{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10H32D100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10H32D100","canonicalUrl":"https://aoctrl.com/schneider/C10H32D100","factsUrl":"https://aoctrl.com/api/mcp/products/C10H32D100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX range, NSX100H, 3-pole, 100 A, 70 kA Icu at 415 V AC, MicroLogic 2.2 electronic trip unit, EN/IEC 60947-2.","salesMarkdown":"The C10H32D100 is a Schneider Electric ComPacT NSX100H moulded-case circuit breaker (MCCB) from the ComPacT NSX range, rated 100 A at 40 °C with a MicroLogic 2.2 electronic trip unit. The electronic trip provides L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection, giving you adjustable curves for selective coordination downstream. ## Deployment context Rated IP40 and IK07, so it's suited for clean, dry indoor panel environments — not washdown or outdoor. The ComPacT NSX platform is Schneider's mainstream MCCB line, widely specified and stocked through distribution. Certified to EN/IEC 60947-2, with suitability for isolation per that standard. Overvoltage category III and utilisation category A — standard for distribution circuit breakers in fixed installations. The breaker also carries UL 60947-4-1 ratings at 240 V, 480 V, and 600 V AC, covering North American installations.","metaTitle":"Schneider Electric C10H32D100 ComPacT NSX100H 3P 100A 70kA 4","metaDescription":"Schneider Electric C10H32D100 ComPacT NSX100H circuit breaker, 3 poles, 100 A, 70 kA Icu at 415 V AC, MicroLogic 2.2 electronic trip unit. EN/IEC 60947-2. Active production. Quoted","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"ComPacT","title":"C10H32D100","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"105 mm","Height (H)":"161 mm","description":"Circuit breaker, ComPacT NSX100H, 70kA/415VAC, 3 poles, MicroLogic 2.2 trip unit 100A","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSX","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 2.2","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"100 A at 40 °C","Breaking capacity":"100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Device short name":"NSX100H","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"100 A at 40 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical durability":"50000 cycles","Breaking capacity code":"H 70 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"4.7 W","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Trip unit protection functions":"LSoI","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir","[Uimp] rated impulse withstand voltage":"8 kV","Long-time protection delay adjustment type tr":"Fixed","Short-time protection delay adjustment type tsd":"Fixed","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","[Ir] long-time protection pick-up adjustment range":"40...100 A","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1500 A","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$242.02","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fddba9bf06f8d97ff650cf3f0674602e.pdf","sourceUrl":"https://www.se.com/hk/en/product/C10H32D100/circuit-breaker-compact-nsx100h-70ka-415vac-3-poles-micrologic-2-2-trip-unit-100a/"},"ai":{"faq":[{"question":"What is C10H32D100's breaking capacity at 415 V AC?","answer":"70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. That's the H breaking capacity code in the NSX100H designation."},{"question":"What trip unit does C10H32D100 use?","answer":"It ships with a MicroLogic 2.2 electronic trip unit, providing L (long-time overload), So (short-time short-circuit with fixed delay), and I (instantaneous short-circuit) protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10H32D100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10H32D100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}