{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10H47E040","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10H47E040","canonicalUrl":"https://aoctrl.com/schneider/C10H47E040","factsUrl":"https://aoctrl.com/api/mcp/products/C10H47E040","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX, NSX100H, circuit breaker, 40 A at 40 °C, MicroLogic 7.2 E trip unit, 4P, 100 kA Icu at 240 V AC, EN/IEC 60947-2.","salesMarkdown":"## ComPacT NSX100H with MicroLogic 7.2 E — 40 A, 4P, 100 kA The Schneider Electric C10H47E040 is a ComPacT NSX100H molded-case circuit breaker with a MicroLogic 7.2 E electronic trip unit, rated 40 A at 40 °C. It is a 4-pole unit (4P) with a breaking capacity of 100 kA Icu at 240 V AC, 70 kA at 415 V, and 65 kA at 480 V, all per IEC 60947-2. The electronic trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous), and R (earth-leakage) protection — configurable selectivity for a coordinated distribution system. Mounts on a backplate (mounting support: backplate) in horizontal or vertical orientation, flat on the back. Front connections on both upside and downside simplify bus-bar or cable routing in a panel. The toggle control and LCD display give local status and metering readout without opening the door. At 415 V (common in European industrial grids) it still holds 70 kA, and at 480 V (North American common) it delivers 65 kA. That puts this in the high-interrupting class for a 40 A frame, giving headroom for most distribution panels without needing upstream fuses. The MicroLogic 7.2 E trip unit is electronic, not thermal-magnetic, so it offers adjustable long-time pickup and delay (L), short-time pickup and delay (S), instantaneous pickup (I), and earth-leakage (R) protection. Overvoltage category IV means it's suitable for the main distribution point (utility entrance or main switchboard), not just downstream sub-panels. ## Integration notes Dimensions: 161 mm height, 140 mm width, 86 mm depth. The 35 mm connection pitch matches standard bus-bar spacing for panelboard integration. Five accessory slots allow adding auxiliary contacts, shunt trips, or communication modules without removing the breaker from the panel. The LCD display provides time-stamped event histories, energy metering, demand current and power values, and maintenance indicators — useful for a facility engineer tracking load profiles without a separate power meter.","metaTitle":"Schneider Electric C10H47E040 ComPacT NSX 40A, 100kA at 240V","metaDescription":"Schneider Electric C10H47E040 ComPacT NSX100H circuit breaker. 40A MicroLogic 7.2 E trip unit, 4P, 100 kA Icu at 240 V AC. EN/IEC 60947-2. Currently in production. Available to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Range":"ComPacT","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"140 mm","Height (H)":"161 mm","Control type":"Toggle","Display type":"LCD display","Network type":"AC","Product name":"ComPacT NSX","Operating mode":"OFF using the IΔn rotary switch","Thermal memory":"20 minutes before and after tripping","Trip unit name":"MicroLogic 7.2 E","Number of slots":"5 slot(s)","Protection type":"L : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection R : for earth-leakage protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload","Mounting support":"Backplate","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"40 A at 40 °C","Breaking capacity":"100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1","Device short name":"NSX100H","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"40 A at 40 °C","Downside connection":"Front","Type of measurement":"Energy meter","Overvoltage category":"IV","Trip unit technology":"Electronic","Utilisation category":"Category A","Communication of data":"Time-stamped histories and event tables Maintenance indicators Instantaneous and demand values Maximeters/minimeters Protection and alarm settings Power quality Energy metering Demand current and power","Electrical durability":"50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In","Mechanical durability":"50000 cycles","Breaking capacity code":"H 70 kA 415 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Integrated","Product or component type":"Earth leakage circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Neutral protection setting":"0.5 x Ir (3D + N/2) 1 x Ir (4D) No protection (3D)","Power dissipation per pole":"5.8 W N 5.8 W L1 and L3 4.9 W L2","Protected poles description":"4D 3D + OSN 3D + N/2 3D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Earth-leakage protection class":"Class A","Trip unit protection functions":"LSIR","[Ue] rated operational voltage":"440 V AC 50/60 Hz","Zone selective interlocking ZSI":"Without","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"15...400 s at 1.5 x Ir 0.5...16 s at 6 x Ir 0.35...11 s at 7.2 x Ir","[Uimp] rated impulse withstand voltage":"8 kV","[Tsd] Short-Time Delay Adjustment Range":"0...0.4 s I²t=off 0.1...0.4 s I²t=on","Long-time protection delay adjustment type tr":"Adjustable","Short-time protection delay adjustment type tsd":"Adjustable","Short-time protection pick-up adjustment type Isd":"Adjustable","[Ir] long-time protection pick-up adjustment range":"18...40 A","[Δt] residual earth-leakage time delay adjustment":"0 ms 60 ms 150 ms 500 ms 1 s","Instantaneous protection pick-up adjustment type Ii":"Adjustable","[Isd] Short-time protection pick-up adjustment range":"1.5...10 x Ir","[Ii] instantaneous protection pick-up adjustment range":"1.5...15 x In","Earth-leakage protection sensitity adjustment type IΔn":"Adjustable","Earth-leakage protection time delay adjustement type Δt":"Adjustable","Long-time pick-up adjustment type Ir (thermal protection)":"Adjustable 9 settings","[IΔn] earth-leakage protection sensitivity adjustment range":"30 mA 100 mA 300 mA 500 mA 1 A 3 A 5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,634.18 – $3,652.02","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b1e06d27055a25d6d0f83a2c06576519.pdf","sourceUrl":"https://www.se.com/za/en/product/C10H47E040/circuit-breaker-compact-nsx100h-70ka-415vac-4-poles-micrologic-vigi-7-2e-trip-unit-40a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10H47E040/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy C10H47E040 and how do I get a price?","answer":"The C10H47E040 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing."},{"question":"What is the breaking capacity of C10H47E040 at 415 V?","answer":"The breaking capacity is 70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2."},{"question":"What protection functions does the MicroLogic 7.2 E trip unit provide?","answer":"The MicroLogic 7.2 E provides L (long-time overload), S (short-time short-circuit), I (instantaneous), and R (earth-leakage) protection."},{"question":"What compliance documentation does this brand provide for C10H47E040?","answer":"The breaker complies with EN/IEC 60947-2 and UL 60947-4-1 standards. Specific RoHS/REACH declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10H47E040","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10H47E040 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}