{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10F3TM100C","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10F3TM100C","canonicalUrl":"https://aoctrl.com/schneider/C10F3TM100C","factsUrl":"https://aoctrl.com/api/mcp/products/C10F3TM100C","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX series, NSX100F, 3-pole, 100 A thermal-magnetic trip unit TM-D, 85 kA Icu at 240 V AC, EN/IEC 60947-2.","salesMarkdown":"It's rated to EN/IEC 60947-2, so it's built for distribution-level fault protection in commercial and industrial panels — not a miniature breaker for branch circuits. The TM-D trip gives you fixed thermal overload (L) and magnetic short-circuit (I) protection — no interchangeable rating plugs, no electronic adjustment. If you need adjustable long-time or short-time pickup, you'd be looking at a Micrologic electronic trip instead. Mounts flat on a backplate — no DIN-rail clip. Front connections top and bottom, 35 mm pitch between poles. The toggle handle protrudes; you'll need a standard rotary handle extension if the door closes over it. IP40 front face keeps tools and fingers out, but it's not sealed against hose spray. The ComPacT NSX platform is Schneider's mainstream MCCB line; this variant (NSX100F, 100 A, 3P, TM-D) is a standard catalogue item. For a BOM freeze, this is a stable line — no imminent PCN or LTB expected. That matters for selectivity: if your upstream transformer can deliver 50 kA fault current, this breaker will clear it, but you may lose coordination with a downstream 25 kA MCCB. The utilisation category is A (no intentional short-time delay), so it trips instantaneously on magnetic pickup — fine for feeder protection, not for motor-starting coordination where you need a delayed trip.","metaTitle":"Schneider Electric C10F3TM100C ComPacT NSX100F, 100 A, 3P, 8","metaDescription":"Schneider Electric C10F3TM100C ComPacT NSX100F circuit breaker, 100 A thermal-magnetic, 85 kA Icu at 240 V AC, EN/IEC 60947-2. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Range":"ComPacT","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"105 mm","Height (H)":"161 mm","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSX","Trip unit name":"TM-D","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (thermal) I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"100 A at 50 °C","Breaking capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"NSX100F","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"100 A at 50 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical durability":"50000 cycles","Breaking capacity code":"F 36 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"8.8 W","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Trip unit protection functions":"LI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"120...400 s at 1.5 x In 15 s at 6 x Ir","[Uimp] rated impulse withstand voltage":"8 kV","Long-time protection delay adjustment type tr":"Fixed","[Ir] long-time protection pick-up adjustment range":"0.7...1 x In","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ii] instantaneous protection pick-up adjustment range":"800 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3c78fbee644e941a3069baaa4bf09a3c.pdf","sourceUrl":"https://www.se.com/ae/en/product/C10F3TM100C/circuit-breaker-compact-nsx100f-36ka-at-415vac-tmd-trip-unit-100a-50-degrees-c-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10F3TM100C/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C10F3TM100C at 415 V?","answer":"36 kA Icu at 380/415 V AC, 50/60 Hz, per IEC 60947-2. That's the standard rating for the 'F' breaking capacity code."},{"question":"What compliance documentation does this breaker carry?","answer":"It's certified to EN/IEC 60947-2, with pollution degree 3 per IEC 60664-1 and overvoltage category III. Suitable for isolation per the same standard. IK07 impact resistance and IP40 ingress protection. No earth-leakage protection built in."},{"question":"Where can I buy C10F3TM100C and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no online stock or price listed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10F3TM100C","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10F3TM100C when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}