{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10M1TM025","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10M1TM025","canonicalUrl":"https://aoctrl.com/schneider/C10M1TM025","factsUrl":"https://aoctrl.com/api/mcp/products/C10M1TM025","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric ComPacT NSX100M, C10M1TM025, 1-pole 25 A thermal-magnetic circuit breaker, 40 kA Icu at 240 V AC, TM-D trip unit.","salesMarkdown":"The Schneider Electric C10M1TM025 is a ComPacT NSX100M circuit breaker, 1-pole, rated 25 A at 40 °C with a TM-D thermal-magnetic trip unit. The 1P format with toggle control and front connections makes it a direct swap in a fixed-mount panel layout. The TM-D trip provides L (thermal overload) and I (magnetic short-circuit) protection — the thermal element handles sustained overloads, the magnetic element trips instantaneously on high faults. Overvoltage category IV confirms it's suitable for main distribution panels at the service entrance, not just downstream sub-panels. The IP40 enclosure protection keeps out tools and small objects but not water; mount it inside a sealed cabinet for washdown areas. Mechanical durability of 20,000 cycles and electrical durability of 20,000 cycles at 277 V at half rated current (In/2) or 10,000 cycles at full rated current give a realistic service life for a distribution breaker — it's not a motor-switching contactor, but it handles occasional load-break operations without accelerated wear. Fixed-mount on a backplate, 35 mm width per pole, 161 mm height, 86 mm depth.","metaTitle":"Schneider Electric C10M1TM025 ComPacT NSX100M, 25 A, 1P, 40","metaDescription":"Schneider Electric C10M1TM025 ComPacT NSX circuit breaker, 25 A thermal-magnetic TM-D trip unit, 1-pole, 40 kA Icu at 240 V AC. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"ComPacT","title":"C10M1TM025","Depth (D)":"86 mm","Standards":"EN/IEC 60947-2","Width (W)":"35 mm","Height (H)":"161 mm","description":"Circuit breaker, ComPacT NSX100M AC/DC, 40kA/240VAC, 1 pole, TMD trip unit 25A","Control type":"Toggle","Network type":"AC DC","Product name":"ComPacT NSX","Trip unit name":"TM-D","Protection type":"L : for overload protection (thermal) I : for short-circuit protection (magnetic)","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60664-1","Trip unit rating":"25 A at 40 °C","Breaking capacity":"40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 250 V DC conforming to IEC 60947-2","Device short name":"NSX100M","Mounting position":"Horizontal and vertical Flat on the back","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"0...95 %","Upside connection":"Front","Device application":"Distribution","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"25 A at 40 °C","Downside connection":"Front","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"20000 cycles at 277 V In/2 10000 cycles at 277 V In","Mechanical durability":"20000 cycles","Breaking capacity code":"M 40 kA 240 V AC","IK degree of protection":"IK07 conforming to IEC 62262","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"Without","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"4.01 W","Protected poles description":"1D","Circuit breaker mounting mode":"Fixed","[Ui] rated insulation voltage":"750 V AC 50/60 Hz conforming to IEC 60947-2","Trip unit protection functions":"LI","[Ue] rated operational voltage":"277 V AC 50/60 Hz 250 V DC","Electrical shock protection class":"Class II on front face","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 250 V DC conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","Long-time protection delay adjustment type tr":"Fixed","[Ir] long-time protection pick-up adjustment range":"1 x In","Instantaneous protection pick-up adjustment type Ii":"Fixed","[Ii] instantaneous protection pick-up adjustment range":"300 A","Long-time pick-up adjustment type Ir (thermal protection)":"Fixed"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2.52","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/30b2bddf48af336ebc8eb27a39eb1687.pdf","sourceUrl":"https://www.se.com/au/en/product/C10M1TM025/circuit-breaker-compact-nsx100m-ac-dc-40ka-240vac-1-pole-tmd-trip-unit-25a/"},"ai":{"faq":[{"question":"Where can I buy C10M1TM025 and how is it quoted?","answer":"The C10M1TM025 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of C10M1TM025?","answer":"The C10M1TM025 has a breaking capacity of 40 kA Icu at 240 V AC (IEC 60947-2) and 85 kA Icu at 250 V DC."},{"question":"What standards does C10M1TM025 comply with?","answer":"The C10M1TM025 complies with EN/IEC 60947-2 and is suitable for isolation per that standard. It also meets pollution degree 3 (IEC 60664-1) and overvoltage category IV."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10M1TM025","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10M1TM025 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}