{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C1034A100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C1034A100","canonicalUrl":"https://aoctrl.com/schneider/C1034A100","factsUrl":"https://aoctrl.com/api/mcp/products/C1034A100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, MicroLogic 4.2 AL electronic trip unit, 100 A at 40 °C, 3-pole 3D, integrated earth-leakage Class A, EN/IEC 60947-2.","salesMarkdown":"The Schneider Electric C1034A100 is a MicroLogic 4.2 AL electronic trip unit for the ComPacT NSX100...250 molded-case circuit breaker platform. It is rated 100 A at 40 °C (Ir adjustable 40–100 A) and designed for 3-pole 3D protection on AC distribution networks at 440 V, 50/60 Hz. The trip unit integrates earth-leakage protection (Class A) with adjustable sensitivity and time delay, and provides LSoI protection functions: long-time overload, short-time short-circuit with fixed delay, and instantaneous short-circuit fixed at 1500 A. The Ir adjustment range of 40–100 A lets you match the trip unit to the actual load current, not just the breaker frame. The instantaneous pickup is fixed at 1500 A (15 x Ir at the maximum Ir setting) — that sets the magnetic-only trip threshold for hard shorts. The short-time pickup Isd is adjustable 1.5–10 x Ir, giving you selectivity coordination with downstream breakers. The integrated earth-leakage (Class A, sensitive to sinusoidal AC and pulsating DC) with adjustable IΔn and Δt (0 ms to 1 s) means you can set nuisance trip delays for inrush or leakage on motor circuits. The C1034A100 is listed as current-production (active lifecycle). No end-of-life notice or successor order code is published by Schneider Electric for this part. ## Integration and deployment This trip unit mounts into a ComPacT NSX100...250 fixed or plug-in breaker chassis. The breaker itself is DIN-rail or panel-mount, so the trip unit goes in as a field-replaceable electronic module — no need to pull the breaker bus. IP40 front face (finger-safe) suits enclosed panel installation; pollution degree 3 per IEC 60947-1 means it tolerates conductive dust in industrial environments. The local signalling LEDs (green ready, red/orange overload, yellow residual current) give immediate status without opening the panel door.","metaTitle":"Schneider Electric C1034A100 ComPacT NSX MicroLogic 4.2 AL T","metaDescription":"Schneider Electric C1034A100 ComPacT NSX MicroLogic 4.2 AL electronic trip unit, 100 A at 40 °C, 3-pole, integrated earth-leakage Class A, EN/IEC 60947-2. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Voltage":"440 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Product Status":"Active","Trip Unit Type":"Electronic","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Trip unit","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$10.42","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bf4a173e66717ebe0698d62742c291fe.pdf","sourceUrl":"https://www.se.com/ng/en/product/C1034A100/trip-unit-micrologic-vigi-4-2al-compact-nsx100250-3-poles-electronic-basic-protections-earth-leakage-alarm-100a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C1034A100/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C1034A100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C1034A100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}