{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10F6TM080C","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10F6TM080C","canonicalUrl":"https://aoctrl.com/schneider/C10F6TM080C","factsUrl":"https://aoctrl.com/api/mcp/products/C10F6TM080C","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX100F, 4P, 80 A thermal-magnetic TM-D, 36 kA Icu at 415 V AC, toggle control.","salesMarkdown":"It breaks 36 kA Icu at 380/415 V AC per IEC 60947-2, which is the typical line-to-line voltage in European 400 V distribution panels — so it handles fault currents up to that level without upstream fuses needing to open first. The 4-pole construction (3 phases + neutral) with neutral protection set to 3D (no protection) suits it for 3-phase, 4-wire systems where the neutral is a distributed conductor but not separately protected. ## Breaking capacity — what the F code means for your panel At 220/240 V AC it rises to 85 kA Icu; at 690 V AC it drops to 8 kA Icu. For a 400 V distribution board with a transformer of 1.5–2 MVA, 36 kA is typical for main or sub-main breakers. The C10F6TM080C is utilisation category A, meaning it is not intended for motor starting duty (no frequent on-off switching under load). ## Panel integration — dimensions and mounting Mounts on a backplate in any orientation — horizontal, vertical, or flat on the back. Dimensions: 161 mm H × 140 mm W × 86 mm D. Front connections top and bottom. Connection pitch 35 mm. IP40 front face; IK07 impact resistance. Operating altitude 0–2000 m without derating; derate above 2000 m.","metaTitle":"Schneider Electric C10F6TM080C ComPacT NSX100F, 80 A, 36 kA","metaDescription":"Schneider Electric C10F6TM080C ComPacT NSX circuit breaker, 80 A thermal-magnetic TM-D trip unit, 36 kA Icu at 415 V AC per IEC 60947-2. Current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Range":"ComPacT","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"140 mm","Height (H)":"161 mm","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSX","Trip unit name":"TM-D","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (thermal) I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Backplate","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"80 A at 50 °C","Breaking capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"NSX100F","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"80 A at 50 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical durability":"50000 cycles","Breaking capacity code":"F 36 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Neutral protection setting":"No protection (3D)","Power dissipation per pole":"8.77 W","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Trip unit protection functions":"LI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"120...400 s at 1.5 x In 15 s at 6 x Ir","[Uimp] rated impulse withstand voltage":"8 kV","Long-time protection delay adjustment type tr":"Fixed","[Ir] long-time protection pick-up adjustment range":"0.7...1 x In","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ii] instantaneous protection pick-up adjustment range":"640 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a068fe271a84ed39aa02f26bf1f97851.pdf","sourceUrl":"https://www.se.com/ae/en/product/C10F6TM080C/circuit-breaker-compact-nsx100f-36ka-at-415vac-tmd-trip-unit-80a-50-degrees-c-4-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10F6TM080C/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C10F6TM080C and how do I get a price?","answer":"The C10F6TM080C is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time. No stock count or price figure is published here."},{"question":"What is the closest alternative to C10F6TM080C in the ComPacT NSX family?","answer":"The closest alternative within the same frame size is the NSX100N (50 kA Icu at 415 V) or NSX100H (70 kA Icu at 415 V) with the same 80 A TM-D trip unit. The only difference is the interrupting rating — the mounting footprint and connection pitch are identical."},{"question":"What compliance documentation does this brand provide for C10F6TM080C?","answer":"The C10F6TM080C is certified to EN/IEC 60947-2 and carries suitability for isolation per that standard. Pollution degree 3 per IEC 60664-1. IK07 and IP40 per IEC 62262 and IEC 60529. RoHS and REACH compliance documentation is available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10F6TM080C","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10F6TM080C when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}