{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C1036M025","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C1036M025","canonicalUrl":"https://aoctrl.com/schneider/C1036M025","factsUrl":"https://aoctrl.com/api/mcp/products/C1036M025","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX series, MicroLogic 6.2 E-M electronic trip unit, order code C1036M025, 25 A at 65 °C, 3P, LSIG protection for motor applications.","salesMarkdown":"The C1036M025 is a MicroLogic 6.2 E-M electronic trip unit from the ComPacT NSX100...250 range, rated 25 A at 65 °C. It fits 3-pole ComPacT NSX circuit breakers and provides LSIG protection — long-time (L), short-time (S), instantaneous (I), and ground-fault (G) — specifically tuned for motor loads. The 25 A rating at 65 °C means it holds its full ampacity even in a warm panel, so no derating headache for a motor circuit that runs near that ambient. Built to EN/IEC 60947-2, this trip unit uses electronic sensing with an LCD display for local readout of energy metering, protection settings, and event logs. Motor tripping classes 5, 10, 20, and 30 are selectable, so you match the overload curve to the motor's thermal withstand. The long-time pickup (Ir) adjusts from 12 to 25 A, and the short-time pickup (Isd) has nine adjustable settings from 5 to 13 x Ir. Ground-fault pickup (Ig) is adjustable as well. Instantaneous pickup (Ii) is fixed. Zone selective interlocking (ZSI) is included, which helps coordinate downstream breakers for faster fault clearing without losing selectivity upstream.","metaTitle":"C1036M025 ComPacT NSX MicroLogic 6.2 E-M Trip Unit, 25 A, 3P","metaDescription":"C1036M025 is an active MicroLogic 6.2 E-M electronic trip unit for ComPacT NSX100...250 breakers. Rated 25 A at 65 °C, LSIG protection, motor application. Sourced to order against","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","title":"C1036M025","Standards":"EN/IEC 60947-2","description":"Trip unit MicroLogic 6.2EM, ComPacT NSX100-250, 3 poles, basic and ground fault protections, motor, energy meter, 25A","Display type":"LCD display","Network type":"AC","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 6.2 E-M","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"current","Local signalling":"Flashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point","Pollution degree":"3 conforming to IEC 60947-1","Range of product":"ComPacT NSX100...250","Trip unit rating":"25 A at 65 °C","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Motor","Type of measurement":"Energy meter","Motor tripping class":"20 30 10 5","Trip unit technology":"Electronic","Communication of data":"Energy metering Protection and alarm settings Time-stamped histories and event tables Instantaneous and demand values Maintenance indicators Demand current and power Power quality Maximeters/minimeters","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Electrical data recording":"Maintenance indicators","Product or component type":"Trip unit","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","Complementary motor protection":"Current unbalance Stalled rotor Underload Protracted starting time","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"With","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"120 s at 1.5 x Ir for trip class 5 6.5 s at 6 x Ir for trip class 5 5 s at 7.2 x Ir for trip class 5 240 s at 1.5 x Ir for trip class 10 13.5 s at 6 x Ir for trip class 10 10 s at 7.2 x Ir for trip class 10 480 s at 1.5 x Ir for trip class 20 26 s at 6 x Ir for trip class 20 20 s at 7.2 x Ir for trip class 20 720 s at 1.5 x Ir for trip class 30","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Ground-fault protection pick-up adjustment type Ig":"Adjustable","[Ir] long-time protection pick-up adjustment range":"12...25 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Isd] Short-time protection pick-up adjustment range":"5...13 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ig] ground-fault protection pick-up adjustment range":"0.6...1 x In for In = 25 A Ig enable on/off","[Ii] instantaneous protection pick-up adjustment range":"425 A","[Tg] Ground-Fault Protection Time Delay Adjustment Range":"0...0.4 s","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$332.55 – $553.78","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a6afd700d7afb05508657787da790975.pdf","sourceUrl":"https://www.se.com/nz/en/product/C1036M025/trip-unit-micrologic-6-2em-compact-nsx100250-3-poles-basic-and-ground-fault-protections-motor-energy-meter-25a/"},"ai":{"faq":[{"question":"What is C1036M025 used for?","answer":"It is an electronic trip unit for ComPacT NSX100...250 circuit breakers, designed for motor protection with LSIG functions and selectable tripping classes."},{"question":"Where can I buy C1036M025?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What standards does C1036M025 comply with?","answer":"It complies with EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C1036M025","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C1036M025 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}