{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10F6TM016C","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10F6TM016C","canonicalUrl":"https://aoctrl.com/schneider/C10F6TM016C","factsUrl":"https://aoctrl.com/api/mcp/products/C10F6TM016C","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX NSX100F, 16 A, 4P, thermal-magnetic TM-D trip unit, 36 kA Icu at 415 V AC, IP40, toggle control.","salesMarkdown":"The TM-D trip gives you fixed thermal overload (L) and fixed magnetic short-circuit (I) protection; no adjustment dials, so what you order is what protects the circuit. The 4-pole configuration (3 phases + neutral) suits a 3-phase 4-wire system where the neutral is switched. Mounts on a backplate, not a DIN rail — this is a bolted-down MCCB for a panel or enclosure, with front connections top and bottom. The 140 mm width, 161 mm height, and 86 mm depth fit the standard NSX100F cutout. The IK07 impact rating means it withstands a 2 J hammer blow — robust enough for an industrial panel door. ## Compliance and approvals Suitability for isolation is confirmed per that standard — you can use it as a disconnecting means. No earth-leakage protection built in — the TM-D trip handles overload and short-circuit only. If you need ground-fault protection, you add a Vigi module externally. The breaker is rated for horizontal and vertical mounting, flat on the backplate, which gives flexibility in panel layout.","metaTitle":"C10F6TM016C ComPacT NSX100F 16A 4P Circuit Breaker, 36 kA 41","metaDescription":"C10F6TM016C ComPacT NSX100F 16A 4P MCCB. TM-D thermal-magnetic trip. 36 kA Icu at 415V AC. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Range":"ComPacT","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"140 mm","Height (H)":"161 mm","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSX","Trip unit name":"TM-D","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (thermal) I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Backplate","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"16 A at 50 °C","Breaking capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"NSX100F","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"16 A at 50 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical durability":"50000 cycles","Breaking capacity code":"F 36 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Neutral protection setting":"No protection (3D)","Power dissipation per pole":"2.92 W","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Trip unit protection functions":"LI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"120...400 s at 1.5 x In 15 s at 6 x Ir","[Uimp] rated impulse withstand voltage":"8 kV","Long-time protection delay adjustment type tr":"Fixed","[Ir] long-time protection pick-up adjustment range":"0.7...1 x In","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ii] instantaneous protection pick-up adjustment range":"190 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f14b9eaea4c7bb66751b013427aeac55.pdf","sourceUrl":"https://www.se.com/ae/en/product/C10F6TM016C/circuit-breaker-compact-nsx100f-36ka-at-415vac-tmd-trip-unit-16a-50-degrees-c-4-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10F6TM016C/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of C10F6TM016C at 415 V?","answer":"36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. That is the F breaking capacity code — the standard rating for this frame size at 415 V."},{"question":"What does the TM-D trip unit protect against?","answer":"Thermal overload (L) and fixed magnetic short-circuit (I). No adjustment — the thermal element is sized for 16 A at 50 °C, and the magnetic pickup is fixed at a factory-set multiple of In."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10F6TM016C","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10F6TM016C when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}