{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10F47E100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10F47E100","canonicalUrl":"https://aoctrl.com/schneider/C10F47E100","factsUrl":"https://aoctrl.com/api/mcp/products/C10F47E100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX100F, circuit breaker, 100 A at 40 °C, MicroLogic 7.2 E electronic trip unit, 85 kA Icu at 240 V AC, 4P, EN/IEC 60947-2.","salesMarkdown":"## ComPacT NSX100F with MicroLogic 7.2 E — 100 A, 85 kA Icu The Schneider Electric C10F47E100 is a ComPacT NSX100F circuit breaker, part of the ComPacT NSX family, with a MicroLogic 7.2 E electronic trip unit rated 100 A at 40 °C. It delivers 85 kA Icu at 240 V AC and 36 kA Icu at 415 V AC, both conforming to EN/IEC 60947-2. The 4-pole design with toggle control and LCD display is built for distribution applications where earth-leakage protection is required alongside overload, short-time, and instantaneous short-circuit protection. ## Breaking capacity and protection logic The breaking capacity curve covers the full low-voltage range: 85 kA Icu at 220/240 V AC, 36 kA at 380/415 V, 35 kA at 440 V, 25 kA at 500 V, 22 kA at 525 V, and 8 kA at 660/690 V AC. Under UL 60947-4-1, it holds 85 kA at 240 V, 25 kA at 480 V, and 10 kA at 600 V AC. The MicroLogic 7.2 E trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and R (earth-leakage) protection, with an LCD display for local signalling and a flashing green LED for ready status, red LED at 105 % Ir for overload, and orange LED at 90 % Ir. The 4-pole unit occupies 140 mm width, 161 mm height, and 86 mm depth, with a 35 mm connection pitch. ## Communication and metering The MicroLogic 7.2 E trip unit supports energy metering and communication of time-stamped histories, event tables, maintenance indicators, instantaneous and demand values, maximeters/minimeters, protection and alarm settings, power quality data, and demand current and power. Five slots are available for optional communication modules or auxiliaries.","metaTitle":"Schneider Electric C10F47E100 ComPacT NSX100F, 100 A, 85 kA","metaDescription":"Schneider Electric C10F47E100 ComPacT NSX100F circuit breaker. 100 A at 40 °C, MicroLogic 7.2 E trip unit, 85 kA Icu at 240 V AC. EN/IEC 60947-2. Available to order; RFQ for pricin","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"140 mm","Height (H)":"161 mm","Control type":"Toggle","Display type":"LCD display","Network type":"AC","Product name":"ComPacT NSX","Operating mode":"OFF using the IΔn rotary switch","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 7.2 E","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection R : for earth-leakage protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Mounting support":"Backplate","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"100 A at 40 °C","Breaking capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 25 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Device short name":"NSX100F","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"100 A at 40 °C","Downside connection":"Front","Type of measurement":"Energy meter","Overvoltage category":"IV","Trip unit technology":"Electronic","Utilisation category":"Category A","Communication of data":"Time-stamped histories and event tables Maintenance indicators Instantaneous and demand values Maximeters/minimeters Protection and alarm settings Power quality Energy metering Demand current and power","Electrical durability":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical durability":"50000 cycles","Breaking capacity code":"F 36 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Integrated","Product or component type":"Earth leakage circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Neutral protection setting":"0.5 x Ir (3D + N/2) 1 x Ir (4D) No protection (3D)","Power dissipation per pole":"5.8 W N 5.8 W L1 and L3 4.9 W L2","Protected poles description":"4D 3D + OSN 3D + N/2 3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Class A","Trip unit protection functions":"LSIR","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"15...400 s at 1.5 x Ir 0.5...16 s at 6 x Ir 0.35...11 s at 7.2 x Ir","[Uimp] rated impulse withstand voltage":"8 kV","[Tsd] Short-Time Delay Adjustment Range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Adjustable","Short-time protection pick-up adjustment type Isd":"Adjustable","[Ir] long-time protection pick-up adjustment range":"40...100 A","[Δt] residual earth-leakage time delay adjustment":"0 ms 60 ms 150 ms 500 ms 1 s","Instantaneous protection pick-up adjustment type Ii":"Adjustable","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1.5...15 x In","Earth-leakage protection sensitity adjustment type IΔn":"Adjustable","Earth-leakage protection time delay adjustement type Δt":"Adjustable","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings","[IΔn] earth-leakage protection sensitivity adjustment range":"30 mA 100 mA 300 mA 500 mA 1 A 3 A 5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,589.56 – $3,475.44","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6753439c11a98acb91ab216ac17c5cc9.pdf","sourceUrl":"https://www.se.com/vn/en/product/C10F47E100/circuit-breaker-compact-nsx100f-36ka-415vac-4-poles-micrologic-vigi-7-2e-trip-unit-100a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10F47E100/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for C10F47E100?","answer":"Submit an RFQ for the C10F47E100; pricing and availability are confirmed at quote time through independent distribution channels."},{"question":"What is C10F47E100's breaking capacity at 415 V AC?","answer":"The C10F47E100 delivers 36 kA Icu at 380/415 V AC conforming to EN/IEC 60947-2."},{"question":"What compliance documentation does this brand provide for C10F47E100?","answer":"The C10F47E100 is certified to EN/IEC 60947-2 and UL 60947-4-1. It carries pollution degree 3 per IEC 60664-1 and is rated for overvoltage category IV."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10F47E100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10F47E100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}