{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C1036M080","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C1036M080","canonicalUrl":"https://aoctrl.com/schneider/C1036M080","factsUrl":"https://aoctrl.com/api/mcp/products/C1036M080","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX series, MicroLogic 6.2 E-M electronic trip unit, 80 A at 65 °C, LSIG protection, 3P, EN/IEC 60947-2.","salesMarkdown":"The C1036M080 is a MicroLogic 6.2 E-M electronic trip unit from Schneider Electric's ComPacT NSX100...250 range, designed for motor protection in an AC network. It carries LSIG protection — long-time, short-time, instantaneous, and ground-fault — with an electronic trip unit rated 80 A at 65 °C and a maximum operational voltage of 690 V AC at 50/60 Hz. The 80 A rating at 65 °C (Ir adjustment range 35–80 A) sets the continuous current the trip unit can carry in a warm panel — if your motor FLA is 75 A and ambient hits 65 °C, this unit handles it without derating. The LSIG protection covers overload (L), short-time short-circuit (S) with fixed delay, instantaneous (I) fixed at a multiple of Ir, and ground fault (G). For motor duty, the trip unit supports tripping classes 5, 10, 20, and 30, selectable via the long-time delay adjustment (e.g., 120 s at 1.5 x Ir for class 5, up to 720 s at 1.5 x Ir for class 30). That means you match the thermal curve to the motor's starting profile — a high-inertia load gets class 30 to avoid nuisance trips during start. The short-time pickup (Isd) is adjustable across 9 settings from 5 to 13 x Ir, giving you selectivity headroom downstream. Zone selective interlocking (ZSI) is included — when multiple breakers are daisy-chained, ZSI lets the faulted unit trip instantly while upstream breakers hold, reducing arc-flash energy and keeping the rest of the line running. The LCD display shows energy metering, protection settings, time-stamped events, and maintenance indicators, so you can read trip cause and load data without a laptop. This trip unit mounts into a fixed ComPacT NSX100...250 circuit breaker (3-pole, 3D protected poles). IP40 front-of-panel protection means it's splash-resistant in a standard enclosure, but not washdown-rated. The trip unit communicates protection and metering data — energy, demand values, power quality, max/min readings — so it can feed a BMS or PLC over the breaker's communication bus. No earth-leakage module is included (ground fault is via the LSIG G function, not a separate RCD).","metaTitle":"Schneider Electric C1036M080 MicroLogic 6.2 E-M Trip Unit, 8","metaDescription":"Schneider Electric C1036M080 MicroLogic 6.2 E-M electronic trip unit for ComPacT NSX breakers, 80 A at 65 °C, LSIG protection, EN/IEC 60947-2. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","title":"C1036M080","Standards":"EN/IEC 60947-2","description":"Trip unit MicroLogic 6.2EM, ComPacT NSX100-250, 3 poles, basic and ground fault protections, motor, energy meter, 80A","Display type":"LCD display","Network type":"AC","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 6.2 E-M","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection G : for ground fault protection","lifecycle_stage":"current","Local signalling":"Flashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point","Pollution degree":"3 conforming to IEC 60947-1","Range of product":"ComPacT NSX100...250","Trip unit rating":"80 A at 65 °C","Network frequency":"50/60 Hz","Poles description":"3P","Device application":"Motor","Type of measurement":"Energy meter","Motor tripping class":"10 30 5 20","Trip unit technology":"Electronic","Communication of data":"Energy metering Protection and alarm settings Time-stamped histories and event tables Instantaneous and demand values Maintenance indicators Demand current and power Power quality Maximeters/minimeters","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Electrical data recording":"Maintenance indicators","Product or component type":"Trip unit","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","Complementary motor protection":"Protracted starting time Stalled rotor Current unbalance Underload","Trip unit protection functions":"LSIG","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"With","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"120 s at 1.5 x Ir for trip class 5 6.5 s at 6 x Ir for trip class 5 5 s at 7.2 x Ir for trip class 5 240 s at 1.5 x Ir for trip class 10 13.5 s at 6 x Ir for trip class 10 10 s at 7.2 x Ir for trip class 10 480 s at 1.5 x Ir for trip class 20 26 s at 6 x Ir for trip class 20 20 s at 7.2 x Ir for trip class 20 720 s at 1.5 x Ir for trip class 30","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Ground-fault protection pick-up adjustment type Ig":"Adjustable","[Ir] long-time protection pick-up adjustment range":"35...80 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Isd] Short-time protection pick-up adjustment range":"5...13 x Ir","Ground-fault protection time delay adjustment type tg":"Adjustable","[Ig] ground-fault protection pick-up adjustment range":"0.2...1 x In for In = 50 A Ig enable on/off","[Ii] instantaneous protection pick-up adjustment range":"1200 A","[Tg] Ground-Fault Protection Time Delay Adjustment Range":"0...0.4 s","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$313.73 – $332.55","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/988485171997f8a4d3e085bd24bf7029.pdf","sourceUrl":"https://www.se.com/th/en/product/C1036M080/trip-unit-micrologic-6-2em-compact-nsx100250-3-poles-basic-and-ground-fault-protections-motor-energy-meter-80a/"},"ai":{"faq":[{"question":"What is C1036M080's listed range and standards?","answer":"It belongs to the Schneider Electric ComPacT NSX100...250 range and complies with EN/IEC 60947-2."},{"question":"What protection functions does the MicroLogic 6.2 E-M provide?","answer":"LSIG protection: long-time overload (L), short-time short-circuit with fixed delay (S), instantaneous short-circuit (I), and ground fault (G). Motor tripping classes 5, 10, 20, and 30 are selectable."},{"question":"Where can I buy C1036M080 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C1036M080","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C1036M080 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}