{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10B42D040","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10B42D040","canonicalUrl":"https://aoctrl.com/schneider/C10B42D040","factsUrl":"https://aoctrl.com/api/mcp/products/C10B42D040","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX100B frame, 40 A, 4P, MicroLogic 2.2 electronic trip unit, 40 kA Icu at 240 V AC, toggle control.","salesMarkdown":"The C10B42D040 is a Schneider Electric ComPacT NSX molded-case circuit breaker in the NSX100B frame, rated 40 A at 40 °C with a MicroLogic 2.2 electronic trip unit. Four poles, toggle control, front-connected — it's built for distribution duty in a backplate-mounted panel. This breaker delivers 40 kA Icu at 220/240 V AC, 25 kA at 380/415 V, 20 kA at 440 V, and 15 kA at 500 V — all per IEC 60947-2. For a 400 V distribution board, that 25 kA Icu gives you headroom above typical utility fault levels (often 18–22 kA), so you can coordinate downstream without cascading failures. The electronic trip also means you get adjustable long-time and short-time pickup — not just a thermal-magnetic fixed curve. Connection pitch is 35 mm, and both line and load connections are front-accessed, so you can land cables without pulling the breaker out of the panel. IP40 enclosure protection keeps dust out but isn't rated for washdown — keep it inside a cabinet.","metaTitle":"C10B42D040 ComPacT NSX 40A 4P MCCB, 40 kA Icu at 240 V","metaDescription":"C10B42D040 ComPacT NSX 100B frame, 40 A MicroLogic 2.2 electronic trip, 4P, 40 kA Icu at 240 V AC. Active production, sourced to order. Quoted against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"140 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Electronic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"800 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical Life Cycles":"50000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$393.00 – $645.73","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/959f38a99f72cd7e8058d2abdcb70ebd.pdf","sourceUrl":"https://www.se.com/hk/en/product/C10B42D040/circuit-breaker-compact-nsx100b-25ka-415vac-4-poles-micrologic-2-2-trip-unit-40a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10B42D040/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10B42D040","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10B42D040 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}