{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C1034A040","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C1034A040","canonicalUrl":"https://aoctrl.com/schneider/C1034A040","factsUrl":"https://aoctrl.com/api/mcp/products/C1034A040","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX100...250 series, MicroLogic 4.2 AL electronic trip unit, 40 A at 40 °C, 3-pole 3D, LSoI protection with integrated earth-leakage, EN/IEC 60947-2.","salesMarkdown":"## MicroLogic 4.2 AL trip unit for ComPacT NSX100...250 The Schneider Electric C1034A040 is a MicroLogic 4.2 AL electronic trip unit for the ComPacT NSX100...250 range of molded-case circuit breakers. It is a 3-pole (3D protected) unit rated at 40 A at 40 °C, with an operational voltage of 440 V AC at 50/60 Hz. The trip unit provides LSoI protection: long-time overload (L), short-time short-circuit with fixed delay (So), and instantaneous short-circuit (I), plus integrated earth-leakage protection (Class A). ## Protection settings and adjustability The long-time pickup Ir is adjustable across 9 settings from 18 to 40 A, with fixed delay curves: 400 s at 1.5 x Ir, 16 s at 6 x Ir, and 11 s at 7.2 x Ir. Short-time pickup Isd adjusts from 1.5 to 10 x Ir, with a fixed delay. Instantaneous pickup Ii is fixed at 600 A. Earth-leakage sensitivity IΔn and time delay Δt are both adjustable, with Δt selectable from 0 ms, 60 ms, 150 ms, 500 ms, or 1 s. The trip unit is designed to EN/IEC 60947-2, with a pollution degree of 3 per IEC 60947-1 and IP40 front-face protection per IEC 60529. The unit is Class II for electrical shock protection. This is a fixed-mount trip unit for the ComPacT NSX100...250 breaker frame. It occupies the standard 3-pole slot and communicates local status via a flashing green LED (ready), red LED at 105% Ir (overload), orange LED at 90% Ir (pre-alarm), and a yellow indicator for residual current. No zone selective interlocking (ZSI) is provided on this variant. The earth-leakage function can be disabled via the IΔn rotary switch for applications where ground-fault coordination is handled upstream.","metaTitle":"C1034A040 ComPacT NSX MicroLogic 4.2 AL Trip Unit, 40 A, 3P","metaDescription":"C1034A040 ComPacT NSX100...250 MicroLogic 4.2 AL electronic trip unit. 40 A at 40 °C, 3-pole, LSoI protection with integrated earth-leakage. EN/IEC 60947-2. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Voltage":"440 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Product Status":"Active","Trip Unit Type":"Electronic","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Trip unit","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$10.42","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1a7892fbb31cc5276220c97df13d6d54.pdf","sourceUrl":"https://www.se.com/vn/en/product/C1034A040/trip-unit-micrologic-vigi-4-2al-compact-nsx100-160-250-3-poles-electronic-basic-protections-earth-leakage-alarm-40a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C1034A040/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C1034A040","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C1034A040 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}