{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10B4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10B4","canonicalUrl":"https://aoctrl.com/schneider/C10B4","factsUrl":"https://aoctrl.com/api/mcp/products/C10B4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX100B basic frame, C10B4, 4P, 100 A at 40 °C, 25 kA Icu at 415 V AC, without trip unit, toggle control, IP40.","salesMarkdown":"The C10B4 is a ComPacT NSX100B basic frame — a 4-pole, 100 A molded-case circuit breaker frame without a trip unit, intended for distribution applications. The Ics (service breaking capacity) at the same voltage is also 25 kA, meaning it can reclose after a fault at full rated current without derating — a practical advantage for selectivity studies. The 8 kV impulse withstand (Uimp) means it survives surge events typical of overvoltage category III environments — think main distribution boards. Once you add a thermal-magnetic or electronic trip unit (sold separately), the actual protection curve is set by that module. ## Deployment and integration Mounts fixed to a backplate (not DIN rail) — the 140 mm width, 161 mm height, and 86 mm depth fit standard ComPacT NSX cutouts. Front connections top and bottom, neutral on the left, 35 mm connection pitch. Toggle control for manual operation. Electrical durability is 30,000 cycles at 440 V AC at In, and 50,000 cycles at In/2. Mechanical durability is 50,000 cycles. That's typical for a distribution-grade MCCB — expect decades of service in a fixed installation with infrequent switching.","metaTitle":"Schneider Electric C10B4 ComPacT NSX100B Basic Frame, 100A,","metaDescription":"Schneider Electric C10B4 ComPacT NSX100B basic frame, 100A rated current, 25kA breaking capacity at 415V AC. Current production. Sourced to order against RFQ. IEC 60947-2, UL 60947","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Protection Type":"Without protection","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"50000 cycles conforming to IEC 60947-2","Connection Surface Bottom":"Front","Main Product Or Component Type":"Basic frame","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$111.17 – $204.78","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ab0e0cac32b48adc64e08652b949f796.pdf","sourceUrl":"https://www.se.com/ae/en/product/C10B4/circuit-breaker-basic-frame-compact-nsx100b-25ka-at-415vac-50-60-hz-100a-without-trip-unit-4-poles/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10B4/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10B4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10B4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}