{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10H3MA007","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10H3MA007","canonicalUrl":"https://aoctrl.com/schneider/C10H3MA007","factsUrl":"https://aoctrl.com/api/mcp/products/C10H3MA007","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX NSX100H, circuit breaker, 3P, 6.3 A MA magnetic trip unit, 100 kA Icu at 240 V AC, 70 kA at 415 V AC, EN/IEC 60947-2.","salesMarkdown":"The Schneider Electric C10H3MA007 is a ComPacT NSX100H circuit breaker with a magnetic-only MA trip unit rated 6.3 A at 65 °C. It is designed specifically for motor protection — the MA trip provides short-circuit (magnetic) protection only, with no thermal overload element, so it pairs with an external overload relay to handle the motor's running overcurrent protection. The 3-pole device carries a 100 kA Icu breaking capacity at 240 V AC and 70 kA at 415 V AC, both per IEC 60947-2, which means it can safely interrupt fault currents up to those levels without upstream cascading. It also carries UL 60947-4-1 ratings of 85 kA at 240 V and 65 kA at 480 V, covering North American motor branch-circuit installations. If your panel ambient is lower, the breaker can carry slightly more; if higher, you derate. The MA trip unit's magnetic pickup is fixed (not adjustable), so verify the motor's locked-rotor current falls within the breaker's instantaneous trip band. The NSX100H frame accepts plug-in trip units and auxiliary accessories via its 5 accessory slots, so adding shunt trips, aux contacts, or an earth-leakage module later is straightforward. The 105 mm width, 161 mm height, and 86 mm depth fit standard ComPacT NSX cutouts. IK07 impact resistance handles incidental tool contact during maintenance. ## Electrical durability and isolation Rated for 50,000 mechanical cycles and 30,000 electrical cycles at 440 V at rated current. At half-rated current (In/2), electrical durability rises to 50,000 cycles at 440 V and 20,000 cycles at 690 V. Power dissipation is 3.93 W per pole — roughly 12 W total at rated load, which matters for panel thermal calculations.","metaTitle":"Schneider C10H3MA007 ComPacT NSX100H, 6.3 A MA Trip, 100 kA","metaDescription":"Schneider Electric C10H3MA007 ComPacT NSX circuit breaker, 6.3 A magnetic-only MA trip unit, 100 kA Icu at 240 V AC. Motor protection, EN/IEC 60947-2. Available to order against RF","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"ComPacT","title":"C10H3MA007","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"105 mm","Height (H)":"161 mm","description":"Circuit breaker, ComPacT NSX100H, 70kA/415VAC, 3 poles, MA trip unit 6.3A","Control type":"Toggle","Network type":"AC","Product name":"ComPacT NSX","Trip unit name":"MA","Number of slots":"5 slot(s)","Protection type":"I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"6.3 A at 65 °C","Breaking capacity":"100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Device short name":"NSX100H","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Motor protection","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"6.3 A at 65 °C","Downside connection":"Front","Overvoltage category":"III","Trip unit technology":"Magnetic","Utilisation category":"Category A","Electrical durability":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical durability":"50000 cycles","Breaking capacity code":"H 70 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"3.93 W","Protected poles description":"3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","Trip unit protection functions":"I","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV","Short-time protection pick-up adjustment type Isd":"Adjustable 9 settings","Instantaneous protection pick-up adjustment type Ii":"Adjustable 9 settings","[Isd] Short-time protection pick-up adjustment range":"6...14 x In","[Ii] instantaneous protection pick-up adjustment range":"6...14 x In"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$340.07 – $558.95","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ce3b34d64717b161bde64925547cd36b.pdf","sourceUrl":"https://www.se.com/sa/en/product/C10H3MA007/circuit-breaker-compact-nsx100h-70ka-415vac-3-poles-ma-trip-unit-6-3a/"},"ai":{"faq":[{"question":"Where can I buy C10H3MA007 and how do I get a price?","answer":"The C10H3MA007 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is C10H3MA007's listed range on this component line?","answer":"The C10H3MA007 belongs to the Schneider Electric ComPacT range, specifically the ComPacT NSX series."},{"question":"What is C10H3MA007's listed depth?","answer":"The C10H3MA007 has a depth of 86 mm."},{"question":"What compliance documentation does this brand provide for C10H3MA007?","answer":"The C10H3MA007 is certified to EN/IEC 60947-2 and UL 60947-4-1 standards. It carries an IP40 protection rating, IK07 impact rating, and is suitable for isolation per EN/IEC 60947-2. Pollution degree 3 per IEC 60664-1 applies."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10H3MA007","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10H3MA007 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}