{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10F6TM040","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10F6TM040","canonicalUrl":"https://aoctrl.com/schneider/C10F6TM040","factsUrl":"https://aoctrl.com/api/mcp/products/C10F6TM040","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX100F, circuit breaker, 40 A, 4P, TM-D trip unit, 85 kA Icu at 240 V AC, 36 kA at 415 V AC.","salesMarkdown":"## What the 40 A TM-D trip unit means for your BOM That 40 A is the full-frame rating for this NSX100F frame, so you get the full interrupting capacity of the frame at this trip size. At 240 V AC it delivers 85 kA Icu — enough for most North American panelboards fed by a large transformer. At 415 V AC, where most European industrial distribution runs, it delivers 36 kA Icu. The breaker is 4-pole (4P) with the neutral on the left. Neutral protection is set to 3D — no protection on the neutral pole, meaning it switches the neutral but does not trip on a neutral overload. That is standard for distribution where the neutral is not expected to carry fault current. The toggle control is manual, no motor operator included. Connections are front-facing on both the line and load sides, which simplifies busbar connections and cable dressing in a panel. ## Durability and electrical life Mechanical durability is 50,000 cycles — the number of on-off operations the mechanism can handle before wear. Electrical durability varies with load: 50,000 cycles at 440 V at half rated current, 30,000 cycles at full 40 A at 440 V, and 10,000 cycles at 690 V at full current. For a distribution breaker that operates infrequently (a few times a year for maintenance isolation), this is more than adequate. For a breaker that cycles daily with a load, the 10,000-cycle figure at 690 V is the limiting factor.","metaTitle":"Schneider Electric C10F6TM040 ComPacT NSX100F 40A MCCB, 85kA","metaDescription":"Schneider Electric C10F6TM040 ComPacT NSX100F 40A thermal-magnetic MCCB. 85 kA Icu at 240 V AC, 36 kA at 415 V. EN/IEC 60947-2. Active production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Range":"ComPacT","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"140 mm","Height (H)":"161 mm","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSX","Trip unit name":"TM-D","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (thermal) I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Backplate","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"40 A at 40 °C","Breaking capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 25 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Device short name":"NSX100F","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"40 A at 40 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical durability":"50000 cycles","Breaking capacity code":"F 36 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Neutral protection setting":"No protection (3D)","Power dissipation per pole":"5.47 W","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Trip unit protection functions":"LI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"120...400 s at 1.5 x In 15 s at 6 x Ir","[Uimp] rated impulse withstand voltage":"8 kV","Long-time protection delay adjustment type tr":"Fixed","[Ir] long-time protection pick-up adjustment range":"0.7...1 x In","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ii] instantaneous protection pick-up adjustment range":"500 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$183.67 – $534.01","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4384eace3f45f515e1a385c065856234.pdf","sourceUrl":"https://www.se.com/nl/en/product/C10F6TM040/circuit-breaker-compact-nsx100f-36ka-415vac-4-poles-3d-neutral-not-protected-tmd-trip-unit-40a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10F6TM040/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the C10F6TM040 at 415 V?","answer":"36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. This is the F breaking capacity code."},{"question":"What is the C10F6TM040's depth?","answer":"86 mm depth, 140 mm width, 161 mm height."},{"question":"What compliance documentation is available for the C10F6TM040?","answer":"The breaker is certified to EN/IEC 60947-2, suitable for isolation per that standard, and rated IP40 per IEC 60529 with IK07 impact protection per IEC 62262."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10F6TM040","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10F6TM040 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}