{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C100L320FM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C100L320FM","canonicalUrl":"https://aoctrl.com/schneider/C100L320FM","factsUrl":"https://aoctrl.com/api/mcp/products/C100L320FM","rawCanonicalId":null},"summary":{"shortDescription":"Schneider C100L320FM Compact Ns New Generation — now discontinued, supplied from remaining surplus and broker stock.","salesMarkdown":"## Overview The C100L320FM is a Schneider ComPacT NS new generation 3-pole molded case circuit breaker rated 1000 A at 50 °C with a 150 kA breaking capacity at 690 V AC, carrying a MicroLogic 2.0 electronic trip unit for L and I protection. It is fixed-mounted, manually operated, and complies with EN/IEC 60947-2; the front face is Class II insulated, and the unit includes one NO/NC auxiliary contact. Compared to the C160H320FM, the C100L320FM delivers a higher breaking capacity (150 kA vs 85 kA) but a lower switching current (1000 A vs 1600 A). Pick the C160H320FM when the load exceeds 1000 A and the available fault current stays under 85 kA; stay with the C100L320FM for high-fault panels up to 1000 A.","metaTitle":"Schneider C100L320FM ComPacT NS MCCB, 1000 A, 150 kA","metaDescription":"Schneider C100L320FM ComPacT NS new generation MCCB: 3-pole, 1000 A, 150 kA breaking capacity at 690 V, MicroLogic 2.0 trip unit, IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Range":"ComPacT","Depth (D)":"147 mm","Standards":"EN/IEC 60947-2","Width (W)":"210 mm","Height (H)":"327 mm","Control type":"Manually operated","Network type":"AC","Power losses":"34 W","Product name":"ComPacT NS new generation","Mounting mode":"Fixed","Thermal memory":"20 mn","Trip unit name":"MicroLogic 2.0","Number of poles":"3P","Protection type":"L : for overload protection (long time) I : for instantaneous short-circuit protection","lifecycle_stage":"current","Connection pitch":"70 mm","Local signalling":"4 LEDs (red) for fault indication 1 LED (yellow) for overload","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"ComPacT NS630b...1600 new generation","Trip unit rating":"1000 A at 50 °C","Breaking capacity":"150 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2","Network frequency":"50/60 Hz","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"1000 A at 50 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"2000 cycles at 690 V In 3000 cycles at 690 V In/2 3000 cycles at 440 V In 4000 cycles at 440 V In/2","Mechanical durability":"10000 cycles","Breaking capacity code":"L 150 kA 415 V AC","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Protected poles description":"3D","Auxiliary contact composition":"1 NO/NC","[Ui] rated insulation voltage":"800 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"150 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"12.5...600 s at 1.5 x Ir 0.5...24 s at 6 x Ir 0.7...16.6 s at 7.2 x Ir","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","[Icw] rated short-time withstand current":"19.2 kA 1 s conforming to IEC 60947-2","Long-time protection delay adjustment type tr":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"0.4...1 x In","Instantaneous protection pick-up adjustment type Ii":"Adjustable","[Ii] instantaneous protection pick-up adjustment range":"1.5...10 x Ir","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,687.72","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9b21cc87ff6a697cb474bdee5a3aa7dc.pdf","sourceUrl":"https://www.se.com/ng/en/product/C100L320FM/circuit-breaker-compact-ns1000l-150ka-at-415vac-3p-fixed-manually-operated-micrologic-2-0-control-unit-1000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C100L320FM/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C100L320FM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C100L320FM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}