{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C080H360FM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C080H360FM","canonicalUrl":"https://aoctrl.com/schneider/C080H360FM","factsUrl":"https://aoctrl.com/api/mcp/products/C080H360FM","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NS new generation, C080H360FM, 3P 800 A circuit breaker with MicroLogic 6.0 electronic trip unit, 85 kA Icu at 240 V AC, fixed mount.","salesMarkdown":"## What this 800 A breaker brings to a distribution panel The Schneider C080H360FM is a ComPacT NS new generation 3-pole circuit breaker rated 800 A at 50 °C, carrying a MicroLogic 6.0 electronic trip unit. The H breaking capacity code means 85 kA Icu at 220/240 V AC and 70 kA at 380/415 V AC — enough to handle high-fault utility feeds without cascading upstream. The trip unit covers L (long-time overload), S (short-time short-circuit), I (instantaneous), and G (ground fault) protection, all configurable via the front interface. It is manually operated, fixed-mounted to a backplate, and suited for isolation per EN/IEC 60947-2. The 85 kA at 240 V AC matters for North American 208/240 V services — it clears a bolted fault at the main before the let-through energy damages branch devices. The 65 kA at 440 V and 50 kA at 500/525 V cover the higher-voltage distribution common in mining or marine installations. Category B utilization means it is listed for selectivity with other breakers in the same series. Fixed mount to a backplate. Width 210 mm, height 327 mm, depth 147 mm — the depth is the dimension that determines gland-plate clearance in a shallow enclosure. Connection pitch is 70 mm, front-connected both upside and downside. IP40 enclosure rating, IK07 impact resistance. Power dissipation 15 W at rated current — account for that in the panel thermal budget. ## Durability and thermal memory Mechanical endurance is 10 000 cycles. Electrical endurance at full rated current: 2000 cycles at 690 V In, 4000 cycles at 690 V In/2, 5000 cycles at 440 V In, 6000 cycles at 440 V In/2. The MicroLogic 6.0 includes a 20-minute thermal memory — after a trip, it remembers the thermal state of the conductor for that window, preventing nuisance reclose on a still-hot circuit.","metaTitle":"Schneider C080H360FM ComPacT NS 800A, 85 kA Icu 240V AC","metaDescription":"C080H360FM is a Schneider ComPacT NS new generation 3P 800A circuit breaker with MicroLogic 6.0 trip unit. 85 kA Icu at 240V AC, 70 kA at 415V AC. Active production. Sourced to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"147 mm","Poles":"3P","Width":"210 mm","Height":"327 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Manually operated","Product Status":"Active","Terminal Pitch":"70 mm","Trip Unit Type":"Electronic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Utilization Category":"Category B","Connection Surface Top":"Front","Electrical Life Cycles":"2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2","Mechanical Life Cycles":"10000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/14bcf7c11eb16b3fa7c13ac02618d795.pdf","sourceUrl":"https://www.se.com/ie/en/product/C080H360FM/circuit-breaker-compact-ns800h-70ka-at-415vac-3p-fixed-manually-operated-micrologic-6-0-control-unit-800a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C080H360FM/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C080H360FM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C080H360FM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}