{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C100H3WM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C100H3WM","canonicalUrl":"https://aoctrl.com/schneider/C100H3WM","factsUrl":"https://aoctrl.com/api/mcp/products/C100H3WM","rawCanonicalId":null},"summary":{"shortDescription":"Circuit breaker frame, ComPacT NS1000H, 70kA at 415VAC, 1000A, 3P, withdrawable, manually operated, without control unit","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Range":"ComPacT","Depth (D)":"147 mm","Standards":"IEC 60947-2","Width (W)":"236 mm","Height (H)":"260 mm","Control type":"Manually operated","Network type":"AC","Power losses":"50 W","Mounting mode":"Withdrawable","Number of poles":"3P","Protection type":"Without protection","lifecycle_stage":"current","Connection pitch":"70 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"ComPacT NS630b...1600 new generation","Breaking capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Network frequency":"50/60 Hz","Device application":"Distribution","[In] rated current":"1000 A at 50 °C","Overvoltage category":"III","Utilisation category":"Category B","Electrical durability":"2000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2 4000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2 5000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2 6000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2","Mechanical durability":"10000 cycles conforming to IEC 60947-2","Breaking capacity code":"H 70 kA 415 V AC","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP40 conforming to IEC 60529","Product or component type":"Basic frame","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Integral instant protection":"40 kA","[Ui] rated insulation voltage":"800 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"52 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 52 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 48 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 31 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"19.2 kA 1 s conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,945.22 – $4,991.76","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/08a4763146e2cd8fe5a14e2203157af4.pdf","sourceUrl":"https://www.se.com/vn/en/product/C100H3WM/circuit-breaker-frame-compact-ns1000h-70ka-at-415vac-1000a-3p-withdrawable-manually-operated-without-control-unit/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C100H3WM/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C100H3WM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C100H3WM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}