{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C1036M080","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C1036M080","canonicalUrl":"https://aoctrl.com/schneider/C1036M080","factsUrl":"https://aoctrl.com/api/mcp/products/C1036M080","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX series, MicroLogic 6.2 E-M electronic trip unit, 80 A at 65 °C, LSIG protection, 3P, EN/IEC 60947-2.","salesMarkdown":"The C1036M080 is a MicroLogic 6.2 E-M electronic trip unit from Schneider Electric's ComPacT NSX100...250 range, designed for motor protection in an AC network. It carries LSIG protection — long-time, short-time, instantaneous, and ground-fault — with an electronic trip unit rated 80 A at 65 °C and a maximum operational voltage of 690 V AC at 50/60 Hz. The 80 A rating at 65 °C (Ir adjustment range 35–80 A) sets the continuous current the trip unit can carry in a warm panel — if your motor FLA is 75 A and ambient hits 65 °C, this unit handles it without derating. The LSIG protection covers overload (L), short-time short-circuit (S) with fixed delay, instantaneous (I) fixed at a multiple of Ir, and ground fault (G). For motor duty, the trip unit supports tripping classes 5, 10, 20, and 30, selectable via the long-time delay adjustment (e.g., 120 s at 1.5 x Ir for class 5, up to 720 s at 1.5 x Ir for class 30). That means you match the thermal curve to the motor's starting profile — a high-inertia load gets class 30 to avoid nuisance trips during start. The short-time pickup (Isd) is adjustable across 9 settings from 5 to 13 x Ir, giving you selectivity headroom downstream. Zone selective interlocking (ZSI) is included — when multiple breakers are daisy-chained, ZSI lets the faulted unit trip instantly while upstream breakers hold, reducing arc-flash energy and keeping the rest of the line running. The LCD display shows energy metering, protection settings, time-stamped events, and maintenance indicators, so you can read trip cause and load data without a laptop. This trip unit mounts into a fixed ComPacT NSX100...250 circuit breaker (3-pole, 3D protected poles). IP40 front-of-panel protection means it's splash-resistant in a standard enclosure, but not washdown-rated. The trip unit communicates protection and metering data — energy, demand values, power quality, max/min readings — so it can feed a BMS or PLC over the breaker's communication bus. No earth-leakage module is included (ground fault is via the LSIG G function, not a separate RCD).","metaTitle":"Schneider Electric C1036M080 MicroLogic 6.2 E-M Trip Unit, 8","metaDescription":"Schneider Electric C1036M080 MicroLogic 6.2 E-M electronic trip unit for ComPacT NSX breakers, 80 A at 65 °C, LSIG protection, EN/IEC 60947-2. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Motor","Display Type":"LCD display","Product Status":"Active","Trip Unit Type":"Electronic","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Trip unit","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$313.73 – $332.55","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/988485171997f8a4d3e085bd24bf7029.pdf","sourceUrl":"https://www.se.com/th/en/product/C1036M080/trip-unit-micrologic-6-2em-compact-nsx100250-3-poles-basic-and-ground-fault-protections-motor-energy-meter-80a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C1036M080/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C1036M080","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C1036M080 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}