{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C106TM032C","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C106TM032C","canonicalUrl":"https://aoctrl.com/schneider/C106TM032C","factsUrl":"https://aoctrl.com/api/mcp/products/C106TM032C","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX100...250, TM-D trip unit, thermal-magnetic, 32 A at 50 °C, 4 poles 3D, EN/IEC 60947-2.","salesMarkdown":"The C106TM032C is a Schneider Electric ComPacT NSX thermal-magnetic trip unit, rated 32 A at 50 °C, designed for the NSX100...250 frame. It provides LI protection — thermal overload (L) and magnetic short-circuit (I) — in a 4-pole, 3D configuration (three protected poles, neutral unprotected). The instantaneous magnetic pickup is fixed at 400 A, meaning a fault current above that level trips the breaker without intentional delay. The unit carries an IP40 protection rating, suitable for installation inside an enclosed panel where dust ingress is limited. If your panel runs hotter — say 60 °C — you need to derate or step up to a higher amp frame. The long-time pickup (Ir) is adjustable from 0.7 to 1.0 x In (22.4 to 32 A), letting you fine-tune the overload threshold to match the downstream cable or load without swapping the trip unit. The fixed instantaneous pickup at 400 A (12.5 x In) is a deliberate choice: it avoids nuisance tripping on motor inrush or capacitor bank charging current, but it also means the short-circuit protection threshold is not adjustable. For a distribution board feeding mixed loads — lighting, small motors, control transformers — this fixed band is usually fine. If you need a lower Ii for a sensitive branch, look at the TM-D variants with adjustable magnetic pickup. That covers everything from dielectric withstand to temperature rise limits and breaking capacity.","metaTitle":"Schneider C106TM032C ComPacT NSX TM-D Trip Unit, 32 A, 4P","metaDescription":"Schneider Electric C106TM032C ComPacT NSX thermal-magnetic trip unit, 32 A at 50 °C, 4 poles 3D, EN/IEC 60947-2. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"ComPacT","title":"C106TM032C","Standards":"EN/IEC 60947-2","description":"Trip unit TM32D, ComPacT NSX100/160, thermal magnetic, rating 32A, 50 degrees C, 4 poles 3D","Network type":"AC DC","Trip unit name":"TM-D","Protection type":"L : for overload protection (thermal) I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60947-1","Range of product":"ComPacT NSX100...250","Trip unit rating":"32 A at 50 °C","Network frequency":"50/60 Hz","Poles description":"4P","Device application":"Distribution","Trip unit technology":"Thermal-magnetic","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Trip unit","Neutral protection settings":"No protection (3D)","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","Trip unit protection functions":"LI","[Ue] rated operational voltage":"690 V AC 50/60 Hz 750 V DC","Electrical shock protection class":"Class II","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","Long-time protection delay adjustment type tr":"Fixed","[Tr] Long-Time Protection Delay Adjustment Range":"120...400 s at 1.5 x In 15 s at 6 x Ir","[Ir] long-time protection pick-up adjustment range":"0.7...1 x In","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ii] instantaneous protection pick-up adjustment range":"400 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/51c1ae3b07cc3e91a6eefebcad370103.pdf","sourceUrl":"https://www.se.com/nl/en/product/C106TM032C/trip-unit-tm32d-compact-nsx100-160-thermal-magnetic-rating-32a-50-degrees-c-4-poles-3d/"},"ai":{"faq":[{"question":"What are the key ratings of C106TM032C?","answer":"32 A continuous rating at 50 °C, 690 V AC / 750 V DC rated operational voltage, 4 poles with 3 protected poles (3D), fixed instantaneous magnetic pickup at 400 A, and adjustable thermal overload pickup from 0.7 to 1.0 x In."},{"question":"What standard does C106TM032C comply with?","answer":"It is designed and tested to EN/IEC 60947-2, the international standard for low-voltage circuit-breakers used in distribution and motor control."},{"question":"Where can I buy C106TM032C and get current pricing?","answer":"The C106TM032C is sourced to order through independent distribution. Submit an RFQ to get current pricing and availability confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C106TM032C","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C106TM032C when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}