{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"C10M2TM030","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"C10M2TM030","canonicalUrl":"https://aoctrl.com/schneider/C10M2TM030","factsUrl":"https://aoctrl.com/api/mcp/products/C10M2TM030","rawCanonicalId":null},"summary":{"shortDescription":"Schneider C10M2TM030 Compact Nsx, New Generation — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.","salesMarkdown":"## Overview Its breaking capacity reaches 85 kA ICu at 690 V AC/DC, making it suitable for distribution applications requiring high fault current interruption. The unit is fixed-mounted with toggle control and complies with EN/IEC 60947-2. The C10M2TM030 remains in active production as part of the ComPacT NSX new generation line. Sourcing is straightforward via RFQ; lead times are typically quoted per enquiry. For BOMs specifying a 3-pole breaker, the C10F3TM025 (3-pole, 25 A, 85 kA) is a functional peer within the same series, though the pole count and amp rating differ — the C10M2TM030 is the correct choice when the design requires exactly 2 poles and 30 A.","metaTitle":"Schneider C10M2TM030 ComPacT NSX MCCB, 2-pole, 30 A, 85 kA","metaDescription":"Schneider ComPacT NSX C10M2TM030 molded case circuit breaker, 2-pole, 30 A TM-D trip, 85 kA ICu at 690 V AC/DC, EN/IEC 60947-2. Active, sourced via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"86 mm","Width":"70 mm","Height":"161 mm","Voltage":"690 V AC 50/60 Hz 500 V DC","IP Rating":"IP40","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"class 3","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz 1P conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz 1P conforming to IEC 60947-2 18 kA Icu at 500/525 V AC 50/60 Hz 2P conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 250 V DC 50/60 Hz 1 pole conforming to IEC 60947-2 85 kA Icu at 500 V DC 50/60 Hz 2 poles in series conforming to IEC 60947-2","Insulation Voltage Ui":"750 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"20000 cycles at 277 V In/2 10000 cycles at 277 V In","Mechanical Life Cycles":"20000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$126.01 – $202.77","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a21397dcc598d0ed87fa752eee014d28.pdf","sourceUrl":"https://www.se.com/ng/en/product/C10M2TM030/circuit-breaker-compact-nsx100m-ac-dc-25ka-at-415vac-tmd-trip-unit-30a-2-poles-2d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/C10M2TM030/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/C10M2TM030","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/C10M2TM030 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}