM has a depth of 147 mm. Combined with a width of 210 mm and height of 327 mm, it fits the standard ComPacT NS630b...1600 footprint for backplate mounting."},{"question":"What compliance documentation does this brand provide for C063N360FM (RoHS, REACH, UL, IEC)?","answer":"The C063N360FM is certified to EN/IEC 60947-2 and carries an IP40 rating per IEC 60529 and IK07 per EN 50102. It is suitable for isolation per EN/IEC 60947-2. Specific RoHS, REACH, and UL documentation should be requested at quote time — the evidence does not list those separately."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C063N360FM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C063N360FM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}